Cargando…

ACURATE neo™ aortic valve implantation via carotid artery access: first case report

BACKGROUND: The ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) is predominantly implanted via femoral access. Transcarotid use of this prothesis has never been reported. CASE PRESENTATION: We present the case of an 89-year-old woman referred to us for a transc...

Descripción completa

Detalles Bibliográficos
Autores principales: Aludaat, Chadi, Canville, Alexandre, Landolff, Quentin, Godin, Matthieu, Bauer, Fabrice, Doguet, Fabien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8176695/
https://www.ncbi.nlm.nih.gov/pubmed/34088318
http://dx.doi.org/10.1186/s13019-021-01544-5
_version_ 1783703298811887616
author Aludaat, Chadi
Canville, Alexandre
Landolff, Quentin
Godin, Matthieu
Bauer, Fabrice
Doguet, Fabien
author_facet Aludaat, Chadi
Canville, Alexandre
Landolff, Quentin
Godin, Matthieu
Bauer, Fabrice
Doguet, Fabien
author_sort Aludaat, Chadi
collection PubMed
description BACKGROUND: The ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) is predominantly implanted via femoral access. Transcarotid use of this prothesis has never been reported. CASE PRESENTATION: We present the case of an 89-year-old woman referred to us for a transcatheter aortic valve replacement (TAVR). After apparatus imaging of the aortic annulus and the peripheral vascular pathway, the heart team was confronted with a triple challenge: (i) The preferable choice of a self-expanding valve because of a small aortic annulus in an obese woman. (ii) Gaining favorable access to the coronary ostia, considering multiple recent coronary stenting. (iii) Utilizing an alternative arterial access because of iliac and femoral severely calcified stenosis. Implanting the ACURATE neo™ transcatheter heart valve (THV) via carotidal access allowed us to overcome these challenges. The procedure was performed successfully without any short-term complications. CONCLUSION: We report the first case of implantation of an ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) via the right common carotid artery.
format Online
Article
Text
id pubmed-8176695
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-81766952021-06-04 ACURATE neo™ aortic valve implantation via carotid artery access: first case report Aludaat, Chadi Canville, Alexandre Landolff, Quentin Godin, Matthieu Bauer, Fabrice Doguet, Fabien J Cardiothorac Surg Case Report BACKGROUND: The ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) is predominantly implanted via femoral access. Transcarotid use of this prothesis has never been reported. CASE PRESENTATION: We present the case of an 89-year-old woman referred to us for a transcatheter aortic valve replacement (TAVR). After apparatus imaging of the aortic annulus and the peripheral vascular pathway, the heart team was confronted with a triple challenge: (i) The preferable choice of a self-expanding valve because of a small aortic annulus in an obese woman. (ii) Gaining favorable access to the coronary ostia, considering multiple recent coronary stenting. (iii) Utilizing an alternative arterial access because of iliac and femoral severely calcified stenosis. Implanting the ACURATE neo™ transcatheter heart valve (THV) via carotidal access allowed us to overcome these challenges. The procedure was performed successfully without any short-term complications. CONCLUSION: We report the first case of implantation of an ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) via the right common carotid artery. BioMed Central 2021-06-04 /pmc/articles/PMC8176695/ /pubmed/34088318 http://dx.doi.org/10.1186/s13019-021-01544-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Case Report
Aludaat, Chadi
Canville, Alexandre
Landolff, Quentin
Godin, Matthieu
Bauer, Fabrice
Doguet, Fabien
ACURATE neo™ aortic valve implantation via carotid artery access: first case report
title ACURATE neo™ aortic valve implantation via carotid artery access: first case report
title_full ACURATE neo™ aortic valve implantation via carotid artery access: first case report
title_fullStr ACURATE neo™ aortic valve implantation via carotid artery access: first case report
title_full_unstemmed ACURATE neo™ aortic valve implantation via carotid artery access: first case report
title_short ACURATE neo™ aortic valve implantation via carotid artery access: first case report
title_sort acurate neo™ aortic valve implantation via carotid artery access: first case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8176695/
https://www.ncbi.nlm.nih.gov/pubmed/34088318
http://dx.doi.org/10.1186/s13019-021-01544-5
work_keys_str_mv AT aludaatchadi acurateneoaorticvalveimplantationviacarotidarteryaccessfirstcasereport
AT canvillealexandre acurateneoaorticvalveimplantationviacarotidarteryaccessfirstcasereport
AT landolffquentin acurateneoaorticvalveimplantationviacarotidarteryaccessfirstcasereport
AT godinmatthieu acurateneoaorticvalveimplantationviacarotidarteryaccessfirstcasereport
AT bauerfabrice acurateneoaorticvalveimplantationviacarotidarteryaccessfirstcasereport
AT doguetfabien acurateneoaorticvalveimplantationviacarotidarteryaccessfirstcasereport