Cargando…

Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications

Titanium alloys are widely used for biomedical applications due to their good biocompatibility. Nevertheless, they cannot be used for balloon expandable stents due to a lack of ductility compared to cobalt-chromium (Co-Cr) alloys and stainless steels. In this study, a new highly deformable Ti-16Nb-8...

Descripción completa

Detalles Bibliográficos
Autores principales: Ion, Raluca, Cabon, Gaëtan, Gordin, Doina-Margareta, Ionica, Elena, Gloriant, Thierry, Cimpean, Anisoara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8162573/
https://www.ncbi.nlm.nih.gov/pubmed/34068852
http://dx.doi.org/10.3390/jfb12020033
_version_ 1783700744184004608
author Ion, Raluca
Cabon, Gaëtan
Gordin, Doina-Margareta
Ionica, Elena
Gloriant, Thierry
Cimpean, Anisoara
author_facet Ion, Raluca
Cabon, Gaëtan
Gordin, Doina-Margareta
Ionica, Elena
Gloriant, Thierry
Cimpean, Anisoara
author_sort Ion, Raluca
collection PubMed
description Titanium alloys are widely used for biomedical applications due to their good biocompatibility. Nevertheless, they cannot be used for balloon expandable stents due to a lack of ductility compared to cobalt-chromium (Co-Cr) alloys and stainless steels. In this study, a new highly deformable Ti-16Nb-8Mo alloy was designed for such an application. However, the biological performance of a stent material is strongly influenced by the effect exerted on the behavior of endothelial cells. Therefore, the cellular responses of human umbilical vein endothelial cells (HUVECs), including morphological characteristics, cell viability and proliferation, and functional markers expression, were investigated to evaluate the biocompatibility of the alloy in the present study. The in vitro results demonstrated the suitability of this alloy for use as endovascular stents.
format Online
Article
Text
id pubmed-8162573
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81625732021-05-29 Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications Ion, Raluca Cabon, Gaëtan Gordin, Doina-Margareta Ionica, Elena Gloriant, Thierry Cimpean, Anisoara J Funct Biomater Article Titanium alloys are widely used for biomedical applications due to their good biocompatibility. Nevertheless, they cannot be used for balloon expandable stents due to a lack of ductility compared to cobalt-chromium (Co-Cr) alloys and stainless steels. In this study, a new highly deformable Ti-16Nb-8Mo alloy was designed for such an application. However, the biological performance of a stent material is strongly influenced by the effect exerted on the behavior of endothelial cells. Therefore, the cellular responses of human umbilical vein endothelial cells (HUVECs), including morphological characteristics, cell viability and proliferation, and functional markers expression, were investigated to evaluate the biocompatibility of the alloy in the present study. The in vitro results demonstrated the suitability of this alloy for use as endovascular stents. MDPI 2021-05-14 /pmc/articles/PMC8162573/ /pubmed/34068852 http://dx.doi.org/10.3390/jfb12020033 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ion, Raluca
Cabon, Gaëtan
Gordin, Doina-Margareta
Ionica, Elena
Gloriant, Thierry
Cimpean, Anisoara
Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications
title Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications
title_full Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications
title_fullStr Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications
title_full_unstemmed Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications
title_short Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications
title_sort endothelial cell responses to a highly deformable titanium alloy designed for vascular stent applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8162573/
https://www.ncbi.nlm.nih.gov/pubmed/34068852
http://dx.doi.org/10.3390/jfb12020033
work_keys_str_mv AT ionraluca endothelialcellresponsestoahighlydeformabletitaniumalloydesignedforvascularstentapplications
AT cabongaetan endothelialcellresponsestoahighlydeformabletitaniumalloydesignedforvascularstentapplications
AT gordindoinamargareta endothelialcellresponsestoahighlydeformabletitaniumalloydesignedforvascularstentapplications
AT ionicaelena endothelialcellresponsestoahighlydeformabletitaniumalloydesignedforvascularstentapplications
AT gloriantthierry endothelialcellresponsestoahighlydeformabletitaniumalloydesignedforvascularstentapplications
AT cimpeananisoara endothelialcellresponsestoahighlydeformabletitaniumalloydesignedforvascularstentapplications