Cargando…

New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique

BACKGROUND: The purpose of this study was to identify nerves at risk when using a minimally invasive plate osteosynthesis precontoured long proximal humerus locking plate and to evaluate the risk of injury to deltoid insertion and brachialis muscle. METHODS: Ten cadaveric upper limb specimens were u...

Descripción completa

Detalles Bibliográficos
Autores principales: Ekdahl, Max, Dominguez, Cristián, Pinedo, Miguel, López, Sebastián, Gutiérrez, Vicente
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8178608/
https://www.ncbi.nlm.nih.gov/pubmed/34136867
http://dx.doi.org/10.1016/j.jseint.2020.12.010
_version_ 1783703606593060864
author Ekdahl, Max
Dominguez, Cristián
Pinedo, Miguel
López, Sebastián
Gutiérrez, Vicente
author_facet Ekdahl, Max
Dominguez, Cristián
Pinedo, Miguel
López, Sebastián
Gutiérrez, Vicente
author_sort Ekdahl, Max
collection PubMed
description BACKGROUND: The purpose of this study was to identify nerves at risk when using a minimally invasive plate osteosynthesis precontoured long proximal humerus locking plate and to evaluate the risk of injury to deltoid insertion and brachialis muscle. METHODS: Ten cadaveric upper limb specimens were used. A transdeltoid anterolateral approach was performed proximally and a second anterior approach was performed distally. A 14-hole “low” long precountored ALPS locking plate (Biomet Trauma; Zimmer Biomet, Warsaw, IN, USA) was used. Subsequently, anatomic dissection to measure the anatomic relationship of the plate with the deltoid insertion, with the brachialis muscle, and with the axillary, radial, and musculocutaneous nerves was performed. RESULTS: The mean humeral length was 302 mm (standard deviation 52.3, 99% confidence interval: 259.3-344.6). In 6 specimens, the axillary nerve was located at the level of the third row of holes of the plate; in 3 specimens, at the level of the fourth row; and in one specimen, at the level of the second row. The distance between the plate and the musculocutaneous nerve was on average 10.2 mm (standard deviation 4, 99% confidence interval: 6.9-13.5) and between the plate and the radial nerve was on average 7.9 mm (standard deviation 4.7, 99% confidence interval: 4-11.8). The plate pierced the anterior distal fibers of the deltoid in all specimens. In 8 specimens, no brachialis muscle fibers were located under the plate. CONCLUSIONS: The use of the long precontoured 14-hole ALPS locking plate with the minimally invasive plate osteosynthesis technique, previously identifying the axillary and musculocutaneous nerves, is feasible; however, the distances between the plate and the nerves remain low, so caution should be maintained. Despite the curved design of the plate, the deltoid insertion is partially compromised in all cases.
format Online
Article
Text
id pubmed-8178608
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-81786082021-06-15 New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique Ekdahl, Max Dominguez, Cristián Pinedo, Miguel López, Sebastián Gutiérrez, Vicente JSES Int Shoulder BACKGROUND: The purpose of this study was to identify nerves at risk when using a minimally invasive plate osteosynthesis precontoured long proximal humerus locking plate and to evaluate the risk of injury to deltoid insertion and brachialis muscle. METHODS: Ten cadaveric upper limb specimens were used. A transdeltoid anterolateral approach was performed proximally and a second anterior approach was performed distally. A 14-hole “low” long precountored ALPS locking plate (Biomet Trauma; Zimmer Biomet, Warsaw, IN, USA) was used. Subsequently, anatomic dissection to measure the anatomic relationship of the plate with the deltoid insertion, with the brachialis muscle, and with the axillary, radial, and musculocutaneous nerves was performed. RESULTS: The mean humeral length was 302 mm (standard deviation 52.3, 99% confidence interval: 259.3-344.6). In 6 specimens, the axillary nerve was located at the level of the third row of holes of the plate; in 3 specimens, at the level of the fourth row; and in one specimen, at the level of the second row. The distance between the plate and the musculocutaneous nerve was on average 10.2 mm (standard deviation 4, 99% confidence interval: 6.9-13.5) and between the plate and the radial nerve was on average 7.9 mm (standard deviation 4.7, 99% confidence interval: 4-11.8). The plate pierced the anterior distal fibers of the deltoid in all specimens. In 8 specimens, no brachialis muscle fibers were located under the plate. CONCLUSIONS: The use of the long precontoured 14-hole ALPS locking plate with the minimally invasive plate osteosynthesis technique, previously identifying the axillary and musculocutaneous nerves, is feasible; however, the distances between the plate and the nerves remain low, so caution should be maintained. Despite the curved design of the plate, the deltoid insertion is partially compromised in all cases. Elsevier 2021-02-24 /pmc/articles/PMC8178608/ /pubmed/34136867 http://dx.doi.org/10.1016/j.jseint.2020.12.010 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Shoulder
Ekdahl, Max
Dominguez, Cristián
Pinedo, Miguel
López, Sebastián
Gutiérrez, Vicente
New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique
title New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique
title_full New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique
title_fullStr New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique
title_full_unstemmed New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique
title_short New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique
title_sort new precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique
topic Shoulder
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8178608/
https://www.ncbi.nlm.nih.gov/pubmed/34136867
http://dx.doi.org/10.1016/j.jseint.2020.12.010
work_keys_str_mv AT ekdahlmax newprecontouredlonglockingplateforproximalmetadiaphysealfracturesofthehumerusacadavericstudyforitsusewiththeminimallyinvasivetechnique
AT dominguezcristian newprecontouredlonglockingplateforproximalmetadiaphysealfracturesofthehumerusacadavericstudyforitsusewiththeminimallyinvasivetechnique
AT pinedomiguel newprecontouredlonglockingplateforproximalmetadiaphysealfracturesofthehumerusacadavericstudyforitsusewiththeminimallyinvasivetechnique
AT lopezsebastian newprecontouredlonglockingplateforproximalmetadiaphysealfracturesofthehumerusacadavericstudyforitsusewiththeminimallyinvasivetechnique
AT gutierrezvicente newprecontouredlonglockingplateforproximalmetadiaphysealfracturesofthehumerusacadavericstudyforitsusewiththeminimallyinvasivetechnique