Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study
BACKGROUND: Mobile 3-dimensional fluoroscopes are an integral part of modern neurosurgical operating theatres and can also be used in combination with free available image post processing to depict cerebral vessels. In preparation of stereotactic surgery, preoperative Computed Tomography (CT) may be...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8173902/ https://www.ncbi.nlm.nih.gov/pubmed/34082701 http://dx.doi.org/10.1186/s12880-021-00622-3 |
_version_ | 1783702801472290816 |
---|---|
author | Linsenmann, Thomas Cattaneo, Andrea März, Alexander Weiland, Judith Stetter, Christian Nickl, Robert Westermaier, Thomas |
author_facet | Linsenmann, Thomas Cattaneo, Andrea März, Alexander Weiland, Judith Stetter, Christian Nickl, Robert Westermaier, Thomas |
author_sort | Linsenmann, Thomas |
collection | PubMed |
description | BACKGROUND: Mobile 3-dimensional fluoroscopes are an integral part of modern neurosurgical operating theatres and can also be used in combination with free available image post processing to depict cerebral vessels. In preparation of stereotactic surgery, preoperative Computed Tomography (CT) may be required for image fusion. Contrast CT may be of further advantage for image fusion as it regards the vessel anatomy in trajectory planning. Time-consuming in-hospital transports are necessary for this purpose. Mobile 3D-fluoroscopes may be used to generate a CT equal preoperative data set without an in-hospital transport. This study was performed to determine the feasibility and image quality of intraoperative 3-dimensional fluoroscopy with intravenous contrast administration in combination with stereotactical procedures. METHODS: 6 patients were included in this feasibility study. After fixation in a radiolucent Mayfield clamp a rotational fluoroscopy scan was performed with 50 mL iodine contrast agent. The image data sets were merged with the existing MRI images at a planning station and visually evaluated by two observer. The operation times were compared between the frame-based and frameless systems (“skin-to-skin” and “OR entry to exit”). RESULTS: The procedure proves to be safe. The entire procedure from fluoroscope positioning to the transfer to the planning station took 5–6 min with an image acquisition time of 24 s. In 5 of 6 cases, the fused imaging was able to reproduce the vascular anatomy accurately and in good quality. Both time end-points were significantly shorter compared to frame-based interventions. CONCLUSION: The images could easily be transferred to the planning and navigation system and were successfully merged with the MRI data set. The procedure can be completely integrated into the surgical workflow. Preoperative CT imaging or transport under anaesthesia may even be replaced by this technique in the future. Furthermore, hemorrhages can be successfully visualized intraoperatively and might prevent time delays in emergencies. |
format | Online Article Text |
id | pubmed-8173902 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-81739022021-06-03 Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study Linsenmann, Thomas Cattaneo, Andrea März, Alexander Weiland, Judith Stetter, Christian Nickl, Robert Westermaier, Thomas BMC Med Imaging Research Article BACKGROUND: Mobile 3-dimensional fluoroscopes are an integral part of modern neurosurgical operating theatres and can also be used in combination with free available image post processing to depict cerebral vessels. In preparation of stereotactic surgery, preoperative Computed Tomography (CT) may be required for image fusion. Contrast CT may be of further advantage for image fusion as it regards the vessel anatomy in trajectory planning. Time-consuming in-hospital transports are necessary for this purpose. Mobile 3D-fluoroscopes may be used to generate a CT equal preoperative data set without an in-hospital transport. This study was performed to determine the feasibility and image quality of intraoperative 3-dimensional fluoroscopy with intravenous contrast administration in combination with stereotactical procedures. METHODS: 6 patients were included in this feasibility study. After fixation in a radiolucent Mayfield clamp a rotational fluoroscopy scan was performed with 50 mL iodine contrast agent. The image data sets were merged with the existing MRI images at a planning station and visually evaluated by two observer. The operation times were compared between the frame-based and frameless systems (“skin-to-skin” and “OR entry to exit”). RESULTS: The procedure proves to be safe. The entire procedure from fluoroscope positioning to the transfer to the planning station took 5–6 min with an image acquisition time of 24 s. In 5 of 6 cases, the fused imaging was able to reproduce the vascular anatomy accurately and in good quality. Both time end-points were significantly shorter compared to frame-based interventions. CONCLUSION: The images could easily be transferred to the planning and navigation system and were successfully merged with the MRI data set. The procedure can be completely integrated into the surgical workflow. Preoperative CT imaging or transport under anaesthesia may even be replaced by this technique in the future. Furthermore, hemorrhages can be successfully visualized intraoperatively and might prevent time delays in emergencies. BioMed Central 2021-06-03 /pmc/articles/PMC8173902/ /pubmed/34082701 http://dx.doi.org/10.1186/s12880-021-00622-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Linsenmann, Thomas Cattaneo, Andrea März, Alexander Weiland, Judith Stetter, Christian Nickl, Robert Westermaier, Thomas Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study |
title | Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study |
title_full | Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study |
title_fullStr | Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study |
title_full_unstemmed | Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study |
title_short | Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study |
title_sort | combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3d-rotational fluoroscopy with intravenous contrast administration: a feasibility study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8173902/ https://www.ncbi.nlm.nih.gov/pubmed/34082701 http://dx.doi.org/10.1186/s12880-021-00622-3 |
work_keys_str_mv | AT linsenmannthomas combinedframelessstereotacticalbiopsyandintraoperativecerebralangiographyby3drotationalfluoroscopywithintravenouscontrastadministrationafeasibilitystudy AT cattaneoandrea combinedframelessstereotacticalbiopsyandintraoperativecerebralangiographyby3drotationalfluoroscopywithintravenouscontrastadministrationafeasibilitystudy AT marzalexander combinedframelessstereotacticalbiopsyandintraoperativecerebralangiographyby3drotationalfluoroscopywithintravenouscontrastadministrationafeasibilitystudy AT weilandjudith combinedframelessstereotacticalbiopsyandintraoperativecerebralangiographyby3drotationalfluoroscopywithintravenouscontrastadministrationafeasibilitystudy AT stetterchristian combinedframelessstereotacticalbiopsyandintraoperativecerebralangiographyby3drotationalfluoroscopywithintravenouscontrastadministrationafeasibilitystudy AT nicklrobert combinedframelessstereotacticalbiopsyandintraoperativecerebralangiographyby3drotationalfluoroscopywithintravenouscontrastadministrationafeasibilitystudy AT westermaierthomas combinedframelessstereotacticalbiopsyandintraoperativecerebralangiographyby3drotationalfluoroscopywithintravenouscontrastadministrationafeasibilitystudy |