Diagnostic Accuracy of PET for Differentiating True Glioma Progression From Post Treatment-Related Changes: A Systematic Review and Meta-Analysis
Purpose: To evaluate the diagnostic accuracy of PET with different radiotracers and parameters in differentiating between true glioma progression (TPR) and post treatment-related change (PTRC). Methods: Studies on using PET to differentiate between TPR and PTRC were screened from the PubMed and Emba...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8173157/ https://www.ncbi.nlm.nih.gov/pubmed/34093419 http://dx.doi.org/10.3389/fneur.2021.671867 |
_version_ | 1783702667400314880 |
---|---|
author | Cui, Meng Zorrilla-Veloz, Rocío Isabel Hu, Jian Guan, Bing Ma, Xiaodong |
author_facet | Cui, Meng Zorrilla-Veloz, Rocío Isabel Hu, Jian Guan, Bing Ma, Xiaodong |
author_sort | Cui, Meng |
collection | PubMed |
description | Purpose: To evaluate the diagnostic accuracy of PET with different radiotracers and parameters in differentiating between true glioma progression (TPR) and post treatment-related change (PTRC). Methods: Studies on using PET to differentiate between TPR and PTRC were screened from the PubMed and Embase databases. By following the PRISMA checklist, the quality assessment of included studies was performed, the true positive and negative values (TP and TN), false positive and negative values (FP and FN), and general characteristics of all the included studies were extracted. Results of PET consistent with reference standard were defined as TP or TN. The pooled sensitivity (Sen), specificity (Spe), and hierarchical summary receiver operating characteristic curves (HSROC) were generated to evaluate the diagnostic accuracy. Results: The 33 included studies had 1,734 patients with 1,811 lesions suspected of glioma recurrence. Fifteen studies tested the accuracy of (18)F-FET PET, 12 tested (18)F-FDG PET, seven tested (11)C-MET PET, and three tested (18)F-DOPA PET. (18)F-FET PET showed a pooled Sen and Spe of 0.88 (95% CI: 0.80, 0.93) and 0.78 (0.69, 0.85), respectively. In the subgroup analysis of FET-PET, diagnostic accuracy of high-grade gliomas (HGGs) was higher than that of mixed-grade gliomas (P(interaction) = 0.04). (18)F-FDG PET showed a pooled Sen and Spe of 0.78 (95% CI: 0.71, 0.83) and 0.87 (0.80, 0.92), the Spe of the HGGs group was lower than that of the low-grade gliomas group (0.82 vs. 0.90, P = 0.02). (11)C-MET PET had a pooled Sen and Spe of 0.92 (95% CI: 0.83, 0.96) and 0.78 (0.69, 0.86). (18)F-DOPA PET had a pooled Sen and Spe of 0.85 (95% CI: 0.80, 0.89) and 0.70 (0.60, 0.79). FET-PET combined with MRI had a pooled Sen and Spe of 0.88 (95% CI: 0.78, 0.94) and 0.76 (0.57, 0.88). Multi-parameters analysis of FET-PET had pooled Sen and Spe values of 0.88 (95% CI: 0.81, 0.92) and 0.79 (0.63, 0.89). Conclusion: PET has a moderate diagnostic accuracy in differentiating between TPR and PTRC. The high Sen of amino acid PET and high Spe of FDG-PET suggest that the combination of commonly used FET-PET and FDG-PET may be more accurate and promising, especially for low-grade glioma. |
format | Online Article Text |
id | pubmed-8173157 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-81731572021-06-04 Diagnostic Accuracy of PET for Differentiating True Glioma Progression From Post Treatment-Related Changes: A Systematic Review and Meta-Analysis Cui, Meng Zorrilla-Veloz, Rocío Isabel Hu, Jian Guan, Bing Ma, Xiaodong Front Neurol Neurology Purpose: To evaluate the diagnostic accuracy of PET with different radiotracers and parameters in differentiating between true glioma progression (TPR) and post treatment-related change (PTRC). Methods: Studies on using PET to differentiate between TPR and PTRC were screened from the PubMed and Embase databases. By following the PRISMA checklist, the quality assessment of included studies was performed, the true positive and negative values (TP and TN), false positive and negative values (FP and FN), and general