Cargando…

Saphenous Nerve Somatosensory-Evoked Potentials Monitoring During Lateral Interbody Fusion

STUDY DESIGN.: Retrospective cohort study. OBJECTIVES: To clinically evaluate saphenous nerve somatosensory-evoked potentials (SSEPs) as a reliable and predictable way to detect upper lumbar plexus injury intraoperatively during lateral lumbar trans-psoas interbody fusion (LLIF). METHODS: Saphenous...

Descripción completa

Detalles Bibliográficos
Autores principales: Jain, Nick, Alluri, Ram, Phan, Kevin, Yanni, Daniel, Alvarez, Andrew, Guillen, Herbierto, Mnatsakanyan, Lilit, Bederman, S. Samuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8165933/
https://www.ncbi.nlm.nih.gov/pubmed/32875905
http://dx.doi.org/10.1177/2192568220922979
_version_ 1783701413260427264
author Jain, Nick
Alluri, Ram
Phan, Kevin
Yanni, Daniel
Alvarez, Andrew
Guillen, Herbierto
Mnatsakanyan, Lilit
Bederman, S. Samuel
author_facet Jain, Nick
Alluri, Ram
Phan, Kevin
Yanni, Daniel
Alvarez, Andrew
Guillen, Herbierto
Mnatsakanyan, Lilit
Bederman, S. Samuel
author_sort Jain, Nick
collection PubMed
description STUDY DESIGN.: Retrospective cohort study. OBJECTIVES: To clinically evaluate saphenous nerve somatosensory-evoked potentials (SSEPs) as a reliable and predictable way to detect upper lumbar plexus injury intraoperatively during lateral lumbar trans-psoas interbody fusion (LLIF). METHODS: Saphenous nerve SSEPs were obtained by stimulation of inferior medial thigh with needle electrodes and recording from transcranial potentials. The primary outcome was measured by testing reproducibility of SSEPs at baseline, changes during the procedure, and relevance to standard modalities. Significant SSEP changes were compared with actual postoperative nerve complications. The sensitivity and specificity of saphenous SSEPs to detect postoperative lumbar plexus nerve injury was calculated. RESULTS: A total of 62 patients were included in the study. Reliable saphenous SSEPs were recorded on the LLIF approach side in 52/62 patients. Persistent saphenous SSEP reduction of amplitude of >50% in 6 cases was observed during expansion of the tubular retractor or during the procedure. Two of 6 patients postoperatively had femoral nerve sensory deficits, and 5 of 6 patients had mild femoral nerve motor weakness, all of which resolved at an average of 12 weeks postoperatively (range 2-24 weeks). One patient had saphenous SSEP changes but demonstrated intraoperative recovery and had no postoperative clinical deficits. Saphenous SSEPs demonstrated 52% to 100% sensitivity and 90% to 100% specificity for detecting postoperative femoral nerve complications. CONCLUSION: Saphenous SSEPs can be used to detect electrophysiological changes to prevent femoral nerve injury during LLIF. Intraoperative SSEP recovery after amplitude reduction or loss may be a prognostic factor for final clinical outcome.
format Online
Article
Text
id pubmed-8165933
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-81659332021-06-07 Saphenous Nerve Somatosensory-Evoked Potentials Monitoring During Lateral Interbody Fusion Jain, Nick Alluri, Ram Phan, Kevin Yanni, Daniel Alvarez, Andrew Guillen, Herbierto Mnatsakanyan, Lilit Bederman, S. Samuel Global Spine J Original Articles STUDY DESIGN.: Retrospective cohort study. OBJECTIVES: To clinically evaluate saphenous nerve somatosensory-evoked potentials (SSEPs) as a reliable and predictable way to detect upper lumbar plexus injury intraoperatively during lateral lumbar trans-psoas interbody fusion (LLIF). METHODS: Saphenous nerve SSEPs were obtained by stimulation of inferior medial thigh with needle electrodes and recording from transcranial potentials. The primary outcome was measured by testing reproducibility of SSEPs at baseline, changes during the procedure, and relevance to standard modalities. Significant SSEP changes were compared with actual postoperative nerve complications. The sensitivity and specificity of saphenous SSEPs to detect postoperative lumbar plexus nerve injury was calculated. RESULTS: A total of 62 patients were included in the study. Reliable saphenous SSEPs were recorded on the LLIF approach side in 52/62 patients. Persistent saphenous SSEP reduction of amplitude of >50% in 6 cases was observed during expansion of the tubular retractor or during the procedure. Two of 6 patients postoperatively had femoral nerve sensory deficits, and 5 of 6 patients had mild femoral nerve motor weakness, all of which resolved at an average of 12 weeks postoperatively (range 2-24 weeks). One patient had saphenous SSEP changes but demonstrated intraoperative recovery and had no postoperative clinical deficits. Saphenous SSEPs demonstrated 52% to 100% sensitivity and 90% to 100% specificity for detecting postoperative femoral nerve complications. CONCLUSION: Saphenous SSEPs can be used to detect electrophysiological changes to prevent femoral nerve injury during LLIF. Intraoperative SSEP recovery after amplitude reduction or loss may be a prognostic factor for final clinical outcome. SAGE Publications 2020-05-15 2021-06 /pmc/articles/PMC8165933/ /pubmed/32875905 http://dx.doi.org/10.1177/2192568220922979 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Jain, Nick
Alluri, Ram
Phan, Kevin
Yanni, Daniel
Alvarez, Andrew
Guillen, Herbierto
Mnatsakanyan, Lilit
Bederman, S. Samuel
Saphenous Nerve Somatosensory-Evoked Potentials Monitoring During Lateral Interbody Fusion
title Saphenous Nerve Somatosensory-Evoked Potentials Monitoring During Lateral Interbody Fusion
title_full Saphenous Nerve Somatosensory-Evoked Potentials Monitoring During Lateral Interbody Fusion
title_fullStr Saphenous Nerve Somatosensory-Evoked Potentials Monitoring During Lateral Interbody Fusion
title_full_unstemmed Saphenous Nerve Somatosensory-Evoked Potentials Monitoring During Lateral Interbody Fusion
title_short Saphenous Nerve Somatosensory-Evoked Potentials Monitoring During Lateral Interbody Fusion
title_sort saphenous nerve somatosensory-evoked potentials monitoring during lateral interbody fusion
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8165933/
https://www.ncbi.nlm.nih.gov/pubmed/32875905
http://dx.doi.org/10.1177/2192568220922979
work_keys_str_mv AT jainnick saphenousnervesomatosensoryevokedpotentialsmonitoringduringlateralinterbodyfusion
AT alluriram saphenousnervesomatosensoryevokedpotentialsmonitoringduringlateralinterbodyfusion
AT phankevin saphenousnervesomatosensoryevokedpotentialsmonitoringduringlateralinterbodyfusion
AT yannidaniel saphenousnervesomatosensoryevokedpotentialsmonitoringduringlateralinterbodyfusion
AT alvarezandrew saphenousnervesomatosensoryevokedpotentialsmonitoringduringlateralinterbodyfusion
AT guillenherbierto saphenousnervesomatosensoryevokedpotentialsmonitoringduringlateralinterbodyfusion
AT mnatsakanyanlilit saphenousnervesomatosensoryevokedpotentialsmonitoringduringlateralinterbodyfusion
AT bedermanssamuel saphenousnervesomatosensoryevokedpotentialsmonitoringduringlateralinterbodyfusion