Cargando…
Evaluation of biases in remote photoplethysmography methods
This work investigates the estimation biases of remote photoplethysmography (rPPG) methods for pulse rate measurement across diverse demographics. Advances in photoplethysmography (PPG) and rPPG methods have enabled the development of contact and noncontact approaches for continuous monitoring and c...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8175478/ https://www.ncbi.nlm.nih.gov/pubmed/34083724 http://dx.doi.org/10.1038/s41746-021-00462-z |
_version_ | 1783703062590783488 |
---|---|
author | Dasari, Ananyananda Prakash, Sakthi Kumar Arul Jeni, László A. Tucker, Conrad S. |
author_facet | Dasari, Ananyananda Prakash, Sakthi Kumar Arul Jeni, László A. Tucker, Conrad S. |
author_sort | Dasari, Ananyananda |
collection | PubMed |
description | This work investigates the estimation biases of remote photoplethysmography (rPPG) methods for pulse rate measurement across diverse demographics. Advances in photoplethysmography (PPG) and rPPG methods have enabled the development of contact and noncontact approaches for continuous monitoring and collection of patient health data. The contagious nature of viruses such as COVID-19 warrants noncontact methods for physiological signal estimation. However, these approaches are subject to estimation biases due to variations in environmental conditions and subject demographics. The performance of contact-based wearable sensors has been evaluated, using off-the-shelf devices across demographics. However, the measurement uncertainty of rPPG methods that estimate pulse rate has not been sufficiently tested across diverse demographic populations or environments. Quantifying the efficacy of rPPG methods in real-world conditions is critical in determining their potential viability as health monitoring solutions. Currently, publicly available face datasets accompanied by physiological measurements are typically captured in controlled laboratory settings, lacking diversity in subject skin tones, age, and cultural artifacts (e.g, bindi worn by Indian women). In this study, we collect pulse rate and facial video data from human subjects in India and Sierra Leone, in order to quantify the uncertainty in noncontact pulse rate estimation methods. The video data are used to estimate pulse rate using state-of-the-art rPPG camera-based methods, and compared against ground truth measurements captured using an FDA-approved contact-based pulse rate measurement device. Our study reveals that rPPG methods exhibit similar biases when compared with a contact-based device across demographic groups and environmental conditions. The mean difference between pulse rates measured by rPPG methods and the ground truth is found to be ~2% (1 beats per minute (b.p.m.)), signifying agreement of rPPG methods with the ground truth. We also find that rPPG methods show pulse rate variability of ~15% (11 b.p.m.), as compared to the ground truth. We investigate factors impacting rPPG methods and discuss solutions aimed at mitigating variance. |
format | Online Article Text |
id | pubmed-8175478 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-81754782021-06-07 Evaluation of biases in remote photoplethysmography methods Dasari, Ananyananda Prakash, Sakthi Kumar Arul Jeni, László A. Tucker, Conrad S. NPJ Digit Med Article This work investigates the estimation biases of remote photoplethysmography (rPPG) methods for pulse rate measurement across diverse demographics. Advances in photoplethysmography (PPG) and rPPG methods have enabled the development of contact and noncontact approaches for continuous monitoring and collection of patient health data. The contagious nature of viruses such as COVID-19 warrants noncontact methods for physiological signal estimation. However, these approaches are subject to estimation biases due to variations in environmental conditions and subject demographics. The performance of contact-based wearable sensors has been evaluated, using off-the-shelf devices across demographics. However, the measurement uncertainty of rPPG methods that estimate pulse rate has not been sufficiently tested across diverse demographic populations or environments. Quantifying the efficacy of rPPG methods in real-world conditions is critical in determining their potential viability as health monitoring solutions. Currently, publicly available face datasets accompanied by physiological measurements are typically captured in controlled laboratory settings, lacking diversity in subject skin tones, age, and cultural artifacts (e.g, bindi worn by Indian women). In this study, we collect pulse rate and facial video data from human subjects in India and Sierra Leone, in order to quantify the uncertainty in noncontact pulse rate estimation methods. The video data are used to estimate pulse rate using state-of-the-art rPPG camera-based methods, and compared against ground truth measurements captured using an FDA-approved contact-based pulse rate measurement device. Our study reveals that rPPG methods exhibit similar biases when compared with a contact-based device across demographic groups and environmental conditions. The mean difference between pulse rates measured by rPPG methods and the ground truth is found to be ~2% (1 beats per minute (b.p.m.)), signifying agreement of rPPG methods with the ground truth. We also find that rPPG methods show pulse rate variability of ~15% (11 b.p.m.), as compared to the ground truth. We investigate factors impacting rPPG methods and discuss solutions aimed at mitigating variance. Nature Publishing Group UK 2021-06-03 /pmc/articles/PMC8175478/ /pubmed/34083724 http://dx.doi.org/10.1038/s41746-021-00462-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Dasari, Ananyananda Prakash, Sakthi Kumar Arul Jeni, László A. Tucker, Conrad S. Evaluation of biases in remote photoplethysmography methods |
title | Evaluation of biases in remote photoplethysmography methods |
title_full | Evaluation of biases in remote photoplethysmography methods |
title_fullStr | Evaluation of biases in remote photoplethysmography methods |
title_full_unstemmed | Evaluation of biases in remote photoplethysmography methods |
title_short | Evaluation of biases in remote photoplethysmography methods |
title_sort | evaluation of biases in remote photoplethysmography methods |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8175478/ https://www.ncbi.nlm.nih.gov/pubmed/34083724 http://dx.doi.org/10.1038/s41746-021-00462-z |
work_keys_str_mv | AT dasariananyananda evaluationofbiasesinremotephotoplethysmographymethods AT prakashsakthikumararul evaluationofbiasesinremotephotoplethysmographymethods AT jenilaszloa evaluationofbiasesinremotephotoplethysmographymethods AT tuckerconrads evaluationofbiasesinremotephotoplethysmographymethods |