Cargando…

Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination

The historical approaches that have been used to establish cleaning validation acceptance limits should be updated to recent approaches to prevent cross contamination. In the present investigation, a cleaning method was validated using high performance liquid chromatography. Method modification crit...

Descripción completa

Detalles Bibliográficos
Autores principales: Lamei Ramandi, Somayeh, Asgharian, Ramin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shaheed Beheshti University of Medical Sciences 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170751/
https://www.ncbi.nlm.nih.gov/pubmed/34400951
http://dx.doi.org/10.22037/ijpr.2020.112734.13922
_version_ 1783702303438536704
author Lamei Ramandi, Somayeh
Asgharian, Ramin
author_facet Lamei Ramandi, Somayeh
Asgharian, Ramin
author_sort Lamei Ramandi, Somayeh
collection PubMed
description The historical approaches that have been used to establish cleaning validation acceptance limits should be updated to recent approaches to prevent cross contamination. In the present investigation, a cleaning method was validated using high performance liquid chromatography. Method modification critical parameters including spiking, swab sampling from PVC, Stainless Steel, and Polyethylene, extraction technique from swab, solubility, potency, toxicity (LD50), and improvement of limit of detection (LOD) of the method through analytical method validation were studied. In addition, roughness, mechanical and electro-polishing, consideration of dosage form as a quantitative factor, acceptable daily exposure (ADE), and permitted daily exposure (PDE) in the worst-case determination were considered in the study. The method was validated based on USP and ICH guidelines for specificity, limit of detection, limit of quantitation, precision, accuracy, linearity, and range. Linear regression analysis of data for the calibration plot in the range of 7.43, 10.89, 21.78, 43.56, 87.12 µg/mL, and relative standard deviation (R.S.D.) found to be 0.5, 0.4, 0.2, and 0.2, respectively with correlation coefficient of R(2) = 0.999997. The LOD and the limit of quantitation (LOQ) were 2.23 and 7.43 µg/mL, respectively. Good recoveries in the range of 73.65-81.20%, and precision with relative standard deviation values lower than 15% have been obtained. The proposed method developed for cleaning validation is specific, precise, and useful for determination of cleaning acceptance limits using health-based limit and Quality Risk Management to develop an appropriate cleaning program for engineering design, safety of patients, and worker protection.
format Online
Article
Text
id pubmed-8170751
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Shaheed Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-81707512021-08-15 Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination Lamei Ramandi, Somayeh Asgharian, Ramin Iran J Pharm Res Original Article The historical approaches that have been used to establish cleaning validation acceptance limits should be updated to recent approaches to prevent cross contamination. In the present investigation, a cleaning method was validated using high performance liquid chromatography. Method modification critical parameters including spiking, swab sampling from PVC, Stainless Steel, and Polyethylene, extraction technique from swab, solubility, potency, toxicity (LD50), and improvement of limit of detection (LOD) of the method through analytical method validation were studied. In addition, roughness, mechanical and electro-polishing, consideration of dosage form as a quantitative factor, acceptable daily exposure (ADE), and permitted daily exposure (PDE) in the worst-case determination were considered in the study. The method was validated based on USP and ICH guidelines for specificity, limit of detection, limit of quantitation, precision, accuracy, linearity, and range. Linear regression analysis of data for the calibration plot in the range of 7.43, 10.89, 21.78, 43.56, 87.12 µg/mL, and relative standard deviation (R.S.D.) found to be 0.5, 0.4, 0.2, and 0.2, respectively with correlation coefficient of R(2) = 0.999997. The LOD and the limit of quantitation (LOQ) were 2.23 and 7.43 µg/mL, respectively. Good recoveries in the range of 73.65-81.20%, and precision with relative standard deviation values lower than 15% have been obtained. The proposed method developed for cleaning validation is specific, precise, and useful for determination of cleaning acceptance limits using health-based limit and Quality Risk Management to develop an appropriate cleaning program for engineering design, safety of patients, and worker protection. Shaheed Beheshti University of Medical Sciences 2021 /pmc/articles/PMC8170751/ /pubmed/34400951 http://dx.doi.org/10.22037/ijpr.2020.112734.13922 Text en https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lamei Ramandi, Somayeh
Asgharian, Ramin
Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination
title Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination
title_full Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination
title_fullStr Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination
title_full_unstemmed Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination
title_short Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination
title_sort determination of cleaning limits considering toxicological risk evaluation to minimize the risk of cross contamination
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170751/
https://www.ncbi.nlm.nih.gov/pubmed/34400951
http://dx.doi.org/10.22037/ijpr.2020.112734.13922
work_keys_str_mv AT lameiramandisomayeh determinationofcleaninglimitsconsideringtoxicologicalriskevaluationtominimizetheriskofcrosscontamination
AT asgharianramin determinationofcleaninglimitsconsideringtoxicologicalriskevaluationtominimizetheriskofcrosscontamination