Cargando…

Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation

Inclination of the subtalar joint (STJ) in the sagittal and transverse planes may be highly associated with ankle pathology. However, the validity and reliability of measuring the inclination of the STJ axis of rotation (AoR) is not well established. This study aimed to develop a custom-made STJ loc...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Byong Hun, Lee, Sae Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8160632/
https://www.ncbi.nlm.nih.gov/pubmed/34065532
http://dx.doi.org/10.3390/ijerph18105494
_version_ 1783700323927326720
author Kim, Byong Hun
Lee, Sae Yong
author_facet Kim, Byong Hun
Lee, Sae Yong
author_sort Kim, Byong Hun
collection PubMed
description Inclination of the subtalar joint (STJ) in the sagittal and transverse planes may be highly associated with ankle pathology. However, the validity and reliability of measuring the inclination of the STJ axis of rotation (AoR) is not well established. This study aimed to develop a custom-made STJ locator (STJL) and evaluate its reliability and validity. To establish the reliability and validity of the measurement device for STJ AoR, 38 healthy male participants were recruited. For the reliability analysis, test–retest was used, and for validity analysis, Pearson’s correlation and Bland–Altman plot analyses were performed. In the reliability analysis of the STJL, a higher correlation was observed with the sagittal plane (0.930) and transverse plane (0.748) (standard error of measurement: 0.56–0.78; minimal detectable difference: 1.57–2.16). In the validity analysis between radiography and STJL, a significantly higher value of 0.798 was obtained with radiography (42.5) and STJL (43.5) with the sagittal plane. The custom-made STJL may be used in the clinical setting as its validity and intraclass correlation coefficient were high, indicating consistent measurements. Further studies including motion analysis are necessary to provide more information regarding the relationship between STJ AoR inclinations and STJ movements.
format Online
Article
Text
id pubmed-8160632
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81606322021-05-29 Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation Kim, Byong Hun Lee, Sae Yong Int J Environ Res Public Health Article Inclination of the subtalar joint (STJ) in the sagittal and transverse planes may be highly associated with ankle pathology. However, the validity and reliability of measuring the inclination of the STJ axis of rotation (AoR) is not well established. This study aimed to develop a custom-made STJ locator (STJL) and evaluate its reliability and validity. To establish the reliability and validity of the measurement device for STJ AoR, 38 healthy male participants were recruited. For the reliability analysis, test–retest was used, and for validity analysis, Pearson’s correlation and Bland–Altman plot analyses were performed. In the reliability analysis of the STJL, a higher correlation was observed with the sagittal plane (0.930) and transverse plane (0.748) (standard error of measurement: 0.56–0.78; minimal detectable difference: 1.57–2.16). In the validity analysis between radiography and STJL, a significantly higher value of 0.798 was obtained with radiography (42.5) and STJL (43.5) with the sagittal plane. The custom-made STJL may be used in the clinical setting as its validity and intraclass correlation coefficient were high, indicating consistent measurements. Further studies including motion analysis are necessary to provide more information regarding the relationship between STJ AoR inclinations and STJ movements. MDPI 2021-05-20 /pmc/articles/PMC8160632/ /pubmed/34065532 http://dx.doi.org/10.3390/ijerph18105494 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Byong Hun
Lee, Sae Yong
Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation
title Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation
title_full Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation
title_fullStr Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation
title_full_unstemmed Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation
title_short Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation
title_sort validity and reliability of a novel instrument for the measurement of subtalar joint axis of rotation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8160632/
https://www.ncbi.nlm.nih.gov/pubmed/34065532
http://dx.doi.org/10.3390/ijerph18105494
work_keys_str_mv AT kimbyonghun validityandreliabilityofanovelinstrumentforthemeasurementofsubtalarjointaxisofrotation
AT leesaeyong validityandreliabilityofanovelinstrumentforthemeasurementofsubtalarjointaxisofrotation