Successful removal of a Life-threatening PE using the INARI flow triever device.
The authors report a case of a 75-year-old male with pulmonary embolism (PE) successfully treated using the INARI FlowTriever System, a mechanical thrombectomy device. Imaging confirmed deep vein thrombosis and PE presented after two days of left lower extremity (LLE) pain and dyspnea on exertion wi...