Cargando…

Bystander Cardiopulmonary Resuscitation Quality: Potential for Improvements in Cardiac Arrest Resuscitation

BACKGROUND: Bystander cardiopulmonary resuscitation (CPR) is a critical intervention to improve survival following out‐of‐hospital cardiac arrest. We evaluated the quality of bystander CPR and whether performance varied according to the number of bystanders or provision of telecommunicator CPR (TCPR...

Descripción completa

Detalles Bibliográficos
Autores principales: Chocron, Richard, Jobe, Julia, Guan, Sally, Kim, Madeleine, Shigemura, Mia, Fahrenbruch, Carol, Rea, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8174211/
https://www.ncbi.nlm.nih.gov/pubmed/33660519
http://dx.doi.org/10.1161/JAHA.120.017930
_version_ 1783702858657431552
author Chocron, Richard
Jobe, Julia
Guan, Sally
Kim, Madeleine
Shigemura, Mia
Fahrenbruch, Carol
Rea, Thomas
author_facet Chocron, Richard
Jobe, Julia
Guan, Sally
Kim, Madeleine
Shigemura, Mia
Fahrenbruch, Carol
Rea, Thomas
author_sort Chocron, Richard
collection PubMed
description BACKGROUND: Bystander cardiopulmonary resuscitation (CPR) is a critical intervention to improve survival following out‐of‐hospital cardiac arrest. We evaluated the quality of bystander CPR and whether performance varied according to the number of bystanders or provision of telecommunicator CPR (TCPR). METHODS AND RESULTS: We investigated non‐traumatic out‐of‐hospital cardiac arrest occurring in a large metropolitan emergency medical system during a 6‐month period. Information about bystander care was ascertained through review of the 9‐1‐1 recordings in addition to emergency medical system and hospital records to determine bystander CPR status (none versus TCPR versus unassisted), the number of bystanders on‐scene, and CPR performance metrics of compression fraction and compression rate. Of the 428 eligible out‐of‐hospital cardiac arrest, 76.4% received bystander CPR including 43.7% unassisted CPR and 56.3% TCPR; 35.2% had one bystander, 33.3% had 2 bystanders, and 31.5% had ≥3 bystanders. Overall compression fraction was 59% with a compression rate of 88 per minute. CPR differed according to TCPR status (fraction=52%, rate=87 per minute for TCPR versus fraction=69%, rate=102 for unassisted CPR, P<0.05 for each comparison) and the number of bystanders (fraction=55%, rate=87 per minute for 1 bystander, fraction=59%, rate=89 for 2 bystanders, fraction=65%, rate=97 for ≥3 bystanders, test for trend P<0.05 for each metric). Additional bystander actions were uncommon to include rotation of compressors (3.1%) or application of an automated external defibrillator (8.0%). CONCLUSIONS: Bystander CPR quality as gauged by compression fraction and rate approached guideline goals though performance depended upon the type of CPR and number of bystanders.
format Online
Article
Text
id pubmed-8174211
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-81742112021-06-11 Bystander Cardiopulmonary Resuscitation Quality: Potential for Improvements in Cardiac Arrest Resuscitation Chocron, Richard Jobe, Julia Guan, Sally Kim, Madeleine Shigemura, Mia Fahrenbruch, Carol Rea, Thomas J Am Heart Assoc Original Research BACKGROUND: Bystander cardiopulmonary resuscitation (CPR) is a critical intervention to improve survival following out‐of‐hospital cardiac arrest. We evaluated the quality of bystander CPR and whether performance varied according to the number of bystanders or provision of telecommunicator CPR (TCPR). METHODS AND RESULTS: We investigated non‐traumatic out‐of‐hospital cardiac arrest occurring in a large metropolitan emergency medical system during a 6‐month period. Information about bystander care was ascertained through review of the 9‐1‐1 recordings in addition to emergency medical system and hospital records to determine bystander CPR status (none versus TCPR versus unassisted), the number of bystanders on‐scene, and CPR performance metrics of compression fraction and compression rate. Of the 428 eligible out‐of‐hospital cardiac arrest, 76.4% received bystander CPR including 43.7% unassisted CPR and 56.3% TCPR; 35.2% had one bystander, 33.3% had 2 bystanders, and 31.5% had ≥3 bystanders. Overall compression fraction was 59% with a compression rate of 88 per minute. CPR differed according to TCPR status (fraction=52%, rate=87 per minute for TCPR versus fraction=69%, rate=102 for unassisted CPR, P<0.05 for each comparison) and the number of bystanders (fraction=55%, rate=87 per minute for 1 bystander, fraction=59%, rate=89 for 2 bystanders, fraction=65%, rate=97 for ≥3 bystanders, test for trend P<0.05 for each metric). Additional bystander actions were uncommon to include rotation of compressors (3.1%) or application of an automated external defibrillator (8.0%). CONCLUSIONS: Bystander CPR quality as gauged by compression fraction and rate approached guideline goals though performance depended upon the type of CPR and number of bystanders. John Wiley and Sons Inc. 2021-03-04 /pmc/articles/PMC8174211/ /pubmed/33660519 http://dx.doi.org/10.1161/JAHA.120.017930 Text en © 2021 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Research
Chocron, Richard
Jobe, Julia
Guan, Sally
Kim, Madeleine
Shigemura, Mia
Fahrenbruch, Carol
Rea, Thomas
Bystander Cardiopulmonary Resuscitation Quality: Potential for Improvements in Cardiac Arrest Resuscitation
title Bystander Cardiopulmonary Resuscitation Quality: Potential for Improvements in Cardiac Arrest Resuscitation
title_full Bystander Cardiopulmonary Resuscitation Quality: Potential for Improvements in Cardiac Arrest Resuscitation
title_fullStr Bystander Cardiopulmonary Resuscitation Quality: Potential for Improvements in Cardiac Arrest Resuscitation
title_full_unstemmed Bystander Cardiopulmonary Resuscitation Quality: Potential for Improvements in Cardiac Arrest Resuscitation
title_short Bystander Cardiopulmonary Resuscitation Quality: Potential for Improvements in Cardiac Arrest Resuscitation
title_sort bystander cardiopulmonary resuscitation quality: potential for improvements in cardiac arrest resuscitation
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8174211/
https://www.ncbi.nlm.nih.gov/pubmed/33660519
http://dx.doi.org/10.1161/JAHA.120.017930
work_keys_str_mv AT chocronrichard bystandercardiopulmonaryresuscitationqualitypotentialforimprovementsincardiacarrestresuscitation
AT jobejulia bystandercardiopulmonaryresuscitationqualitypotentialforimprovementsincardiacarrestresuscitation
AT guansally bystandercardiopulmonaryresuscitationqualitypotentialforimprovementsincardiacarrestresuscitation
AT kimmadeleine bystandercardiopulmonaryresuscitationqualitypotentialforimprovementsincardiacarrestresuscitation
AT shigemuramia bystandercardiopulmonaryresuscitationqualitypotentialforimprovementsincardiacarrestresuscitation
AT fahrenbruchcarol bystandercardiopulmonaryresuscitationqualitypotentialforimprovementsincardiacarrestresuscitation
AT reathomas bystandercardiopulmonaryresuscitationqualitypotentialforimprovementsincardiacarrestresuscitation