Cargando…

Arterial Healing 10 Months After Implantation of an Ultrathin-Strut, Biodegradable-Polymer, Sirolimus-Eluting Stent ― An Angioscopic Study ―

Background: The Orsiro(TM) ultrathin-strut, biodegradable-polymer, sirolimus-eluting stent (O-SES) has specific characteristics regarding its components and has demonstrated comparable clinical outcomes compared with durable-polymer, drug-eluting stents (DES). However, arterial repair following depl...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsujimura, Takuya, Ishihara, Takayuki, Iida, Osamu, Hata, Yosuke, Toyoshima, Taku, Higashino, Naoko, Kurata, Naoya, Asai, Mitsutoshi, Masuda, Masaharu, Okamoto, Shin, Nanto, Kiyonori, Kanda, Takashi, Matsuda, Yasuhiro, Mano, Toshiaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Circulation Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8180372/
https://www.ncbi.nlm.nih.gov/pubmed/34136706
http://dx.doi.org/10.1253/circrep.CR-21-0053
Descripción
Sumario:Background: The Orsiro(TM) ultrathin-strut, biodegradable-polymer, sirolimus-eluting stent (O-SES) has specific characteristics regarding its components and has demonstrated comparable clinical outcomes compared with durable-polymer, drug-eluting stents (DES). However, arterial repair following deployment of the O-SES has not been elucidated to date. Methods and Results: Using data from the Kansai Rosai Hospital database between November 2010 and September 2020, we analyzed coronary angioscopy (CAS) findings a mean (±SD) of 10±2 months after implantation of an O-SES, a durable-polymer everolimus-eluting stent (Xience(TM); X-EES), or a biodegradable-polymer everolimus-eluting stent (Synergy(TM); S-EES). Neointimal coverage (NIC), yellow color intensity of the stented segment, and the incidence of thrombus adhesion were compared between the O-SES (66 stents from 42 patients), X-EES (119 stents from 87 patients), and S-EES (132 stents from 88 patients). NIC was significantly thinner for the O-SES than S-EES (P<0.001), but was similar between the O-SES and X-EES (P=0.25). Yellow color intensity was significantly greater for the O-SES than X-EES (P<0.001), but similar between the O-SES and S-EES (P=0.51). The incidence of thrombus adhesions was similar in all 3 groups. Conclusions: O-SES and X-EES resulted in similar inhibition of NIC and both resulted in a thinner NIC than with S-EES. In addition, O-SES exhibited a similar degree of thrombus adhesion as the other DES, suggesting similar thrombogenicity.