Cargando…

Feasibility Study and Experimental Evaluation of the Design of Nodule Prototype Developed for Palpation Display Apparatus: A Novel Device for Contactless Primary Tactile Diagnosis

Background: Lack of feasible palpation display for primary diagnosis of a tumor without any need of physician to patient physical contact has been reported as one of the major concerns. To further explore this area, we developed a novel palpation device consisting of a uniquely designed nodule mecha...

Descripción completa

Detalles Bibliográficos
Autores principales: Sikander, Sakura, Biswas, Pradipta, Song, Sang-Eun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8160851/
https://www.ncbi.nlm.nih.gov/pubmed/34069631
http://dx.doi.org/10.3390/mi12050576
_version_ 1783700376894046208
author Sikander, Sakura
Biswas, Pradipta
Song, Sang-Eun
author_facet Sikander, Sakura
Biswas, Pradipta
Song, Sang-Eun
author_sort Sikander, Sakura
collection PubMed
description Background: Lack of feasible palpation display for primary diagnosis of a tumor without any need of physician to patient physical contact has been reported as one of the major concerns. To further explore this area, we developed a novel palpation device consisting of a uniquely designed nodule mechanism (based on optimizing nodule top and bottom hemisphere wall thickness and manipulating granular jamming method) that can vary stiffness while maintaining the shape of the same nodule display, for which current devices are not capable of in terms of aping a tumor. Methods: This paper evaluates the manufacturing approach of the nodule, exploring several iterations of the nodule prototype. Experiments were performed on nodule prototypes of varying wall thicknesses in order to evaluate its effect on stiffness and deformation. Results and Conclusions: Experimental results showed that nodule top and bottom wall thickness had a significant effect on the stiffness and deformation of the nodule. The higher the thickness of the top hemisphere and the lower the thickness of the bottom hemisphere, the greater the stiffness the nodule can achieve. Similarly, the display shape of the nodule can be maintained with minimal or no deformation if the nodule top hemisphere thickness is optimally higher than bottom hemisphere thickness.
format Online
Article
Text
id pubmed-8160851
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81608512021-05-29 Feasibility Study and Experimental Evaluation of the Design of Nodule Prototype Developed for Palpation Display Apparatus: A Novel Device for Contactless Primary Tactile Diagnosis Sikander, Sakura Biswas, Pradipta Song, Sang-Eun Micromachines (Basel) Article Background: Lack of feasible palpation display for primary diagnosis of a tumor without any need of physician to patient physical contact has been reported as one of the major concerns. To further explore this area, we developed a novel palpation device consisting of a uniquely designed nodule mechanism (based on optimizing nodule top and bottom hemisphere wall thickness and manipulating granular jamming method) that can vary stiffness while maintaining the shape of the same nodule display, for which current devices are not capable of in terms of aping a tumor. Methods: This paper evaluates the manufacturing approach of the nodule, exploring several iterations of the nodule prototype. Experiments were performed on nodule prototypes of varying wall thicknesses in order to evaluate its effect on stiffness and deformation. Results and Conclusions: Experimental results showed that nodule top and bottom wall thickness had a significant effect on the stiffness and deformation of the nodule. The higher the thickness of the top hemisphere and the lower the thickness of the bottom hemisphere, the greater the stiffness the nodule can achieve. Similarly, the display shape of the nodule can be maintained with minimal or no deformation if the nodule top hemisphere thickness is optimally higher than bottom hemisphere thickness. MDPI 2021-05-19 /pmc/articles/PMC8160851/ /pubmed/34069631 http://dx.doi.org/10.3390/mi12050576 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sikander, Sakura
Biswas, Pradipta
Song, Sang-Eun
Feasibility Study and Experimental Evaluation of the Design of Nodule Prototype Developed for Palpation Display Apparatus: A Novel Device for Contactless Primary Tactile Diagnosis
title Feasibility Study and Experimental Evaluation of the Design of Nodule Prototype Developed for Palpation Display Apparatus: A Novel Device for Contactless Primary Tactile Diagnosis
title_full Feasibility Study and Experimental Evaluation of the Design of Nodule Prototype Developed for Palpation Display Apparatus: A Novel Device for Contactless Primary Tactile Diagnosis
title_fullStr Feasibility Study and Experimental Evaluation of the Design of Nodule Prototype Developed for Palpation Display Apparatus: A Novel Device for Contactless Primary Tactile Diagnosis
title_full_unstemmed Feasibility Study and Experimental Evaluation of the Design of Nodule Prototype Developed for Palpation Display Apparatus: A Novel Device for Contactless Primary Tactile Diagnosis
title_short Feasibility Study and Experimental Evaluation of the Design of Nodule Prototype Developed for Palpation Display Apparatus: A Novel Device for Contactless Primary Tactile Diagnosis
title_sort feasibility study and experimental evaluation of the design of nodule prototype developed for palpation display apparatus: a novel device for contactless primary tactile diagnosis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8160851/
https://www.ncbi.nlm.nih.gov/pubmed/34069631
http://dx.doi.org/10.3390/mi12050576
work_keys_str_mv AT sikandersakura feasibilitystudyandexperimentalevaluationofthedesignofnoduleprototypedevelopedforpalpationdisplayapparatusanoveldeviceforcontactlessprimarytactilediagnosis
AT biswaspradipta feasibilitystudyandexperimentalevaluationofthedesignofnoduleprototypedevelopedforpalpationdisplayapparatusanoveldeviceforcontactlessprimarytactilediagnosis
AT songsangeun feasibilitystudyandexperimentalevaluationofthedesignofnoduleprototypedevelopedforpalpationdisplayapparatusanoveldeviceforcontactlessprimarytactilediagnosis