Cargando…

Short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria

BACKGROUND: Electrocardiographic left ventricular hypertrophy (ECG‐LVH) represents preclinical cardiovascular disease and predicts cardiovascular disease morbidity and mortality. While the newly developed Peguero‐Lo Presti ECG‐LVH criteria have greater sensitivity for LVH than the Cornell voltage an...

Descripción completa

Detalles Bibliográficos
Autores principales: Drager, Dominique, Soliman, Elsayed Z., Meyer, Michelle L., Zhang, Zhu‐Ming, Alonso, Alvaro, Heiss, Gerardo, Whitsel, Eric A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8164147/
https://www.ncbi.nlm.nih.gov/pubmed/33591619
http://dx.doi.org/10.1111/anec.12829
_version_ 1783701054887559168
author Drager, Dominique
Soliman, Elsayed Z.
Meyer, Michelle L.
Zhang, Zhu‐Ming
Alonso, Alvaro
Heiss, Gerardo
Whitsel, Eric A.
author_facet Drager, Dominique
Soliman, Elsayed Z.
Meyer, Michelle L.
Zhang, Zhu‐Ming
Alonso, Alvaro
Heiss, Gerardo
Whitsel, Eric A.
author_sort Drager, Dominique
collection PubMed
description BACKGROUND: Electrocardiographic left ventricular hypertrophy (ECG‐LVH) represents preclinical cardiovascular disease and predicts cardiovascular disease morbidity and mortality. While the newly developed Peguero‐Lo Presti ECG‐LVH criteria have greater sensitivity for LVH than the Cornell voltage and Sokolow–Lyon criteria, its short‐term repeatability is unknown. Therefore, we characterized the short‐term repeatability of Peguero‐Lo Presti ECG‐LVH criteria and evaluate its agreement with Cornell voltage and Sokolow–Lyon ECG‐LVH criteria. METHODS: Participants underwent two resting, standard, 12‐lead ECGs at each of two visits one week apart (n = 63). We defined a Peguero‐Lo Presti index as a sum of the deepest S wave amplitude in any single lead and lead V(4) (i.e., S(D) + SV(4)) and defined Peguero‐Lo Presti LVH index as ≥ 2,300 µV among women and ≥ 2,800 µV among men. We estimated repeatability as an intraclass correlation coefficient (ICC), agreement as a prevalence‐adjusted bias‐adjusted kappa coefficient (κ), and precision using 95% confidence intervals (CIs). RESULTS: The Peguero‐Lo Presti index was repeatable: ICC (95% CI) = 0.94 (0.91–0.97). Within‐visit agreement of Peguero‐Lo Presti LVH was high at the first and second visits: κ (95% CI) = 0.97 (0.91–1.00) and 1.00 (1.00–1.00). Between‐visit agreement of the first and second measurements at each visit was comparable: κ (95% CI) = 0.90 (0.80–1.00) and 0.93 (0.85–1.00). Agreement of Peguero‐Lo Presti and Cornell or Sokolow–Lyon LVH on any one of the four ECGs was slightly lower: κ (95% CI) = 0.71 (0.54–0.89). CONCLUSION: The Peguero‐Lo Presti index and LVH have excellent repeatability and agreement, which support their use in clinical and epidemiological studies.
format Online
Article
Text
id pubmed-8164147
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-81641472021-06-04 Short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria Drager, Dominique Soliman, Elsayed Z. Meyer, Michelle L. Zhang, Zhu‐Ming Alonso, Alvaro Heiss, Gerardo Whitsel, Eric A. Ann Noninvasive Electrocardiol Original Articles BACKGROUND: Electrocardiographic left ventricular hypertrophy (ECG‐LVH) represents preclinical cardiovascular disease and predicts cardiovascular disease morbidity and mortality. While the newly developed Peguero‐Lo Presti ECG‐LVH criteria have greater sensitivity for LVH than the Cornell voltage and Sokolow–Lyon criteria, its short‐term repeatability is unknown. Therefore, we characterized the short‐term repeatability of Peguero‐Lo Presti ECG‐LVH criteria and evaluate its agreement with Cornell voltage and Sokolow–Lyon ECG‐LVH criteria. METHODS: Participants underwent two resting, standard, 12‐lead ECGs at each of two visits one week apart (n = 63). We defined a Peguero‐Lo Presti index as a sum of the deepest S wave amplitude in any single lead and lead V(4) (i.e., S(D) + SV(4)) and defined Peguero‐Lo Presti LVH index as ≥ 2,300 µV among women and ≥ 2,800 µV among men. We estimated repeatability as an intraclass correlation coefficient (ICC), agreement as a prevalence‐adjusted bias‐adjusted kappa coefficient (κ), and precision using 95% confidence intervals (CIs). RESULTS: The Peguero‐Lo Presti index was repeatable: ICC (95% CI) = 0.94 (0.91–0.97). Within‐visit agreement of Peguero‐Lo Presti LVH was high at the first and second visits: κ (95% CI) = 0.97 (0.91–1.00) and 1.00 (1.00–1.00). Between‐visit agreement of the first and second measurements at each visit was comparable: κ (95% CI) = 0.90 (0.80–1.00) and 0.93 (0.85–1.00). Agreement of Peguero‐Lo Presti and Cornell or Sokolow–Lyon LVH on any one of the four ECGs was slightly lower: κ (95% CI) = 0.71 (0.54–0.89). CONCLUSION: The Peguero‐Lo Presti index and LVH have excellent repeatability and agreement, which support their use in clinical and epidemiological studies. John Wiley and Sons Inc. 2021-02-16 /pmc/articles/PMC8164147/ /pubmed/33591619 http://dx.doi.org/10.1111/anec.12829 Text en © 2021 The Authors. Annals of Noninvasive Electrocardiology published by Wiley Periodicals LLC https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Drager, Dominique
Soliman, Elsayed Z.
Meyer, Michelle L.
Zhang, Zhu‐Ming
Alonso, Alvaro
Heiss, Gerardo
Whitsel, Eric A.
Short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria
title Short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria
title_full Short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria
title_fullStr Short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria
title_full_unstemmed Short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria
title_short Short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria
title_sort short‐term repeatability of the peguero‐lo presti electrocardiographic left ventricular hypertrophy criteria
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8164147/
https://www.ncbi.nlm.nih.gov/pubmed/33591619
http://dx.doi.org/10.1111/anec.12829
work_keys_str_mv AT dragerdominique shorttermrepeatabilityofthepegueroloprestielectrocardiographicleftventricularhypertrophycriteria
AT solimanelsayedz shorttermrepeatabilityofthepegueroloprestielectrocardiographicleftventricularhypertrophycriteria
AT meyermichellel shorttermrepeatabilityofthepegueroloprestielectrocardiographicleftventricularhypertrophycriteria
AT zhangzhuming shorttermrepeatabilityofthepegueroloprestielectrocardiographicleftventricularhypertrophycriteria
AT alonsoalvaro shorttermrepeatabilityofthepegueroloprestielectrocardiographicleftventricularhypertrophycriteria
AT heissgerardo shorttermrepeatabilityofthepegueroloprestielectrocardiographicleftventricularhypertrophycriteria
AT whitselerica shorttermrepeatabilityofthepegueroloprestielectrocardiographicleftventricularhypertrophycriteria