Cargando…

Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations

BACKGROUND: The FreeStyle Libre (Abbott Laboratories) is a flash glucose monitoring system (FGMS) that measures interstitial glucose concentration (IG). The system is factory‐calibrated, easy to use, inexpensive, and could be useful for monitoring diabetic cats. OBJECTIVES: To evaluate the analytica...

Descripción completa

Detalles Bibliográficos
Autores principales: Del Baldo, Francesca, Fracassi, Federico, Pires, Jully, Tardo, Antonio Maria, Malerba, Eleonora, Manassero, Elisa, Gilor, Chen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8163110/
https://www.ncbi.nlm.nih.gov/pubmed/33991129
http://dx.doi.org/10.1111/jvim.16122
_version_ 1783700835915530240
author Del Baldo, Francesca
Fracassi, Federico
Pires, Jully
Tardo, Antonio Maria
Malerba, Eleonora
Manassero, Elisa
Gilor, Chen
author_facet Del Baldo, Francesca
Fracassi, Federico
Pires, Jully
Tardo, Antonio Maria
Malerba, Eleonora
Manassero, Elisa
Gilor, Chen
author_sort Del Baldo, Francesca
collection PubMed
description BACKGROUND: The FreeStyle Libre (Abbott Laboratories) is a flash glucose monitoring system (FGMS) that measures interstitial glucose concentration (IG). The system is factory‐calibrated, easy to use, inexpensive, and could be useful for monitoring diabetic cats. OBJECTIVES: To evaluate the analytical and clinical accuracy of the FGMS in cats and establish the lag‐time between IG and blood glucose concentration (BG). ANIMALS: Twenty client‐owned diabetic cats and 7 purpose‐bred healthy cats. METHODS: Prospective study. Blood glucose concentration was measured using a portable glucose meter validated for use in cats that served as a reference method for IG, as measured by FGMS. In diabetic cats, data were collected for sensor wearing time with different methods of application and accuracy across glycemic ranges. Accuracy was determined by fulfillment of ISO15197:2013 criteria. In healthy cats, lag‐time between IG and BG was established after IV administration of exogenous glucose. RESULTS: Good agreement between IG and BG was obtained (r = .93). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% of the results in zones A + B of the Parkes consensus error grid analysis. In the immediate 30 minutes after an IV bolus of glucose, when BG was increasing rapidly (approximately 2%/min), IG increased slowly, resulting in a difference of as much as 579 mg/dL, and no positive correlation between BG and IG was found. CONCLUSIONS AND CLINICAL IMPORTANCE: The FGMS did not fulfill ISO requirements but is sufficiently accurate for glucose monitoring in cats, while considering the lag between IG and BG during periods of rapid changes in BG.
format Online
Article
Text
id pubmed-8163110
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-81631102021-06-03 Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations Del Baldo, Francesca Fracassi, Federico Pires, Jully Tardo, Antonio Maria Malerba, Eleonora Manassero, Elisa Gilor, Chen J Vet Intern Med SMALL ANIMAL BACKGROUND: The FreeStyle Libre (Abbott Laboratories) is a flash glucose monitoring system (FGMS) that measures interstitial glucose concentration (IG). The system is factory‐calibrated, easy to use, inexpensive, and could be useful for monitoring diabetic cats. OBJECTIVES: To evaluate the analytical and clinical accuracy of the FGMS in cats and establish the lag‐time between IG and blood glucose concentration (BG). ANIMALS: Twenty client‐owned diabetic cats and 7 purpose‐bred healthy cats. METHODS: Prospective study. Blood glucose concentration was measured using a portable glucose meter validated for use in cats that served as a reference method for IG, as measured by FGMS. In diabetic cats, data were collected for sensor wearing time with different methods of application and accuracy across glycemic ranges. Accuracy was determined by fulfillment of ISO15197:2013 criteria. In healthy cats, lag‐time between IG and BG was established after IV administration of exogenous glucose. RESULTS: Good agreement between IG and BG was obtained (r = .93). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% of the results in zones A + B of the Parkes consensus error grid analysis. In the immediate 30 minutes after an IV bolus of glucose, when BG was increasing rapidly (approximately 2%/min), IG increased slowly, resulting in a difference of as much as 579 mg/dL, and no positive correlation between BG and IG was found. CONCLUSIONS AND CLINICAL IMPORTANCE: The FGMS did not fulfill ISO requirements but is sufficiently accurate for glucose monitoring in cats, while considering the lag between IG and BG during periods of rapid changes in BG. John Wiley & Sons, Inc. 2021-05-15 2021 /pmc/articles/PMC8163110/ /pubmed/33991129 http://dx.doi.org/10.1111/jvim.16122 Text en © 2021 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals LLC on behalf of American College of Veterinary Internal Medicine. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle SMALL ANIMAL
Del Baldo, Francesca
Fracassi, Federico
Pires, Jully
Tardo, Antonio Maria
Malerba, Eleonora
Manassero, Elisa
Gilor, Chen
Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
title Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
title_full Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
title_fullStr Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
title_full_unstemmed Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
title_short Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
title_sort accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
topic SMALL ANIMAL
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8163110/
https://www.ncbi.nlm.nih.gov/pubmed/33991129
http://dx.doi.org/10.1111/jvim.16122
work_keys_str_mv AT delbaldofrancesca accuracyofaflashglucosemonitoringsystemincatsanddeterminationofthetimelagbetweenbloodglucoseandinterstitialglucoseconcentrations
AT fracassifederico accuracyofaflashglucosemonitoringsystemincatsanddeterminationofthetimelagbetweenbloodglucoseandinterstitialglucoseconcentrations
AT piresjully accuracyofaflashglucosemonitoringsystemincatsanddeterminationofthetimelagbetweenbloodglucoseandinterstitialglucoseconcentrations
AT tardoantoniomaria accuracyofaflashglucosemonitoringsystemincatsanddeterminationofthetimelagbetweenbloodglucoseandinterstitialglucoseconcentrations
AT malerbaeleonora accuracyofaflashglucosemonitoringsystemincatsanddeterminationofthetimelagbetweenbloodglucoseandinterstitialglucoseconcentrations
AT manasseroelisa accuracyofaflashglucosemonitoringsystemincatsanddeterminationofthetimelagbetweenbloodglucoseandinterstitialglucoseconcentrations
AT gilorchen accuracyofaflashglucosemonitoringsystemincatsanddeterminationofthetimelagbetweenbloodglucoseandinterstitialglucoseconcentrations