Cargando…

Comparison of IDEXX SediVue Dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine

BACKGROUND: Detection of urinary casts is difficult due to their intermittent presence and deterioration in urine samples. OBJECTIVE: To compare the performance of the IDEXX SediVue Dx(®) Urine Sediment Analyzer (SediVue) with manual microscopy for the detection of urinary casts. We hypothesized tha...

Descripción completa

Detalles Bibliográficos
Autores principales: Vasilatis, Demitria M., Cowgill, Larry D., Farace, Giosi, Peterson, Sarah, Yerramilli, Murthy, Owens, Sean D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8162614/
https://www.ncbi.nlm.nih.gov/pubmed/33760275
http://dx.doi.org/10.1111/jvim.16090
_version_ 1783700753720803328
author Vasilatis, Demitria M.
Cowgill, Larry D.
Farace, Giosi
Peterson, Sarah
Yerramilli, Murthy
Owens, Sean D.
author_facet Vasilatis, Demitria M.
Cowgill, Larry D.
Farace, Giosi
Peterson, Sarah
Yerramilli, Murthy
Owens, Sean D.
author_sort Vasilatis, Demitria M.
collection PubMed
description BACKGROUND: Detection of urinary casts is difficult due to their intermittent presence and deterioration in urine samples. OBJECTIVE: To compare the performance of the IDEXX SediVue Dx(®) Urine Sediment Analyzer (SediVue) with manual microscopy for the detection of urinary casts. We hypothesized that the SediVue analyzer would perform similarly to manual microscopy in cast detection. ANIMALS: Four hundred forty‐three samples from 420 dogs from a hospital population. METHODS: This is a prospective, cross‐sectional study. For SediVue analysis (software version [SW] 1.0.1.3), uncentrifuged urine was pipetted into a disposable cartridge. Seventy images were captured and processed by an onboard algorithm. For manual microscopy, urine was centrifuged to obtain sediment. Any cast identified by either method was considered a positive result (>0/low‐power field [LPF]). SediVue images were evaluated if casts were detected by either methodology. A revised sensitivity and specificity were calculated after image review and when using a threshold of >1 cast/LPF. RESULTS: The sensitivity of the SediVue analysis for the detection of urinary casts was 53.7% (43.85%‐63.35%), and specificity was 86.0% (81.78%‐89.51%). After image review, the revised sensitivity/specificity was 52.0% (42.89%‐61.02%) and 90.6% (86.81%‐93.54%), respectively. When using a more clinically relevant threshold of >1/LPF, the sensitivity was 52.6% (35.82%‐69.02%) and specificity was 99.3% (97.85%‐99.85%). CONCLUSIONS AND CLINICAL IMPORTANCE: The SediVue provides moderate agreement to manual methodology for detection of casts in urine.
format Online
Article
Text
id pubmed-8162614
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-81626142021-06-03 Comparison of IDEXX SediVue Dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine Vasilatis, Demitria M. Cowgill, Larry D. Farace, Giosi Peterson, Sarah Yerramilli, Murthy Owens, Sean D. J Vet Intern Med SMALL ANIMAL BACKGROUND: Detection of urinary casts is difficult due to their intermittent presence and deterioration in urine samples. OBJECTIVE: To compare the performance of the IDEXX SediVue Dx(®) Urine Sediment Analyzer (SediVue) with manual microscopy for the detection of urinary casts. We hypothesized that the SediVue analyzer would perform similarly to manual microscopy in cast detection. ANIMALS: Four hundred forty‐three samples from 420 dogs from a hospital population. METHODS: This is a prospective, cross‐sectional study. For SediVue analysis (software version [SW] 1.0.1.3), uncentrifuged urine was pipetted into a disposable cartridge. Seventy images were captured and processed by an onboard algorithm. For manual microscopy, urine was centrifuged to obtain sediment. Any cast identified by either method was considered a positive result (>0/low‐power field [LPF]). SediVue images were evaluated if casts were detected by either methodology. A revised sensitivity and specificity were calculated after image review and when using a threshold of >1 cast/LPF. RESULTS: The sensitivity of the SediVue analysis for the detection of urinary casts was 53.7% (43.85%‐63.35%), and specificity was 86.0% (81.78%‐89.51%). After image review, the revised sensitivity/specificity was 52.0% (42.89%‐61.02%) and 90.6% (86.81%‐93.54%), respectively. When using a more clinically relevant threshold of >1/LPF, the sensitivity was 52.6% (35.82%‐69.02%) and specificity was 99.3% (97.85%‐99.85%). CONCLUSIONS AND CLINICAL IMPORTANCE: The SediVue provides moderate agreement to manual methodology for detection of casts in urine. John Wiley & Sons, Inc. 2021-03-24 2021 /pmc/articles/PMC8162614/ /pubmed/33760275 http://dx.doi.org/10.1111/jvim.16090 Text en © 2021 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals LLC on behalf of American College of Veterinary Internal Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle SMALL ANIMAL
Vasilatis, Demitria M.
Cowgill, Larry D.
Farace, Giosi
Peterson, Sarah
Yerramilli, Murthy
Owens, Sean D.
Comparison of IDEXX SediVue Dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine
title Comparison of IDEXX SediVue Dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine
title_full Comparison of IDEXX SediVue Dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine
title_fullStr Comparison of IDEXX SediVue Dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine
title_full_unstemmed Comparison of IDEXX SediVue Dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine
title_short Comparison of IDEXX SediVue Dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine
title_sort comparison of idexx sedivue dx(®) urine sediment analyzer to manual microscopy for detection of casts in canine urine
topic SMALL ANIMAL
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8162614/
https://www.ncbi.nlm.nih.gov/pubmed/33760275
http://dx.doi.org/10.1111/jvim.16090
work_keys_str_mv AT vasilatisdemitriam comparisonofidexxsedivuedxurinesedimentanalyzertomanualmicroscopyfordetectionofcastsincanineurine
AT cowgilllarryd comparisonofidexxsedivuedxurinesedimentanalyzertomanualmicroscopyfordetectionofcastsincanineurine
AT faracegiosi comparisonofidexxsedivuedxurinesedimentanalyzertomanualmicroscopyfordetectionofcastsincanineurine
AT petersonsarah comparisonofidexxsedivuedxurinesedimentanalyzertomanualmicroscopyfordetectionofcastsincanineurine
AT yerramillimurthy comparisonofidexxsedivuedxurinesedimentanalyzertomanualmicroscopyfordetectionofcastsincanineurine
AT owensseand comparisonofidexxsedivuedxurinesedimentanalyzertomanualmicroscopyfordetectionofcastsincanineurine