Cargando…

Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope

BACKGROUND AND AIMS: Glidescope®videolaryngoscope (GVL) is a video intubation system with 60° angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The a...

Descripción completa

Detalles Bibliográficos
Autores principales: Meshram, Tanvi M, Ramachandran, Rashmi, Trikha, Anjan, Rewari, Vimi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8174590/
https://www.ncbi.nlm.nih.gov/pubmed/34103747
http://dx.doi.org/10.4103/ija.IJA_417_20
_version_ 1783702936869666816
author Meshram, Tanvi M
Ramachandran, Rashmi
Trikha, Anjan
Rewari, Vimi
author_facet Meshram, Tanvi M
Ramachandran, Rashmi
Trikha, Anjan
Rewari, Vimi
author_sort Meshram, Tanvi M
collection PubMed
description BACKGROUND AND AIMS: Glidescope®videolaryngoscope (GVL) is a video intubation system with 60° angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The aim of this study was to compare haemodynamic responses (blood pressure and heart rate) and airway morbidity using the Macintosh direct laryngoscope (MDL) and the Glidescope®videolaryngoscope (GVL) in hypertensive patients. METHODS: Fifty patients with hypertension controlled on antihypertensive medications scheduled for elective surgery under general anaesthesia were randomly assigned to group GVL (n = 25) or group MDL (n = 25). Heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) were recorded at baseline, after induction, pre-intubation, at intubation, 1, 2, 3, 4, and 5 min after intubation. Time to intubation, number of attempts, complications during intubation, and postoperative airway complications (sore throat, hoarseness, dysphagia, and cough) were also recorded. RESULTS: There was a statistically significant increase in SBP, DBP, and MBP at intubation [(P = 0.003, 0.013, 0.03), 1 min (P = 0.001, 0.012, 0.02), 2 min (P = 0.04, 0.02, 0.04), and 3 min (P = 0.02, 0.01)] in the MDL group as compared to GVL group. The time to intubate was significantly greater in the GVL group as compared to MDL group (P = 0.0006). There was no significant difference in the incidence of intraoperative and postoperative airway complications. CONCLUSION: In the hands of an experienced anaesthesiologist, the use of GVL in controlled hypertensive patients is associated with less haemodynamic response as compared to Macintosh Laryngoscope without any increase in airway complications.
format Online
Article
Text
id pubmed-8174590
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-81745902021-06-07 Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope Meshram, Tanvi M Ramachandran, Rashmi Trikha, Anjan Rewari, Vimi Indian J Anaesth Original Article BACKGROUND AND AIMS: Glidescope®videolaryngoscope (GVL) is a video intubation system with 60° angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The aim of this study was to compare haemodynamic responses (blood pressure and heart rate) and airway morbidity using the Macintosh direct laryngoscope (MDL) and the Glidescope®videolaryngoscope (GVL) in hypertensive patients. METHODS: Fifty patients with hypertension controlled on antihypertensive medications scheduled for elective surgery under general anaesthesia were randomly assigned to group GVL (n = 25) or group MDL (n = 25). Heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) were recorded at baseline, after induction, pre-intubation, at intubation, 1, 2, 3, 4, and 5 min after intubation. Time to intubation, number of attempts, complications during intubation, and postoperative airway complications (sore throat, hoarseness, dysphagia, and cough) were also recorded. RESULTS: There was a statistically significant increase in SBP, DBP, and MBP at intubation [(P = 0.003, 0.013, 0.03), 1 min (P = 0.001, 0.012, 0.02), 2 min (P = 0.04, 0.02, 0.04), and 3 min (P = 0.02, 0.01)] in the MDL group as compared to GVL group. The time to intubate was significantly greater in the GVL group as compared to MDL group (P = 0.0006). There was no significant difference in the incidence of intraoperative and postoperative airway complications. CONCLUSION: In the hands of an experienced anaesthesiologist, the use of GVL in controlled hypertensive patients is associated with less haemodynamic response as compared to Macintosh Laryngoscope without any increase in airway complications. Wolters Kluwer - Medknow 2021-04 2021-04-15 /pmc/articles/PMC8174590/ /pubmed/34103747 http://dx.doi.org/10.4103/ija.IJA_417_20 Text en Copyright: © 2021 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Meshram, Tanvi M
Ramachandran, Rashmi
Trikha, Anjan
Rewari, Vimi
Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope
title Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope
title_full Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope
title_fullStr Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope
title_full_unstemmed Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope
title_short Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope
title_sort haemodynamic responses following orotracheal intubation in patients with hypertension---macintosh direct laryngoscope versus glidescope®videolaryngoscope
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8174590/
https://www.ncbi.nlm.nih.gov/pubmed/34103747
http://dx.doi.org/10.4103/ija.IJA_417_20
work_keys_str_mv AT meshramtanvim haemodynamicresponsesfollowingorotrachealintubationinpatientswithhypertensionmacintoshdirectlaryngoscopeversusglidescopevideolaryngoscope
AT ramachandranrashmi haemodynamicresponsesfollowingorotrachealintubationinpatientswithhypertensionmacintoshdirectlaryngoscopeversusglidescopevideolaryngoscope
AT trikhaanjan haemodynamicresponsesfollowingorotrachealintubationinpatientswithhypertensionmacintoshdirectlaryngoscopeversusglidescopevideolaryngoscope
AT rewarivimi haemodynamicresponsesfollowingorotrachealintubationinpatientswithhypertensionmacintoshdirectlaryngoscopeversusglidescopevideolaryngoscope