characteristics of all the included studies were extracted. Results of PET consistent with reference standard were defined as TP or TN. The pooled sensitivity (Sen), specificity (Spe), and hierarchical summary receiver operating characteristic curves (HSROC) were generated to evaluate the diagnostic accuracy. Results: The 33 included studies had 1,734 patients with 1,811 lesions suspected of glioma recurrence. Fifteen studies tested the accuracy of (18)F-FET PET, 12 tested (18)F-FDG PET, seven tested (11)C-MET PET, and three tested (18)F-DOPA PET. (18)F-FET PET showed a pooled Sen and Spe of 0.88 (95% CI: 0.80, 0.93) and 0.78 (0.69, 0.85), respectively. In the subgroup analysis of FET-PET, diagnostic accuracy of high-grade gliomas (HGGs) was higher than that of mixed-grade gliomas (P(interaction) = 0.04). (18)F-FDG PET showed a pooled Sen and Spe of 0.78 (95% CI: 0.71, 0.83) and 0.87 (0.80, 0.92), the Spe of the HGGs group was lower than that of the low-grade gliomas group (0.82 vs. 0.90, P = 0.02). (11)C-MET PET had a pooled Sen and Spe of 0.92 (95% CI: 0.83, 0.96) and 0.78 (0.69, 0.86). (18)F-DOPA PET had a pooled Sen and Spe of 0.85 (95% CI: 0.80, 0.89) and 0.70 (0.60, 0.79). FET-PET combined with MRI had a pooled Sen and Spe of 0.88 (95% CI: 0.78, 0.94) and 0.76 (0.57, 0.88). Multi-parameters analysis of FET-PET had pooled Sen and Spe values of 0.88 (95% CI: 0.81, 0.92) and 0.79 (0.63, 0.89). Conclusion: PET has a moderate diagnostic accuracy in differentiating between TPR and PTRC. The high Sen of amino acid PET and high Spe of FDG-PET suggest that the combination of commonly used FET-PET and FDG-PET may be more accurate and promising, especially for low-grade glioma. Frontiers Media S.A. 2021-05-20 /pmc/articles/PMC8173157/ /pubmed/34093419 http://dx.doi.org/10.3389/fneur.2021.671867 Text en Copyright © 2021 Cui, Zorrilla-Veloz, Hu, Guan and Ma. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Cui, Meng Zorrilla-Veloz, Rocío Isabel Hu, Jian Guan, Bing Ma, Xiaodong Diagnostic Accuracy of PET for Differentiating True Glioma Progression From Post Treatment-Related Changes: A Systematic Review and Meta-Analysis |
title | Diagnostic Accuracy of PET for Differentiating True Glioma Progression From Post Treatment-Related Changes: A Systematic Review and Meta-Analysis |
title_full | Diagnostic Accuracy of PET for Differentiating True Glioma Progression From Post Treatment-Related Changes: A Systematic Review and Meta-Analysis |
title_fullStr | Diagnostic Accuracy of PET for Differentiating True Glioma Progression From Post Treatment-Related Changes: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Diagnostic Accuracy of PET for Differentiating True Glioma Progression From Post Treatment-Related Changes: A Systematic Review and Meta-Analysis |
title_short | Diagnostic Accuracy of PET for Differentiating True Glioma Progression From Post Treatment-Related Changes: A Systematic Review and Meta-Analysis |
title_sort | diagnostic accuracy of pet for differentiating true glioma progression from post treatment-related changes: a systematic review and meta-analysis |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8173157/ https://www.ncbi.nlm.nih.gov/pubmed/34093419 http://dx.doi.org/10.3389/fneur.2021.671867 |
work_keys_str_mv | AT cuimeng diagnosticaccuracyofpetfordifferentiatingtruegliomaprogressionfromposttreatmentrelatedchangesasystematicreviewandmetaanalysis AT zorrillavelozrocioisabel diagnosticaccuracyofpetfordifferentiatingtruegliomaprogressionfromposttreatmentrelatedchangesasystematicreviewandmetaanalysis AT hujian diagnosticaccuracyofpetfordifferentiatingtruegliomaprogressionfromposttreatmentrelatedchangesasystematicreviewandmetaanalysis AT guanbing diagnosticaccuracyofpetfordifferentiatingtruegliomaprogressionfromposttreatmentrelatedchangesasystematicreviewandmetaanalysis AT maxiaodong diagnosticaccuracyofpetfordifferentiatingtruegliomaprogressionfromposttreatmentrelatedchangesasystematicreviewandmetaanalysis |