Cargando…

Evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering

Two series of binary graft cationic starch-based flocculants (CS-DMCs and CS-DMLs) with different hydrophilicity and charge density (CD) were prepared by graft copolymerization of acrylamide with 2-(Methacryloyloxy)-N,N,N-trimethylethanaminium chloride and methacrylic acid 2-(benzyldimethylaminio) e...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Pan, Shen, Shaohang, Yang, Hu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8175719/
https://www.ncbi.nlm.nih.gov/pubmed/34083668
http://dx.doi.org/10.1038/s41598-021-91323-y
_version_ 1783703103261900800
author Hu, Pan
Shen, Shaohang
Yang, Hu
author_facet Hu, Pan
Shen, Shaohang
Yang, Hu
author_sort Hu, Pan
collection PubMed
description Two series of binary graft cationic starch-based flocculants (CS-DMCs and CS-DMLs) with different hydrophilicity and charge density (CD) were prepared by graft copolymerization of acrylamide with 2-(Methacryloyloxy)-N,N,N-trimethylethanaminium chloride and methacrylic acid 2-(benzyldimethylaminio) ethyl chloride, respectively, on the starch (St) backbone. The sludge dewatering performance of CS-DMCs and CS-DMLs were evaluated and compared based on the changes in filter cake moisture content (FCMC), specific resistance of filtration (SRF), fractions and components of extracellular polymeric substances, and various physiochemical characteristics of sludge flocs and cakes. Increase in CD of the St-based flocculants caused improved sludge dewaterability. Under the similar CD, CS-DML with relatively high hydrophobicity exhibited lower FCMC and SRF, larger and denser sludge flocs, and better permeability of sludge cakes than CS-DMCs due to the synergistic effects of charge neutralization, bridging flocculation and hydrophobic association. Furthermore, a second-order polynomial model on the basis of phenomenological theory was successfully applied to quantitatively evaluate the influences of the two important structural factors of these St-based flocculants, i.e., hydrophobicity and CD, on the sludge dewaterability. The structure–activity relationship of the St-based flocculants in sludge dewatering was obtained according to the theoretic simulation. The dewatering mechanisms was discussed in depth on the basis of the experimental and simulated results; besides, the FCMC and optimal dose can be predicted by the established structure–activity relationship. This current work offered a novel and valuable way to exploit and design of low-cost and high-performance graft natural polymeric flocculants applied in efficient conditioning of sludge.
format Online
Article
Text
id pubmed-8175719
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-81757192021-06-07 Evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering Hu, Pan Shen, Shaohang Yang, Hu Sci Rep Article Two series of binary graft cationic starch-based flocculants (CS-DMCs and CS-DMLs) with different hydrophilicity and charge density (CD) were prepared by graft copolymerization of acrylamide with 2-(Methacryloyloxy)-N,N,N-trimethylethanaminium chloride and methacrylic acid 2-(benzyldimethylaminio) ethyl chloride, respectively, on the starch (St) backbone. The sludge dewatering performance of CS-DMCs and CS-DMLs were evaluated and compared based on the changes in filter cake moisture content (FCMC), specific resistance of filtration (SRF), fractions and components of extracellular polymeric substances, and various physiochemical characteristics of sludge flocs and cakes. Increase in CD of the St-based flocculants caused improved sludge dewaterability. Under the similar CD, CS-DML with relatively high hydrophobicity exhibited lower FCMC and SRF, larger and denser sludge flocs, and better permeability of sludge cakes than CS-DMCs due to the synergistic effects of charge neutralization, bridging flocculation and hydrophobic association. Furthermore, a second-order polynomial model on the basis of phenomenological theory was successfully applied to quantitatively evaluate the influences of the two important structural factors of these St-based flocculants, i.e., hydrophobicity and CD, on the sludge dewaterability. The structure–activity relationship of the St-based flocculants in sludge dewatering was obtained according to the theoretic simulation. The dewatering mechanisms was discussed in depth on the basis of the experimental and simulated results; besides, the FCMC and optimal dose can be predicted by the established structure–activity relationship. This current work offered a novel and valuable way to exploit and design of low-cost and high-performance graft natural polymeric flocculants applied in efficient conditioning of sludge. Nature Publishing Group UK 2021-06-03 /pmc/articles/PMC8175719/ /pubmed/34083668 http://dx.doi.org/10.1038/s41598-021-91323-y Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Hu, Pan
Shen, Shaohang
Yang, Hu
Evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering
title Evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering
title_full Evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering
title_fullStr Evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering
title_full_unstemmed Evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering
title_short Evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering
title_sort evaluation of hydrophobically associating cationic starch-based flocculants in sludge dewatering
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8175719/
https://www.ncbi.nlm.nih.gov/pubmed/34083668
http://dx.doi.org/10.1038/s41598-021-91323-y
work_keys_str_mv AT hupan evaluationofhydrophobicallyassociatingcationicstarchbasedflocculantsinsludgedewatering
AT shenshaohang evaluationofhydrophobicallyassociatingcationicstarchbasedflocculantsinsludgedewatering
AT yanghu evaluationofhydrophobicallyassociatingcationicstarchbasedflocculantsinsludgedewatering