Cargando…
Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope
BACKGROUND AND AIMS: Glidescope®videolaryngoscope (GVL) is a video intubation system with 60° angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8174590/ https://www.ncbi.nlm.nih.gov/pubmed/34103747 http://dx.doi.org/10.4103/ija.IJA_417_20 |
_version_ | 1783702936869666816 |
---|---|
author | Meshram, Tanvi M Ramachandran, Rashmi Trikha, Anjan Rewari, Vimi |
author_facet | Meshram, Tanvi M Ramachandran, Rashmi Trikha, Anjan Rewari, Vimi |
author_sort | Meshram, Tanvi M |
collection | PubMed |
description | BACKGROUND AND AIMS: Glidescope®videolaryngoscope (GVL) is a video intubation system with 60° angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The aim of this study was to compare haemodynamic responses (blood pressure and heart rate) and airway morbidity using the Macintosh direct laryngoscope (MDL) and the Glidescope®videolaryngoscope (GVL) in hypertensive patients. METHODS: Fifty patients with hypertension controlled on antihypertensive medications scheduled for elective surgery under general anaesthesia were randomly assigned to group GVL (n = 25) or group MDL (n = 25). Heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) were recorded at baseline, after induction, pre-intubation, at intubation, 1, 2, 3, 4, and 5 min after intubation. Time to intubation, number of attempts, complications during intubation, and postoperative airway complications (sore throat, hoarseness, dysphagia, and cough) were also recorded. RESULTS: There was a statistically significant increase in SBP, DBP, and MBP at intubation [(P = 0.003, 0.013, 0.03), 1 min (P = 0.001, 0.012, 0.02), 2 min (P = 0.04, 0.02, 0.04), and 3 min (P = 0.02, 0.01)] in the MDL group as compared to GVL group. The time to intubate was significantly greater in the GVL group as compared to MDL group (P = 0.0006). There was no significant difference in the incidence of intraoperative and postoperative airway complications. CONCLUSION: In the hands of an experienced anaesthesiologist, the use of GVL in controlled hypertensive patients is associated with less haemodynamic response as compared to Macintosh Laryngoscope without any increase in airway complications. |
format | Online Article Text |
id | pubmed-8174590 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-81745902021-06-07 Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope Meshram, Tanvi M Ramachandran, Rashmi Trikha, Anjan Rewari, Vimi Indian J Anaesth Original Article BACKGROUND AND AIMS: Glidescope®videolaryngoscope (GVL) is a video intubation system with 60° angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The aim of this study was to compare haemodynamic responses (blood pressure and heart rate) and airway morbidity using the Macintosh direct laryngoscope (MDL) and the Glidescope®videolaryngoscope (GVL) in hypertensive patients. METHODS: Fifty patients with hypertension controlled on antihypertensive medications scheduled for elective surgery under general anaesthesia were randomly assigned to group GVL (n = 25) or group MDL (n = 25). Heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) were recorded at baseline, after induction, pre-intubation, at intubation, 1, 2, 3, 4, and 5 min after intubation. Time to intubation, number of attempts, complications during intubation, and postoperative airway complications (sore throat, hoarseness, dysphagia, and cough) were also recorded. RESULTS: There was a statistically significant increase in SBP, DBP, and MBP at intubation [(P = 0.003, 0.013, 0.03), 1 min (P = 0.001, 0.012, 0.02), 2 min (P = 0.04, 0.02, 0.04), and 3 min (P = 0.02, 0.01)] in the MDL group as compared to GVL group. The time to intubate was significantly greater in the GVL group as compared to MDL group (P = 0.0006). There was no significant difference in the incidence of intraoperative and postoperative airway complications. CONCLUSION: In the hands of an experienced anaesthesiologist, the use of GVL in controlled hypertensive patients is associated with less haemodynamic response as compared to Macintosh Laryngoscope without any increase in airway complications. Wolters Kluwer - Medknow 2021-04 2021-04-15 /pmc/articles/PMC8174590/ /pubmed/34103747 http://dx.doi.org/10.4103/ija.IJA_417_20 Text en Copyright: © 2021 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Meshram, Tanvi M Ramachandran, Rashmi Trikha, Anjan Rewari, Vimi Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope |
title | Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope |
title_full | Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope |
title_fullStr | Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope |
title_full_unstemmed | Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope |
title_short | Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope®videolaryngoscope |
title_sort | haemodynamic responses following orotracheal intubation in patients with hypertension---macintosh direct laryngoscope versus glidescope®videolaryngoscope |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8174590/ https://www.ncbi.nlm.nih.gov/pubmed/34103747 http://dx.doi.org/10.4103/ija.IJA_417_20 |
work_keys_str_mv | AT meshramtanvim haemodynamicresponsesfollowingorotrachealintubationinpatientswithhypertensionmacintoshdirectlaryngoscopeversusglidescopevideolaryngoscope AT ramachandranrashmi haemodynamicresponsesfollowingorotrachealintubationinpatientswithhypertensionmacintoshdirectlaryngoscopeversusglidescopevideolaryngoscope AT trikhaanjan haemodynamicresponsesfollowingorotrachealintubationinpatientswithhypertensionmacintoshdirectlaryngoscopeversusglidescopevideolaryngoscope AT rewarivimi haemodynamicresponsesfollowingorotrachealintubationinpatientswithhypertensionmacintoshdirectlaryngoscopeversusglidescopevideolaryngoscope |