Cargando…
Consolidated lung on contrast-enhanced chest CT: the use of spectral-detector computed tomography parameters in differentiating atelectasis and pneumonia
OBJECTIVES: To investigate the value of spectral-detector computed tomography (SDCT) parameters for the quantitative differentiation between atelectasis and pneumonia on contrast-enhanced chest CT. MATERIAL AND METHODS: Sixty-three patients, 22 clinically diagnosed with pneumonia and 41 with atelect...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170158/ https://www.ncbi.nlm.nih.gov/pubmed/34113729 http://dx.doi.org/10.1016/j.heliyon.2021.e07066 |
Sumario: | OBJECTIVES: To investigate the value of spectral-detector computed tomography (SDCT) parameters for the quantitative differentiation between atelectasis and pneumonia on contrast-enhanced chest CT. MATERIAL AND METHODS: Sixty-three patients, 22 clinically diagnosed with pneumonia and 41 with atelectasis, underwent contrast-enhanced SDCT scans during the venous phase. CT numbers (Hounsfield Units [HU]) were measured on conventional reconstructions (CON(120kVp)) and the iodine concentration (C(iodine), [mg/ml]), and effective atomic number (Z(eff)) on spectral reconstructions, using region-of-interest (ROI) analysis. Receiver operating characteristics (ROC) and contrast-to-noise ratios (CNRs) were calculated to assess each reconstruction's potential to differentiate between atelectasis and pneumonia. RESULTS: On contrast-enhanced SDCT, the difference between atelectasis and pneumonia was significant on CON(120kVp), C(iodine), and Z(eff) images (p < 0.001). On CON(120kVp) images, a threshold of 81 HU achieved a sensitivity of 93 % and a specificity of 95 % for identifying pneumonia, while C(iodine) and Z(eff) images reached the same sensitivity but lower specificities of 85 % and 83 %. CON(120kVp) images showed significantly higher CNRs between normal lung and atelectasis or pneumonia with 30.63 and 27.69 compared to C(iodine) images with 3.54 and 1.27 and Z(eff) images with 4.22 and 7.63 (p < 0.001). None of the parameters could differentiate atelectasis and pneumonia without contrast media. CONCLUSIONS: Contrast-enhanced SDCT can differentiate atelectasis and pneumonia based on the spectral parameters C(iodine), and Z(eff.) However, they had no added value compared to CT number measurement on CON(120kVp) images. Furthermore, contrast media is still needed for a differentiation based on quantitative SDCT parameters. |
---|