Cargando…

The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer

PURPOSE: To investigate the accuracy and dosimetry of 3D-printing non-coplanar template (3D-PNCT)-assisted computed tomography (CT)-guided iodine-125 seed implantation ((125)I-SI) for recurrent chest wall cancer (rCWC). MATERIAL AND METHODS: This was a retrospective study of 19 patients with 22 rCWC...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Weijuan, Chen, Yi, Ji, Zhe, Jiang, Yuliang, Qiu, Bin, Sun, Haitao, Wang, Junjie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170518/
https://www.ncbi.nlm.nih.gov/pubmed/34122566
http://dx.doi.org/10.5114/jcb.2021.106250
_version_ 1783702261961064448
author Jiang, Weijuan
Chen, Yi
Ji, Zhe
Jiang, Yuliang
Qiu, Bin
Sun, Haitao
Wang, Junjie
author_facet Jiang, Weijuan
Chen, Yi
Ji, Zhe
Jiang, Yuliang
Qiu, Bin
Sun, Haitao
Wang, Junjie
author_sort Jiang, Weijuan
collection PubMed
description PURPOSE: To investigate the accuracy and dosimetry of 3D-printing non-coplanar template (3D-PNCT)-assisted computed tomography (CT)-guided iodine-125 seed implantation ((125)I-SI) for recurrent chest wall cancer (rCWC). MATERIAL AND METHODS: This was a retrospective study of 19 patients with 22 rCWC treated with 3D-PNCT-assisted CT-guided (125)I-SI, from Mar 2017 to Mar 2020 in our institute. RESULTS: Mean needle entrance deviation was 4.50 ±2.70 mm, mean angular deviation was 3.40 ±3.10 degrees, and mean depth deviation was 5.20 ±5.20 mm. No significant difference was found for dosimetric parameters (except conformity index) between pre-plan and post-plan; D(90), D(100), V(100), V(150), and V(200) were 157.74 ±24.23 and 151.71 ±33.62 (p = 0.228), 85.36 ±34.09 and 70.46 ±23.48 (p = 0.067), 0.93 ±0.04 and 0.90 ±0.07 (p = 0.068), 0.64 ±0.16 and 0.64 ±0.16 (p = 0.984), and 0.35 ±0.17 and 0.37 ±0.18 (p = 0.382) for pre-plan and post-plan, respectively. Conformity index, external index, and homogeneity index were 0.57 ±0.16 and 0.52 ±0.15 (p = 0.007), 0.73 ±0.55 and 0.79 ±0.53 (p = 0.096), and 0.31 ±0.15 and 0.30 ±0.14 (p = 0.504) for pre-plan and post-plan, respectively. Median follow-up time was 8 months (range, 3-30 months). Complete response was observed in 4/22 (18.1%), partial response in 13/22 (59.1%), stable disease in 4/22 (18.1%), and progression disease in 1/22 (4.5%) of the cancers. Among patients with pain before (125)I-SI, pain relief rate was 87.5% (7/8). No peri-operative complications of more than grade 2 were observed. CONCLUSIONS: 3D-PNCT-assisted CT-guided (125)I-SI may be safe and feasible as palliative therapy for non-surgical candidates and painful patients with rCWC.
format Online
Article
Text
id pubmed-8170518
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-81705182021-06-11 The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer Jiang, Weijuan Chen, Yi Ji, Zhe Jiang, Yuliang Qiu, Bin Sun, Haitao Wang, Junjie J Contemp Brachytherapy Original Paper PURPOSE: To investigate the accuracy and dosimetry of 3D-printing non-coplanar template (3D-PNCT)-assisted computed tomography (CT)-guided iodine-125 seed implantation ((125)I-SI) for recurrent chest wall cancer (rCWC). MATERIAL AND METHODS: This was a retrospective study of 19 patients with 22 rCWC treated with 3D-PNCT-assisted CT-guided (125)I-SI, from Mar 2017 to Mar 2020 in our institute. RESULTS: Mean needle entrance deviation was 4.50 ±2.70 mm, mean angular deviation was 3.40 ±3.10 degrees, and mean depth deviation was 5.20 ±5.20 mm. No significant difference was found for dosimetric parameters (except conformity index) between pre-plan and post-plan; D(90), D(100), V(100), V(150), and V(200) were 157.74 ±24.23 and 151.71 ±33.62 (p = 0.228), 85.36 ±34.09 and 70.46 ±23.48 (p = 0.067), 0.93 ±0.04 and 0.90 ±0.07 (p = 0.068), 0.64 ±0.16 and 0.64 ±0.16 (p = 0.984), and 0.35 ±0.17 and 0.37 ±0.18 (p = 0.382) for pre-plan and post-plan, respectively. Conformity index, external index, and homogeneity index were 0.57 ±0.16 and 0.52 ±0.15 (p = 0.007), 0.73 ±0.55 and 0.79 ±0.53 (p = 0.096), and 0.31 ±0.15 and 0.30 ±0.14 (p = 0.504) for pre-plan and post-plan, respectively. Median follow-up time was 8 months (range, 3-30 months). Complete response was observed in 4/22 (18.1%), partial response in 13/22 (59.1%), stable disease in 4/22 (18.1%), and progression disease in 1/22 (4.5%) of the cancers. Among patients with pain before (125)I-SI, pain relief rate was 87.5% (7/8). No peri-operative complications of more than grade 2 were observed. CONCLUSIONS: 3D-PNCT-assisted CT-guided (125)I-SI may be safe and feasible as palliative therapy for non-surgical candidates and painful patients with rCWC. Termedia Publishing House 2021-05-18 2021-06 /pmc/articles/PMC8170518/ /pubmed/34122566 http://dx.doi.org/10.5114/jcb.2021.106250 Text en Copyright © 2021 Termedia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/ (https://creativecommons.org/licenses/by-nc-sa/4.0/) )
spellingShingle Original Paper
Jiang, Weijuan
Chen, Yi
Ji, Zhe
Jiang, Yuliang
Qiu, Bin
Sun, Haitao
Wang, Junjie
The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer
title The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer
title_full The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer
title_fullStr The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer
title_full_unstemmed The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer
title_short The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer
title_sort accuracy and dosimetric analysis of 3d-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170518/
https://www.ncbi.nlm.nih.gov/pubmed/34122566
http://dx.doi.org/10.5114/jcb.2021.106250
work_keys_str_mv AT jiangweijuan theaccuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT chenyi theaccuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT jizhe theaccuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT jiangyuliang theaccuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT qiubin theaccuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT sunhaitao theaccuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT wangjunjie theaccuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT jiangweijuan accuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT chenyi accuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT jizhe accuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT jiangyuliang accuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT qiubin accuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT sunhaitao accuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer
AT wangjunjie accuracyanddosimetricanalysisof3dprintingnoncoplanartemplateassistediodine125seedimplantationforrecurrentchestwallcancer