CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera

Routine blood pressure (BP) measurement in pregnancy is commonly performed using automated oscillometric devices. Since no wireless oscillometric BP device has been validated in preeclamptic populations, a simple approach for capturing readings from such devices is needed, especially in low-resource...

Descripción completa

Detalles Bibliográficos
Autores principales: Kulkarni, Samruddhi S., Katebi, Nasim, Valderrama, Camilo E., Rohloff, Peter, Clifford, Gari D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8177819/
https://www.ncbi.nlm.nih.gov/pubmed/34095816
http://dx.doi.org/10.3389/frai.2021.543176
_version_ 1783703455790006272
author Kulkarni, Samruddhi S.
Katebi, Nasim
Valderrama, Camilo E.
Rohloff, Peter
Clifford, Gari D.
author_facet Kulkarni, Samruddhi S.
Katebi, Nasim
Valderrama, Camilo E.
Rohloff, Peter
Clifford, Gari D.
author_sort Kulkarni, Samruddhi S.
collection PubMed
description Routine blood pressure (BP) measurement in pregnancy is commonly performed using automated oscillometric devices. Since no wireless oscillometric BP device has been validated in preeclamptic populations, a simple approach for capturing readings from such devices is needed, especially in low-resource settings where transmission of BP data from the field to central locations is an important mechanism for triage. To this end, a total of 8192 BP readings were captured from the Liquid Crystal Display (LCD) screen of a standard Omron M7 self-inflating BP cuff using a cellphone camera. A cohort of 49 lay midwives captured these data from 1697 pregnant women carrying singletons between 6 weeks and 40 weeks gestational age in rural Guatemala during routine screening. Images exhibited a wide variability in their appearance due to variations in orientation and parallax; environmental factors such as lighting, shadows; and image acquisition factors such as motion blur and problems with focus. Images were independently labeled for readability and quality by three annotators (BP range: 34–203 mm Hg) and disagreements were resolved. Methods to preprocess and automatically segment the LCD images into diastolic BP, systolic BP and heart rate using a contour-based technique were developed. A deep convolutional neural network was then trained to convert the LCD images into numerical values using a multi-digit recognition approach. On readable low- and high-quality images, this proposed approach achieved a 91% classification accuracy and mean absolute error of 3.19 mm Hg for systolic BP and 91% accuracy and mean absolute error of 0.94 mm Hg for diastolic BP. These error values are within the FDA guidelines for BP monitoring when poor quality images are excluded. The performance of the proposed approach was shown to be greatly superior to state-of-the-art open-source tools (Tesseract and the Google Vision API). The algorithm was developed such that it could be deployed on a phone and work without connectivity to a network.
format Online
Article
Text
id pubmed-8177819
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-81778192021-06-05 CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera Kulkarni, Samruddhi S. Katebi, Nasim Valderrama, Camilo E. Rohloff, Peter Clifford, Gari D. Front Artif Intell Artificial Intelligence Routine blood pressure (BP) measurement in pregnancy is commonly performed using automated oscillometric devices. Since no wireless oscillometric BP device has been validated in preeclamptic populations, a simple approach for capturing readings from such devices is needed, especially in low-resource settings where transmission of BP data from the field to central locations is an important mechanism for triage. To this end, a total of 8192 BP readings were captured from the Liquid Crystal Display (LCD) screen of a standard Omron M7 self-inflating BP cuff using a cellphone camera. A cohort of 49 lay midwives captured these data from 1697 pregnant women carrying singletons between 6 weeks and 40 weeks gestational age in rural Guatemala during routine screening. Images exhibited a wide variability in their appearance due to variations in orientation and parallax; environmental factors such as lighting, shadows; and image acquisition factors such as motion blur and problems with focus. Images were independently labeled for readability and quality by three annotators (BP range: 34–203 mm Hg) and disagreements were resolved. Methods to preprocess and automatically segment the LCD images into diastolic BP, systolic BP and heart rate using a contour-based technique were developed. A deep convolutional neural network was then trained to convert the LCD images into numerical values using a multi-digit recognition approach. On readable low- and high-quality images, this proposed approach achieved a 91% classification accuracy and mean absolute error of 3.19 mm Hg for systolic BP and 91% accuracy and mean absolute error of 0.94 mm Hg for diastolic BP. These error values are within the FDA guidelines for BP monitoring when poor quality images are excluded. The performance of the proposed approach was shown to be greatly superior to state-of-the-art open-source tools (Tesseract and the Google Vision API). The algorithm was developed such that it could be deployed on a phone and work without connectivity to a network. Frontiers Media S.A. 2021-05-21 /pmc/articles/PMC8177819/ /pubmed/34095816 http://dx.doi.org/10.3389/frai.2021.543176 Text en Copyright © 2021 Kulkarni, Katebi, Valderrama, Rohloff and Clifford. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Artificial Intelligence
Kulkarni, Samruddhi S.
Katebi, Nasim
Valderrama, Camilo E.
Rohloff, Peter
Clifford, Gari D.
CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera
title CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera
title_full CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera
title_fullStr CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera
title_full_unstemmed CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera
title_short CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera
title_sort cnn-based lcd transcription of blood pressure from a mobile phone camera
topic Artificial Intelligence
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8177819/
https://www.ncbi.nlm.nih.gov/pubmed/34095816
http://dx.doi.org/10.3389/frai.2021.543176
work_keys_str_mv AT kulkarnisamruddhis cnnbasedlcdtranscriptionofbloodpressurefromamobilephonecamera
AT katebinasim cnnbasedlcdtranscriptionofbloodpressurefromamobilephonecamera
AT valderramacamiloe cnnbasedlcdtranscriptionofbloodpressurefromamobilephonecamera
AT rohloffpeter cnnbasedlcdtranscriptionofbloodpressurefromamobilephonecamera
AT cliffordgarid cnnbasedlcdtranscriptionofbloodpressurefromamobilephonecamera