Efficacy of Hybrid Closed-Loop Insulin Delivery System in a Hospital Setting: A Case Series

OBJECTIVE: We report a case series of 4 patients with type 1 diabetes who used hybrid closed-loop insulin pumps (Medtronic MiniMed 670 G) during hospitalization. METHODS: Clinical data and point-of-care glucose values are presented for each patient. Glucose values are shown graphically while in manu...

Descripción completa

Detalles Bibliográficos
Autores principales: Atif, Zulekha, Halstrom, Amanda, Peragallo-Dittko, Virginia, Klek, Stanislaw P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Association of Clinical Endocrinology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8165117/
https://www.ncbi.nlm.nih.gov/pubmed/34095484
http://dx.doi.org/10.1016/j.aace.2020.12.013
_version_ 1783701246346002432
author Atif, Zulekha
Halstrom, Amanda
Peragallo-Dittko, Virginia
Klek, Stanislaw P.
author_facet Atif, Zulekha
Halstrom, Amanda
Peragallo-Dittko, Virginia
Klek, Stanislaw P.
author_sort Atif, Zulekha
collection PubMed
description OBJECTIVE: We report a case series of 4 patients with type 1 diabetes who used hybrid closed-loop insulin pumps (Medtronic MiniMed 670 G) during hospitalization. METHODS: Clinical data and point-of-care glucose values are presented for each patient. Glucose values are shown graphically while in manual mode as well as in auto mode. RESULTS: The first case was a 30-year-old man admitted for pancreatitis. Mean point-of-care blood glucose was 165.7 mg/dL while in auto mode, without hypoglycemia, compared with 221 mg/dL while in manual mode. The second case was a 28-year-old woman who was admitted for a laparoscopic cholecystectomy. Mean point-of-care blood glucose in auto mode was 131.3 mg/dL, without hypoglycemia, compared with 117.6 mg/dL while in manual mode. The third case was a 46-year-old man admitted to the intensive care unit for influenzal pneumonia. Mean point-of-care blood glucose in auto mode was 159.1 mg/dL without hypoglycemia, compared with 218.5 mg/dL while in manual mode. The fourth case was a 60-year-old man who remained in auto mode throughout his hospitalization except for a period when he removed his pump for an endoscopic retrograde cholangiopancreatography and endoscopic ultrasound. His mean point-of-care blood glucose while in auto mode was 156.8 mg/dL without hypoglycemia. CONCLUSION: These case reports support the use of hybrid closed-loop insulin-pump therapy in the inpatient setting to maintain inpatient glycemic targets and avoid hypoglycemia when part of an institution-sanctioned strategy for safe use of insulin pumps that includes point-of-care blood glucose monitoring.
format Online
Article
Text
id pubmed-8165117
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Association of Clinical Endocrinology
record_format MEDLINE/PubMed
spelling pubmed-81651172021-06-05 Efficacy of Hybrid Closed-Loop Insulin Delivery System in a Hospital Setting: A Case Series Atif, Zulekha Halstrom, Amanda Peragallo-Dittko, Virginia Klek, Stanislaw P. AACE Clin Case Rep Case Report OBJECTIVE: We report a case series of 4 patients with type 1 diabetes who used hybrid closed-loop insulin pumps (Medtronic MiniMed 670 G) during hospitalization. METHODS: Clinical data and point-of-care glucose values are presented for each patient. Glucose values are shown graphically while in manual mode as well as in auto mode. RESULTS: The first case was a 30-year-old man admitted for pancreatitis. Mean point-of-care blood glucose was 165.7 mg/dL while in auto mode, without hypoglycemia, compared with 221 mg/dL while in manual mode. The second case was a 28-year-old woman who was admitted for a laparoscopic cholecystectomy. Mean point-of-care blood glucose in auto mode was 131.3 mg/dL, without hypoglycemia, compared with 117.6 mg/dL while in manual mode. The third case was a 46-year-old man admitted to the intensive care unit for influenzal pneumonia. Mean point-of-care blood glucose in auto mode was 159.1 mg/dL without hypoglycemia, compared with 218.5 mg/dL while in manual mode. The fourth case was a 60-year-old man who remained in auto mode throughout his hospitalization except for a period when he removed his pump for an endoscopic retrograde cholangiopancreatography and endoscopic ultrasound. His mean point-of-care blood glucose while in auto mode was 156.8 mg/dL without hypoglycemia. CONCLUSION: These case reports support the use of hybrid closed-loop insulin-pump therapy in the inpatient setting to maintain inpatient glycemic targets and avoid hypoglycemia when part of an institution-sanctioned strategy for safe use of insulin pumps that includes point-of-care blood glucose monitoring. American Association of Clinical Endocrinology 2021-01-06 /pmc/articles/PMC8165117/ /pubmed/34095484 http://dx.doi.org/10.1016/j.aace.2020.12.013 Text en © 2021 AACE. Published by Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Atif, Zulekha
Halstrom, Amanda
Peragallo-Dittko, Virginia
Klek, Stanislaw P.
Efficacy of Hybrid Closed-Loop Insulin Delivery System in a Hospital Setting: A Case Series
title Efficacy of Hybrid Closed-Loop Insulin Delivery System in a Hospital Setting: A Case Series
title_full Efficacy of Hybrid Closed-Loop Insulin Delivery System in a Hospital Setting: A Case Series
title_fullStr Efficacy of Hybrid Closed-Loop Insulin Delivery System in a Hospital Setting: A Case Series
title_full_unstemmed Efficacy of Hybrid Closed-Loop Insulin Delivery System in a Hospital Setting: A Case Series
title_short Efficacy of Hybrid Closed-Loop Insulin Delivery System in a Hospital Setting: A Case Series
title_sort efficacy of hybrid closed-loop insulin delivery system in a hospital setting: a case series
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8165117/
https://www.ncbi.nlm.nih.gov/pubmed/34095484
http://dx.doi.org/10.1016/j.aace.2020.12.013
work_keys_str_mv AT atifzulekha efficacyofhybridclosedloopinsulindeliverysysteminahospitalsettingacaseseries
AT halstromamanda efficacyofhybridclosedloopinsulindeliverysysteminahospitalsettingacaseseries
AT peragallodittkovirginia efficacyofhybridclosedloopinsulindeliverysysteminahospitalsettingacaseseries
AT klekstanislawp efficacyofhybridclosedloopinsulindeliverysysteminahospitalsettingacaseseries