Cargando…
Establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model
BACKGROUND: Tunnel position deicide the isometry of graft attachment in synthetic anterior cruciate ligament (ACL) reconstruction. Near-isometric tunnel position may have advantage in graft integration and knee function in ACL reconstruction (ACLR) with polyethylene terephthalate (PET) ligament. Few...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Chinese Speaking Orthopaedic Society
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8165294/ https://www.ncbi.nlm.nih.gov/pubmed/34136347 http://dx.doi.org/10.1016/j.jot.2021.04.008 |
_version_ | 1783701288773484544 |
---|---|
author | Jin, Wenhe Cai, Jiangyu Sheng, Dandan Liu, Xingwang Chen, Jun Chen, Shiyi |
author_facet | Jin, Wenhe Cai, Jiangyu Sheng, Dandan Liu, Xingwang Chen, Jun Chen, Shiyi |
author_sort | Jin, Wenhe |
collection | PubMed |
description | BACKGROUND: Tunnel position deicide the isometry of graft attachment in synthetic anterior cruciate ligament (ACL) reconstruction. Near-isometric tunnel position may have advantage in graft integration and knee function in ACL reconstruction (ACLR) with polyethylene terephthalate (PET) ligament. Few studies focused on tunnel position isometry when conduct ACLR with an animal model. This study aimed to establish a preclinical rabbit model of near and non isometric ACLR with PET ligament and investigate the advantage of near-isometric ACLR compared to non-isometric ACLR. METHODS: Nine hind limbs of rabbit were used in tunnel position study. Two femoral(anatomic, nonanatomic) tunnels and three tibial(anterior, middle, posterior) tunnels were used to measure tunnel position isometry during knee full range of motion. The tunnel position combination with minimal isometry was considered as near-isometric tunnel position. Then, 48 rabbits divided into two groups were conducted near or non isometric ACLR with PET ligament with graft fixation angle of 30° and constant tension of 5N. PET ligament isometry, range of motion(ROM) restriction, knee laxity were recorded after operation and followed up with macroscopic observation, microcomputed tomography (micro-CT) analysis, histology assessment and biomechanical test at 4 and 8 weeks postoperatively. RESULTS: The tunnel combination with minimal isometry was femoral anatomic position and tibial posterior position(5.19 ± 1.78%) and considered as near-isometric tunnel position. ROM restriction were observed in non-isometric group (22.50 ± 14.14°) while none in near-isometric group. However, no ROM restriction observed at 8 weeks in both group. Knee laxity compared to contralateral knee were better in near-isometric group than non-isometric group (stable/slack/total 10/2/12 VS 3/9/12, p = 0.012) at 8 weeks postoperatively. Supeiror PET ligament integration were also observed in near-isometric group through macroscopic observation, micro-CT analysis, histology assessment at both 4 and 8 weeks. The failure load in the Near-Isometric group at 8 weeks were higher than timezero reconstruction with statistical difference (156.8N ± 25.98N vs.102.6 ± 22.96N, p = 0.02). CONCLUSION: A rabbit model of ACLR based on tunnel position isometry was successfully established in this study. The near-isometric tunnel position in rabbit model was femoral anatomic position and tibial posterior position. A near-isometric ACLR with PET ligament did not cause ROM restriction and had a better graft integration and follow-up stability than non-isometric ACLR with ROM restriction. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The study demonstrate the establishmentof near-isometric tunnel position and non-isometric tunnel position with significant difference of ROM restriction and graft-bone integration. The described tunnel positions with differential isometry in a rabbit ACLR provides a reproducible and translational small animal model and enables preclinical research between tunnel position isometry and its affection on variable grafts, graft integration and knee function. |
format | Online Article Text |
