Cargando…
Truncated correlation photoacoustic coherence tomography: An axial resolution enhancement imaging modality
In this report we present a novel photoacoustic (PA) modality using pulsed chirp excitation at a fixed wavelength and spectral analysis based on frequency-domain (FD) processing. We introduce Truncated Correlation Photoacoustic Coherence Tomography (TC-PACT), a PA axial resolution enhancement method...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8167188/ https://www.ncbi.nlm.nih.gov/pubmed/34094853 http://dx.doi.org/10.1016/j.pacs.2021.100277 |
_version_ | 1783701642174005248 |
---|---|
author | Jangjoo, Alireza Lashkari, Bahman Sivagurunathan, Koneswaran Mandelis, Andreas Baezzat, Mohammad Reza |
author_facet | Jangjoo, Alireza Lashkari, Bahman Sivagurunathan, Koneswaran Mandelis, Andreas Baezzat, Mohammad Reza |
author_sort | Jangjoo, Alireza |
collection | PubMed |
description | In this report we present a novel photoacoustic (PA) modality using pulsed chirp excitation at a fixed wavelength and spectral analysis based on frequency-domain (FD) processing. We introduce Truncated Correlation Photoacoustic Coherence Tomography (TC-PACT), a PA axial resolution enhancement methodology, with an application to closely stacked subsurface multilayers of plexiglass coated with a thin layer of graphite acting as surface absorber. The experimental results demonstrated that the SNR and the axial resolution were higher in TC-PACT than in conventional FD photoacoustics. A ns pulsed laser was also used as PA excitation source with axial resolution results found to be commensurate with TC-PACT. However, the separation distance between adjacent absorbers when the latter approached the axial resolution limit of the transducer was only resolved in TC-PACT compared to pulsed laser PA owing to the lower uncertainty in the former modality involved in determining the location of the absorbers. |
format | Online Article Text |
id | pubmed-8167188 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-81671882021-06-05 Truncated correlation photoacoustic coherence tomography: An axial resolution enhancement imaging modality Jangjoo, Alireza Lashkari, Bahman Sivagurunathan, Koneswaran Mandelis, Andreas Baezzat, Mohammad Reza Photoacoustics Research Article In this report we present a novel photoacoustic (PA) modality using pulsed chirp excitation at a fixed wavelength and spectral analysis based on frequency-domain (FD) processing. We introduce Truncated Correlation Photoacoustic Coherence Tomography (TC-PACT), a PA axial resolution enhancement methodology, with an application to closely stacked subsurface multilayers of plexiglass coated with a thin layer of graphite acting as surface absorber. The experimental results demonstrated that the SNR and the axial resolution were higher in TC-PACT than in conventional FD photoacoustics. A ns pulsed laser was also used as PA excitation source with axial resolution results found to be commensurate with TC-PACT. However, the separation distance between adjacent absorbers when the latter approached the axial resolution limit of the transducer was only resolved in TC-PACT compared to pulsed laser PA owing to the lower uncertainty in the former modality involved in determining the location of the absorbers. Elsevier 2021-05-21 /pmc/articles/PMC8167188/ /pubmed/34094853 http://dx.doi.org/10.1016/j.pacs.2021.100277 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Jangjoo, Alireza Lashkari, Bahman Sivagurunathan, Koneswaran Mandelis, Andreas Baezzat, Mohammad Reza Truncated correlation photoacoustic coherence tomography: An axial resolution enhancement imaging modality |
title | Truncated correlation photoacoustic coherence tomography: An axial resolution enhancement imaging modality |
title_full | Truncated correlation photoacoustic coherence tomography: An axial resolution enhancement imaging modality |
title_fullStr | Truncated correlation photoacoustic coherence tomography: An axial resolution enhancement imaging modality |
title_full_unstemmed | Truncated correlation photoacoustic coherence tomography: An axial resolution enhancement imaging modality |
title_short | Truncated correlation photoacoustic coherence tomography: An axial resolution enhancement imaging modality |
title_sort | truncated correlation photoacoustic coherence tomography: an axial resolution enhancement imaging modality |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8167188/ https://www.ncbi.nlm.nih.gov/pubmed/34094853 http://dx.doi.org/10.1016/j.pacs.2021.100277 |
work_keys_str_mv | AT jangjooalireza truncatedcorrelationphotoacousticcoherencetomographyanaxialresolutionenhancementimagingmodality AT lashkaribahman truncatedcorrelationphotoacousticcoherencetomographyanaxialresolutionenhancementimagingmodality AT sivagurunathankoneswaran truncatedcorrelationphotoacousticcoherencetomographyanaxialresolutionenhancementimagingmodality AT mandelisandreas truncatedcorrelationphotoacousticcoherencetomographyanaxialresolutionenhancementimagingmodality AT baezzatmohammadreza truncatedcorrelationphotoacousticcoherencetomographyanaxialresolutionenhancementimagingmodality |