Cargando…

Comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated COVID-19 resuscitation: A randomized crossover simulation trial

BACKGROUND: Prehospital emergency care of children is challenging. In the era of the COVID-19 pandemic, when medical personnel should use personal protective equipment against aerosol-generating procedures, the efficiency of medical procedures may decrease. The study objective was to evaluate the ef...

Descripción completa

Detalles Bibliográficos
Autores principales: Drozd, Anna, Smereka, Jacek, Pruc, Michal, Malysz, Marek, Gasecka, Aleksandra, Sonmez, Leyla Ozturk, Cyran, Maciej, Konge, Lars, Szarpak, Lukasz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8172272/
https://www.ncbi.nlm.nih.gov/pubmed/34126564
http://dx.doi.org/10.1016/j.ajem.2021.05.080
_version_ 1783702508069191680
author Drozd, Anna
Smereka, Jacek
Pruc, Michal
Malysz, Marek
Gasecka, Aleksandra
Sonmez, Leyla Ozturk
Cyran, Maciej
Konge, Lars
Szarpak, Lukasz
author_facet Drozd, Anna
Smereka, Jacek
Pruc, Michal
Malysz, Marek
Gasecka, Aleksandra
Sonmez, Leyla Ozturk
Cyran, Maciej
Konge, Lars
Szarpak, Lukasz
author_sort Drozd, Anna
collection PubMed
description BACKGROUND: Prehospital emergency care of children is challenging. In the era of the COVID-19 pandemic, when medical personnel should use personal protective equipment against aerosol-generating procedures, the efficiency of medical procedures may decrease. The study objective was to evaluate the effectiveness of different intravascular access methods applied by nurses wearing biosafety Level-2 suits in simulated paediatric COVID-19 resuscitation. METHODS: A prospective, randomized, crossover, single-blinded simulation trial was performed. Nursing staff attending Advanced Cardiovascular Life Support courses accredited by the American Heart Association participated in the study. A total of 65 nurses were recruited and randomly assigned to different study groups. They received standard training on intravascular access methods employing distinct devices. The participants wore biosafety Level-2 suits and performed vascular access with the following intraosseous devices: NIO-P, EZ-IO, and Jamshidi needle; intravenous (IV) access was used as a reference method. Both the order of participants and the access methods were random. Each participant performed intravascular access with each of the four methods tested. The effectiveness of the first attempt to obtain intravascular access and the following time parameters were analysed: the time between grasping the intravascular device out of the original packing until infusion line connection. The ease of the procedure was measured with a visual analogue scale (1 – easy; 10 – difficult). RESULTS: The first attempt success rate of intravascular access by using NIO-P and EZ-IO equalled 100% and was statistically significantly higher than that with the Jamshidi needle (80.0%; p = 0.02) and with the IV method (69.2%; p = 0.005). The time required to connect the infusion line varied and amounted to 33 ± 4 s for NIO-P compared to 37 ± 6.7 s for EZ-IO (p<0.001), 43 ± 7 s for Jamshidi (p<0.001), and 98.5 ± 10 s for IV access (p<0.001). The procedure was easiest in the case of NIO-P and EZ-IO (2 ± 1 points; p=1.0) compared with Jamshidi (5 ± 3 points; p<0.001) and IV access (7 ± 2 points; p<0.001). CONCLUSION: The study provides evidence that nurses wearing biosafety Level-2 suits were able to obtain intraosseous access faster and more effectively as compared with IV access during simulated COVID-19 paediatric resuscitation. The most effective method of intravascular access was the NIO-P intraosseous device. Further clinical trials are necessary to confirm the results.
format Online
Article
Text
id pubmed-8172272
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier Inc.
record_format MEDLINE/PubMed