id | pubmed-8165294 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Chinese Speaking Orthopaedic Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-81652942021-06-15 Establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model Jin, Wenhe Cai, Jiangyu Sheng, Dandan Liu, Xingwang Chen, Jun Chen, Shiyi J Orthop Translat Original Article BACKGROUND: Tunnel position deicide the isometry of graft attachment in synthetic anterior cruciate ligament (ACL) reconstruction. Near-isometric tunnel position may have advantage in graft integration and knee function in ACL reconstruction (ACLR) with polyethylene terephthalate (PET) ligament. Few studies focused on tunnel position isometry when conduct ACLR with an animal model. This study aimed to establish a preclinical rabbit model of near and non isometric ACLR with PET ligament and investigate the advantage of near-isometric ACLR compared to non-isometric ACLR. METHODS: Nine hind limbs of rabbit were used in tunnel position study. Two femoral(anatomic, nonanatomic) tunnels and three tibial(anterior, middle, posterior) tunnels were used to measure tunnel position isometry during knee full range of motion. The tunnel position combination with minimal isometry was considered as near-isometric tunnel position. Then, 48 rabbits divided into two groups were conducted near or non isometric ACLR with PET ligament with graft fixation angle of 30° and constant tension of 5N. PET ligament isometry, range of motion(ROM) restriction, knee laxity were recorded after operation and followed up with macroscopic observation, microcomputed tomography (micro-CT) analysis, histology assessment and biomechanical test at 4 and 8 weeks postoperatively. RESULTS: The tunnel combination with minimal isometry was femoral anatomic position and tibial posterior position(5.19 ± 1.78%) and considered as near-isometric tunnel position. ROM restriction were observed in non-isometric group (22.50 ± 14.14°) while none in near-isometric group. However, no ROM restriction observed at 8 weeks in both group. Knee laxity compared to contralateral knee were better in near-isometric group than non-isometric group (stable/slack/total 10/2/12 VS 3/9/12, p = 0.012) at 8 weeks postoperatively. Supeiror PET ligament integration were also observed in near-isometric group through macroscopic observation, micro-CT analysis, histology assessment at both 4 and 8 weeks. The failure load in the Near-Isometric group at 8 weeks were higher than timezero reconstruction with statistical difference (156.8N ± 25.98N vs.102.6 ± 22.96N, p = 0.02). CONCLUSION: A rabbit model of ACLR based on tunnel position isometry was successfully established in this study. The near-isometric tunnel position in rabbit model was femoral anatomic position and tibial posterior position. A near-isometric ACLR with PET ligament did not cause ROM restriction and had a better graft integration and follow-up stability than non-isometric ACLR with ROM restriction. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The study demonstrate the establishmentof near-isometric tunnel position and non-isometric tunnel position with significant difference of ROM restriction and graft-bone integration. The described tunnel positions with differential isometry in a rabbit ACLR provides a reproducible and translational small animal model and enables preclinical research between tunnel position isometry and its affection on variable grafts, graft integration and knee function. Chinese Speaking Orthopaedic Society 2021-05-21 /pmc/articles/PMC8165294/ /pubmed/34136347 http://dx.doi.org/10.1016/j.jot.2021.04.008 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Jin, Wenhe Cai, Jiangyu Sheng, Dandan Liu, Xingwang Chen, Jun Chen, Shiyi Establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model |
title | Establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model |
title_full | Establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model |
title_fullStr | Establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model |
title_full_unstemmed | Establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model |
title_short | Establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model |
title_sort | establishment of near and non isometric anterior cruciate ligament reconstruction with artificial ligament in a rabbit model |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8165294/ https://www.ncbi.nlm.nih.gov/pubmed/34136347 http://dx.doi.org/10.1016/j.jot.2021.04.008 |
work_keys_str_mv | AT jinwenhe establishmentofnearandnonisometricanteriorcruciateligamentreconstructionwithartificialligamentinarabbitmodel AT caijiangyu establishmentofnearandnonisometricanteriorcruciateligamentreconstructionwithartificialligamentinarabbitmodel AT shengdandan establishmentofnearandnonisometricanteriorcruciateligamentreconstructionwithartificialligamentinarabbitmodel AT liuxingwang establishmentofnearandnonisometricanteriorcruciateligamentreconstructionwithartificialligamentinarabbitmodel AT chenjun establishmentofnearandnonisometricanteriorcruciateligamentreconstructionwithartificialligamentinarabbitmodel AT chenshiyi establishmentofnearandnonisometricanteriorcruciateligamentreconstructionwithartificialligamentinarabbitmodel |