Cargando…

Multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics

We report non-invasive, bilateral optical measurements on the forehead of five healthy human subjects, of 0.1 Hz oscillatory hemodynamics elicited either by cyclic inflation of pneumatic thigh cuffs, or by paced breathing. Optical intensity and the phase of photon-density waves were collected with f...

Descripción completa

Detalles Bibliográficos
Autores principales: Blaney, Giles, Sassaroli, Angelo, Pham, Thao, Krishnamurthy, Nishanth, Fantini, Sergio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8168742/
https://www.ncbi.nlm.nih.gov/pubmed/34079837
http://dx.doi.org/10.3390/photonics6030083
_version_ 1783701924820811776
author Blaney, Giles
Sassaroli, Angelo
Pham, Thao
Krishnamurthy, Nishanth
Fantini, Sergio
author_facet Blaney, Giles
Sassaroli, Angelo
Pham, Thao
Krishnamurthy, Nishanth
Fantini, Sergio
author_sort Blaney, Giles
collection PubMed
description We report non-invasive, bilateral optical measurements on the forehead of five healthy human subjects, of 0.1 Hz oscillatory hemodynamics elicited either by cyclic inflation of pneumatic thigh cuffs, or by paced breathing. Optical intensity and the phase of photon-density waves were collected with frequency-domain near-infrared spectroscopy at seven source-detector distances (11-40 mm). Coherent hemodynamic oscillations are represented by phasors of oxyhemoglobin (O) and deoxyhemoglobin (D) concentrations, and by the vector D/O that represents the amplitude ratio and phase difference of D and O. We found that, on average, the amplitude ratio (|D/O|) and the phase difference (∠(D/O)) obtained with single-distance intensity at 11-40 mm increase from 0.1 and −330°, to 0.2 and −200°, respectively. Single-distance phase and the intensity slope featured a weaker dependence on source-detector separation, and yielded |D/O| and ∠(D/O) values of about 0.5 and −200°, respectively, at distances greater than 20 mm. The key findings are: (1) single-distance phase and intensity slope are sensitive to deeper tissue compared to single-distance intensity; (2) deeper tissue hemodynamic oscillations, which more closely represent the brain, feature D and O phasors that are consistent with a greater relative flow-to-volume contributions in brain tissue compared to extracerebral, superficial tissue.
format Online
Article
Text
id pubmed-8168742
institution National Center for Biotechnology Information
language English
publishDate 2019
record_format MEDLINE/PubMed
spelling pubmed-81687422021-06-01 Multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics Blaney, Giles Sassaroli, Angelo Pham, Thao Krishnamurthy, Nishanth Fantini, Sergio Photonics Article We report non-invasive, bilateral optical measurements on the forehead of five healthy human subjects, of 0.1 Hz oscillatory hemodynamics elicited either by cyclic inflation of pneumatic thigh cuffs, or by paced breathing. Optical intensity and the phase of photon-density waves were collected with frequency-domain near-infrared spectroscopy at seven source-detector distances (11-40 mm). Coherent hemodynamic oscillations are represented by phasors of oxyhemoglobin (O) and deoxyhemoglobin (D) concentrations, and by the vector D/O that represents the amplitude ratio and phase difference of D and O. We found that, on average, the amplitude ratio (|D/O|) and the phase difference (∠(D/O)) obtained with single-distance intensity at 11-40 mm increase from 0.1 and −330°, to 0.2 and −200°, respectively. Single-distance phase and the intensity slope featured a weaker dependence on source-detector separation, and yielded |D/O| and ∠(D/O) values of about 0.5 and −200°, respectively, at distances greater than 20 mm. The key findings are: (1) single-distance phase and intensity slope are sensitive to deeper tissue compared to single-distance intensity; (2) deeper tissue hemodynamic oscillations, which more closely represent the brain, feature D and O phasors that are consistent with a greater relative flow-to-volume contributions in brain tissue compared to extracerebral, superficial tissue. 2019-07-26 2019 /pmc/articles/PMC8168742/ /pubmed/34079837 http://dx.doi.org/10.3390/photonics6030083 Text en https://creativecommons.org/licenses/by/4.0/Submitted for possible open access publication under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) )
spellingShingle Article
Blaney, Giles
Sassaroli, Angelo
Pham, Thao
Krishnamurthy, Nishanth
Fantini, Sergio
Multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics
title Multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics
title_full Multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics
title_fullStr Multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics
title_full_unstemmed Multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics
title_short Multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics
title_sort multi-distance frequency-domain optical measurements of coherent cerebral hemodynamics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8168742/
https://www.ncbi.nlm.nih.gov/pubmed/34079837
http://dx.doi.org/10.3390/photonics6030083
work_keys_str_mv AT blaneygiles multidistancefrequencydomainopticalmeasurementsofcoherentcerebralhemodynamics
AT sassaroliangelo multidistancefrequencydomainopticalmeasurementsofcoherentcerebralhemodynamics
AT phamthao multidistancefrequencydomainopticalmeasurementsofcoherentcerebralhemodynamics
AT krishnamurthynishanth multidistancefrequencydomainopticalmeasurementsofcoherentcerebralhemodynamics
AT fantinisergio multidistancefrequencydomainopticalmeasurementsofcoherentcerebralhemodynamics