spelling pubmed-81722722021-06-03 Comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated COVID-19 resuscitation: A randomized crossover simulation trial Drozd, Anna Smereka, Jacek Pruc, Michal Malysz, Marek Gasecka, Aleksandra Sonmez, Leyla Ozturk Cyran, Maciej Konge, Lars Szarpak, Lukasz Am J Emerg Med Article BACKGROUND: Prehospital emergency care of children is challenging. In the era of the COVID-19 pandemic, when medical personnel should use personal protective equipment against aerosol-generating procedures, the efficiency of medical procedures may decrease. The study objective was to evaluate the effectiveness of different intravascular access methods applied by nurses wearing biosafety Level-2 suits in simulated paediatric COVID-19 resuscitation. METHODS: A prospective, randomized, crossover, single-blinded simulation trial was performed. Nursing staff attending Advanced Cardiovascular Life Support courses accredited by the American Heart Association participated in the study. A total of 65 nurses were recruited and randomly assigned to different study groups. They received standard training on intravascular access methods employing distinct devices. The participants wore biosafety Level-2 suits and performed vascular access with the following intraosseous devices: NIO-P, EZ-IO, and Jamshidi needle; intravenous (IV) access was used as a reference method. Both the order of participants and the access methods were random. Each participant performed intravascular access with each of the four methods tested. The effectiveness of the first attempt to obtain intravascular access and the following time parameters were analysed: the time between grasping the intravascular device out of the original packing until infusion line connection. The ease of the procedure was measured with a visual analogue scale (1 – easy; 10 – difficult). RESULTS: The first attempt success rate of intravascular access by using NIO-P and EZ-IO equalled 100% and was statistically significantly higher than that with the Jamshidi needle (80.0%; p = 0.02) and with the IV method (69.2%; p = 0.005). The time required to connect the infusion line varied and amounted to 33 ± 4 s for NIO-P compared to 37 ± 6.7 s for EZ-IO (p<0.001), 43 ± 7 s for Jamshidi (p<0.001), and 98.5 ± 10 s for IV access (p<0.001). The procedure was easiest in the case of NIO-P and EZ-IO (2 ± 1 points; p=1.0) compared with Jamshidi (5 ± 3 points; p<0.001) and IV access (7 ± 2 points; p<0.001). CONCLUSION: The study provides evidence that nurses wearing biosafety Level-2 suits were able to obtain intraosseous access faster and more effectively as compared with IV access during simulated COVID-19 paediatric resuscitation. The most effective method of intravascular access was the NIO-P intraosseous device. Further clinical trials are necessary to confirm the results. Elsevier Inc. 2021-11 2021-06-03 /pmc/articles/PMC8172272/ /pubmed/34126564 http://dx.doi.org/10.1016/j.ajem.2021.05.080 Text en © 2021 Elsevier Inc. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Drozd, Anna
Smereka, Jacek
Pruc, Michal
Malysz, Marek
Gasecka, Aleksandra
Sonmez, Leyla Ozturk
Cyran, Maciej
Konge, Lars
Szarpak, Lukasz
Comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated COVID-19 resuscitation: A randomized crossover simulation trial
title Comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated COVID-19 resuscitation: A randomized crossover simulation trial
title_full Comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated COVID-19 resuscitation: A randomized crossover simulation trial
title_fullStr Comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated COVID-19 resuscitation: A randomized crossover simulation trial
title_full_unstemmed Comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated COVID-19 resuscitation: A randomized crossover simulation trial
title_short Comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated COVID-19 resuscitation: A randomized crossover simulation trial
title_sort comparison of intravascular access methods applied by nurses wearing personal protective equipment in simulated covid-19 resuscitation: a randomized crossover simulation trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8172272/
https://www.ncbi.nlm.nih.gov/pubmed/34126564
http://dx.doi.org/10.1016/j.ajem.2021.05.080
work_keys_str_mv AT drozdanna comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial
AT smerekajacek comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial
AT prucmichal comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial
AT malyszmarek comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial
AT gaseckaaleksandra comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial
AT sonmezleylaozturk comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial
AT cyranmaciej comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial
AT kongelars comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial
AT szarpaklukasz comparisonofintravascularaccessmethodsappliedbynurseswearingpersonalprotectiveequipmentinsimulatedcovid19resuscitationarandomizedcrossoversimulationtrial