Cargando…

Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study

BACKGROUND: With the development of modern society, severe and complex tibial fractures caused by high-energy injuries such as traffic accidents have gradually increased. At present, the commonly used methods for the treatment of tibial fractures include plate fixation, intramedullary nail fixation,...

Descripción completa

Detalles Bibliográficos
Autores principales: Sheng, Hongfeng, Xu, Weixing, Xu, Bin, Song, Hongpu, Lu, Di, Ding, Weiguo, Mildredl, Henry
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8164113/
https://www.ncbi.nlm.nih.gov/pubmed/33988516
http://dx.doi.org/10.2196/21455
_version_ 1783701047086153728
author Sheng, Hongfeng
Xu, Weixing
Xu, Bin
Song, Hongpu
Lu, Di
Ding, Weiguo
Mildredl, Henry
author_facet Sheng, Hongfeng
Xu, Weixing
Xu, Bin
Song, Hongpu
Lu, Di
Ding, Weiguo
Mildredl, Henry
author_sort Sheng, Hongfeng
collection PubMed
description BACKGROUND: With the development of modern society, severe and complex tibial fractures caused by high-energy injuries such as traffic accidents have gradually increased. At present, the commonly used methods for the treatment of tibial fractures include plate fixation, intramedullary nail fixation, and external fixation. Most of these fractures are open wounds with severe soft tissue injury and wound contamination, and some involve bone defects, which makes internal fixation treatment difficult. OBJECTIVE: This study aims to explore the use of intelligent computer-assisted Taylor 3D external fixation for the treatment of tibiofibular fractures. METHODS: In total, 70 patients were included and divided into the Taylor 3D external fixation (TSF) group (28 patients with severe tibial fractures treated with TSF) and the internal fixation group (42 patients with complicated tibiofibular fractures treated by internal fixation). After the treatment, the follow-up evaluation of TSF for the treatment of tibiofibular fractures noted the incidence of complications, as well as the efficacy and occurrence of internal fixation for the treatment of tibial fractures in our hospital. RESULTS: The results showed that TSF was superior to orthopedics in the treatment of tibiofibular fractures in terms of efficacy and complications. CONCLUSIONS: TSF for the treatment of tibiofibular fractures is more effective than internal fixation and the incidence of complications is low. This is a new technology for the treatment of tibiofibular fractures that is worthy of clinical promotion.
format Online
Article
Text
id pubmed-8164113
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-81641132021-06-03 Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study Sheng, Hongfeng Xu, Weixing Xu, Bin Song, Hongpu Lu, Di Ding, Weiguo Mildredl, Henry JMIR Med Inform Original Paper BACKGROUND: With the development of modern society, severe and complex tibial fractures caused by high-energy injuries such as traffic accidents have gradually increased. At present, the commonly used methods for the treatment of tibial fractures include plate fixation, intramedullary nail fixation, and external fixation. Most of these fractures are open wounds with severe soft tissue injury and wound contamination, and some involve bone defects, which makes internal fixation treatment difficult. OBJECTIVE: This study aims to explore the use of intelligent computer-assisted Taylor 3D external fixation for the treatment of tibiofibular fractures. METHODS: In total, 70 patients were included and divided into the Taylor 3D external fixation (TSF) group (28 patients with severe tibial fractures treated with TSF) and the internal fixation group (42 patients with complicated tibiofibular fractures treated by internal fixation). After the treatment, the follow-up evaluation of TSF for the treatment of tibiofibular fractures noted the incidence of complications, as well as the efficacy and occurrence of internal fixation for the treatment of tibial fractures in our hospital. RESULTS: The results showed that TSF was superior to orthopedics in the treatment of tibiofibular fractures in terms of efficacy and complications. CONCLUSIONS: TSF for the treatment of tibiofibular fractures is more effective than internal fixation and the incidence of complications is low. This is a new technology for the treatment of tibiofibular fractures that is worthy of clinical promotion. JMIR Publications 2021-05-14 /pmc/articles/PMC8164113/ /pubmed/33988516 http://dx.doi.org/10.2196/21455 Text en ©Hongfeng Sheng, Weixing Xu, Bin Xu, Hongpu Song, Di Lu, Weiguo Ding, Henry Mildredl. Originally published in JMIR Medical Informatics (https://medinform.jmir.org), 14.05.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Medical Informatics, is properly cited. The complete bibliographic information, a link to the original publication on http://medinform.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Sheng, Hongfeng
Xu, Weixing
Xu, Bin
Song, Hongpu
Lu, Di
Ding, Weiguo
Mildredl, Henry
Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study
title Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study
title_full Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study
title_fullStr Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study
title_full_unstemmed Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study
title_short Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study
title_sort application of intelligent computer-assisted taylor 3d external fixation in the treatment of tibiofibular fracture: retrospective case study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8164113/
https://www.ncbi.nlm.nih.gov/pubmed/33988516
http://dx.doi.org/10.2196/21455
work_keys_str_mv AT shenghongfeng applicationofintelligentcomputerassistedtaylor3dexternalfixationinthetreatmentoftibiofibularfractureretrospectivecasestudy
AT xuweixing applicationofintelligentcomputerassistedtaylor3dexternalfixationinthetreatmentoftibiofibularfractureretrospectivecasestudy
AT xubin applicationofintelligentcomputerassistedtaylor3dexternalfixationinthetreatmentoftibiofibularfractureretrospectivecasestudy
AT songhongpu applicationofintelligentcomputerassistedtaylor3dexternalfixationinthetreatmentoftibiofibularfractureretrospectivecasestudy
AT ludi applicationofintelligentcomputerassistedtaylor3dexternalfixationinthetreatmentoftibiofibularfractureretrospectivecasestudy
AT dingweiguo applicationofintelligentcomputerassistedtaylor3dexternalfixationinthetreatmentoftibiofibularfractureretrospectivecasestudy
AT mildredlhenry applicationofintelligentcomputerassistedtaylor3dexternalfixationinthetreatmentoftibiofibularfractureretrospectivecasestudy