Cargando…
Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination
The historical approaches that have been used to establish cleaning validation acceptance limits should be updated to recent approaches to prevent cross contamination. In the present investigation, a cleaning method was validated using high performance liquid chromatography. Method modification crit...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shaheed Beheshti University of Medical Sciences
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170751/ https://www.ncbi.nlm.nih.gov/pubmed/34400951 http://dx.doi.org/10.22037/ijpr.2020.112734.13922 |
_version_ | 1783702303438536704 |
---|---|
author | Lamei Ramandi, Somayeh Asgharian, Ramin |
author_facet | Lamei Ramandi, Somayeh Asgharian, Ramin |
author_sort | Lamei Ramandi, Somayeh |
collection | PubMed |
description | The historical approaches that have been used to establish cleaning validation acceptance limits should be updated to recent approaches to prevent cross contamination. In the present investigation, a cleaning method was validated using high performance liquid chromatography. Method modification critical parameters including spiking, swab sampling from PVC, Stainless Steel, and Polyethylene, extraction technique from swab, solubility, potency, toxicity (LD50), and improvement of limit of detection (LOD) of the method through analytical method validation were studied. In addition, roughness, mechanical and electro-polishing, consideration of dosage form as a quantitative factor, acceptable daily exposure (ADE), and permitted daily exposure (PDE) in the worst-case determination were considered in the study. The method was validated based on USP and ICH guidelines for specificity, limit of detection, limit of quantitation, precision, accuracy, linearity, and range. Linear regression analysis of data for the calibration plot in the range of 7.43, 10.89, 21.78, 43.56, 87.12 µg/mL, and relative standard deviation (R.S.D.) found to be 0.5, 0.4, 0.2, and 0.2, respectively with correlation coefficient of R(2) = 0.999997. The LOD and the limit of quantitation (LOQ) were 2.23 and 7.43 µg/mL, respectively. Good recoveries in the range of 73.65-81.20%, and precision with relative standard deviation values lower than 15% have been obtained. The proposed method developed for cleaning validation is specific, precise, and useful for determination of cleaning acceptance limits using health-based limit and Quality Risk Management to develop an appropriate cleaning program for engineering design, safety of patients, and worker protection. |
format | Online Article Text |
id | pubmed-8170751 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Shaheed Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-81707512021-08-15 Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination Lamei Ramandi, Somayeh Asgharian, Ramin Iran J Pharm Res Original Article The historical approaches that have been used to establish cleaning validation acceptance limits should be updated to recent approaches to prevent cross contamination. In the present investigation, a cleaning method was validated using high performance liquid chromatography. Method modification critical parameters including spiking, swab sampling from PVC, Stainless Steel, and Polyethylene, extraction technique from swab, solubility, potency, toxicity (LD50), and improvement of limit of detection (LOD) of the method through analytical method validation were studied. In addition, roughness, mechanical and electro-polishing, consideration of dosage form as a quantitative factor, acceptable daily exposure (ADE), and permitted daily exposure (PDE) in the worst-case determination were considered in the study. The method was validated based on USP and ICH guidelines for specificity, limit of detection, limit of quantitation, precision, accuracy, linearity, and range. Linear regression analysis of data for the calibration plot in the range of 7.43, 10.89, 21.78, 43.56, 87.12 µg/mL, and relative standard deviation (R.S.D.) found to be 0.5, 0.4, 0.2, and 0.2, respectively with correlation coefficient of R(2) = 0.999997. The LOD and the limit of quantitation (LOQ) were 2.23 and 7.43 µg/mL, respectively. Good recoveries in the range of 73.65-81.20%, and precision with relative standard deviation values lower than 15% have been obtained. The proposed method developed for cleaning validation is specific, precise, and useful for determination of cleaning acceptance limits using health-based limit and Quality Risk Management to develop an appropriate cleaning program for engineering design, safety of patients, and worker protection. Shaheed Beheshti University of Medical Sciences 2021 /pmc/articles/PMC8170751/ /pubmed/34400951 http://dx.doi.org/10.22037/ijpr.2020.112734.13922 Text en https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lamei Ramandi, Somayeh Asgharian, Ramin Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination |
title | Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination |
title_full | Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination |
title_fullStr | Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination |
title_full_unstemmed | Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination |
title_short | Determination of Cleaning Limits Considering Toxicological Risk Evaluation to Minimize the Risk of Cross Contamination |
title_sort | determination of cleaning limits considering toxicological risk evaluation to minimize the risk of cross contamination |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170751/ https://www.ncbi.nlm.nih.gov/pubmed/34400951 http://dx.doi.org/10.22037/ijpr.2020.112734.13922 |
work_keys_str_mv | AT lameiramandisomayeh determinationofcleaninglimitsconsideringtoxicologicalriskevaluationtominimizetheriskofcrosscontamination AT asgharianramin determinationofcleaninglimitsconsideringtoxicologicalriskevaluationtominimizetheriskofcrosscontamination |