Cargando…
Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems
OBJECTIVES: This study was conducted to compare the microleakage and characteristics of the resin-tooth tissue interface between self-etch and etch-and-rinse adhesive systems after 48 hours and 3 months. MATERIALS AND METHODS: 40 extracted premolar teeth were randomly divided into 2 groups: 1-step s...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Conservative Dentistry
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170381/ https://www.ncbi.nlm.nih.gov/pubmed/34123766 http://dx.doi.org/10.5395/rde.2021.46.e30 |
_version_ | 1783702230936846336 |
---|---|
author | Tran, Xuan Vinh Tran, Khanh Quang |
author_facet | Tran, Xuan Vinh Tran, Khanh Quang |
author_sort | Tran, Xuan Vinh |
collection | PubMed |
description | OBJECTIVES: This study was conducted to compare the microleakage and characteristics of the resin-tooth tissue interface between self-etch and etch-and-rinse adhesive systems after 48 hours and 3 months. MATERIALS AND METHODS: 40 extracted premolar teeth were randomly divided into 2 groups: 1-step self-etch adhesive system – Optibond™ All-In-One, and 2-step etch-and-rinse adhesive system - Adper™ Single Bond 2. Both groups were subjected to 500 thermocycles (5°C–55°C) before scanning electron microscope (SEM) analysis or microleakage trial at 48-hour and 3-month time periods. RESULTS: SEM images showed the hybrid layer thickness, diameter, and length of resin tags of the self-etch adhesive (0.42 ± 0.14 µm; 1.49 ± 0.45 µm; 16.35 ± 14.26 µm) were smaller than those of the etch-and-rinse adhesive (4.39 ± 1.52 µm; 3.49 ± 1 µm; 52.81 ± 35.81 µm). In dentin, the microleakage scores of the 2 adhesives were not different in both time periods (48 hours/3 months). However, the microleakage score of etch-and-rinse adhesive increased significantly after 3 months (0.8 ± 0.63 and 1.9 ± 0.88, p < 0.05). CONCLUSIONS: The self-etch adhesive exhibited better long-term sealing ability in dentin when compared to that of the etch-and-rinse adhesive. The greater hybrid layer thickness and dimensions of resin tags did not guarantee reliable, long-lasting sealing in the bonding area. |
format | Online Article Text |
id | pubmed-8170381 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Korean Academy of Conservative Dentistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-81703812021-06-11 Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems Tran, Xuan Vinh Tran, Khanh Quang Restor Dent Endod Research Article OBJECTIVES: This study was conducted to compare the microleakage and characteristics of the resin-tooth tissue interface between self-etch and etch-and-rinse adhesive systems after 48 hours and 3 months. MATERIALS AND METHODS: 40 extracted premolar teeth were randomly divided into 2 groups: 1-step self-etch adhesive system – Optibond™ All-In-One, and 2-step etch-and-rinse adhesive system - Adper™ Single Bond 2. Both groups were subjected to 500 thermocycles (5°C–55°C) before scanning electron microscope (SEM) analysis or microleakage trial at 48-hour and 3-month time periods. RESULTS: SEM images showed the hybrid layer thickness, diameter, and length of resin tags of the self-etch adhesive (0.42 ± 0.14 µm; 1.49 ± 0.45 µm; 16.35 ± 14.26 µm) were smaller than those of the etch-and-rinse adhesive (4.39 ± 1.52 µm; 3.49 ± 1 µm; 52.81 ± 35.81 µm). In dentin, the microleakage scores of the 2 adhesives were not different in both time periods (48 hours/3 months). However, the microleakage score of etch-and-rinse adhesive increased significantly after 3 months (0.8 ± 0.63 and 1.9 ± 0.88, p < 0.05). CONCLUSIONS: The self-etch adhesive exhibited better long-term sealing ability in dentin when compared to that of the etch-and-rinse adhesive. The greater hybrid layer thickness and dimensions of resin tags did not guarantee reliable, long-lasting sealing in the bonding area. The Korean Academy of Conservative Dentistry 2021-05-18 /pmc/articles/PMC8170381/ /pubmed/34123766 http://dx.doi.org/10.5395/rde.2021.46.e30 Text en Copyright © 2021. The Korean Academy of Conservative Dentistry https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Tran, Xuan Vinh Tran, Khanh Quang Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems |
title | Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems |
title_full | Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems |
title_fullStr | Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems |
title_full_unstemmed | Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems |
title_short | Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems |
title_sort | microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170381/ https://www.ncbi.nlm.nih.gov/pubmed/34123766 http://dx.doi.org/10.5395/rde.2021.46.e30 |
work_keys_str_mv | AT tranxuanvinh microleakageandcharacteristicsofresintoothtissuesinterfaceofaselfetchandanetchandrinseadhesivesystems AT trankhanhquang microleakageandcharacteristicsofresintoothtissuesinterfaceofaselfetchandanetchandrinseadhesivesystems |