Cargando…
Failed carotid artery stenting followed by successful surgical intervention: Case report
A 56-year-old female patient with significant carotid stenoses with circumferential plaques, causing localized vascular narrowing, was inappropriately indicated for carotid artery stenting. After placement of a distal embolic protection device in the left internal carotid artery, a stent was inserte...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bayçınar Medical Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8167460/ https://www.ncbi.nlm.nih.gov/pubmed/34104521 http://dx.doi.org/10.5606/tgkdc.dergisi.2021.21207 |
_version_ | 1783701695734218752 |
---|---|
author | Govedarski, Valentin Dimitrova, Elitsa Vassileva, Zornitsa Dimitrov, Svetoslav Iovev, Svetoslav |
author_facet | Govedarski, Valentin Dimitrova, Elitsa Vassileva, Zornitsa Dimitrov, Svetoslav Iovev, Svetoslav |
author_sort | Govedarski, Valentin |
collection | PubMed |
description | A 56-year-old female patient with significant carotid stenoses with circumferential plaques, causing localized vascular narrowing, was inappropriately indicated for carotid artery stenting. After placement of a distal embolic protection device in the left internal carotid artery, a stent was inserted; however, it could not be fully deployed due to the rigid, severely calcified vascular walls. The various endovascular attempts to recapture the protection device were futile and, eventually, led to fracture of the guidewire of the device and it remained entrapped together with the stent. Emergency carotid arteriotomy with extirpation of the stent and embolic protection device via carotid thromboendarterectomy was performed. In conclusion, the proper patient selection for carotid artery stenting is of utmost importance. |
format | Online Article Text |
id | pubmed-8167460 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Bayçınar Medical Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-81674602021-06-07 Failed carotid artery stenting followed by successful surgical intervention: Case report Govedarski, Valentin Dimitrova, Elitsa Vassileva, Zornitsa Dimitrov, Svetoslav Iovev, Svetoslav Turk Gogus Kalp Damar Cerrahisi Derg Case Report A 56-year-old female patient with significant carotid stenoses with circumferential plaques, causing localized vascular narrowing, was inappropriately indicated for carotid artery stenting. After placement of a distal embolic protection device in the left internal carotid artery, a stent was inserted; however, it could not be fully deployed due to the rigid, severely calcified vascular walls. The various endovascular attempts to recapture the protection device were futile and, eventually, led to fracture of the guidewire of the device and it remained entrapped together with the stent. Emergency carotid arteriotomy with extirpation of the stent and embolic protection device via carotid thromboendarterectomy was performed. In conclusion, the proper patient selection for carotid artery stenting is of utmost importance. Bayçınar Medical Publishing 2021-04-26 /pmc/articles/PMC8167460/ /pubmed/34104521 http://dx.doi.org/10.5606/tgkdc.dergisi.2021.21207 Text en Copyright © 2021, Turkish Society of Cardiovascular Surgery https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Case Report Govedarski, Valentin Dimitrova, Elitsa Vassileva, Zornitsa Dimitrov, Svetoslav Iovev, Svetoslav Failed carotid artery stenting followed by successful surgical intervention: Case report |
title | Failed carotid artery stenting followed by successful surgical intervention: Case report |
title_full | Failed carotid artery stenting followed by successful surgical intervention: Case report |
title_fullStr | Failed carotid artery stenting followed by successful surgical intervention: Case report |
title_full_unstemmed | Failed carotid artery stenting followed by successful surgical intervention: Case report |
title_short | Failed carotid artery stenting followed by successful surgical intervention: Case report |
title_sort | failed carotid artery stenting followed by successful surgical intervention: case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8167460/ https://www.ncbi.nlm.nih.gov/pubmed/34104521 http://dx.doi.org/10.5606/tgkdc.dergisi.2021.21207 |
work_keys_str_mv | AT govedarskivalentin failedcarotidarterystentingfollowedbysuccessfulsurgicalinterventioncasereport AT dimitrovaelitsa failedcarotidarterystentingfollowedbysuccessfulsurgicalinterventioncasereport AT vassilevazornitsa failedcarotidarterystentingfollowedbysuccessfulsurgicalinterventioncasereport AT dimitrovsvetoslav failedcarotidarterystentingfollowedbysuccessfulsurgicalinterventioncasereport AT iovevsvetoslav failedcarotidarterystentingfollowedbysuccessfulsurgicalinterventioncasereport |