Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience

Background: Ischemia injury affects the recovery of liver allograft function. We propose a novel technique aimed at avoiding a second ischemic injury: transplanting an extended criteria donor (ECD) liver directly under normothermic machine perfusion (NMP) without recooling. We studied two cases to e...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Zhitao, Hong, Xitao, Huang, Shanzhou, Wang, Tielong, Ma, Yihao, Guo, Yiwen, Huang, Changjun, Zhao, Qiang, Guo, Zhiyong, He, Xiaoshun, Ju, Weiqiang, Chen, Maogen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8180843/
https://www.ncbi.nlm.nih.gov/pubmed/34109206
http://dx.doi.org/10.3389/fsurg.2021.638090
_version_ 1783704036204085248
author Chen, Zhitao
Hong, Xitao
Huang, Shanzhou
Wang, Tielong
Ma, Yihao
Guo, Yiwen
Huang, Changjun
Zhao, Qiang
Guo, Zhiyong
He, Xiaoshun
Ju, Weiqiang
Chen, Maogen
author_facet Chen, Zhitao
Hong, Xitao
Huang, Shanzhou
Wang, Tielong
Ma, Yihao
Guo, Yiwen
Huang, Changjun
Zhao, Qiang
Guo, Zhiyong
He, Xiaoshun
Ju, Weiqiang
Chen, Maogen
author_sort Chen, Zhitao
collection PubMed
description Background: Ischemia injury affects the recovery of liver allograft function. We propose a novel technique aimed at avoiding a second ischemic injury: transplanting an extended criteria donor (ECD) liver directly under normothermic machine perfusion (NMP) without recooling. We studied two cases to evaluate the efficacy and safety of this technique. Methods: The perioperative characteristics and postoperative outcomes of two recipients of ECD livers were analyzed. Both transplantations were performed with continuous normothermic machine perfusion without recooling. Result: In case 1, the cause of donor death was anoxia, and the donor liver had hypernatremia before procurement. The recipient was diagnosed with decompensated cirrhosis. His model for end-stage liver disease (MELD) score was 38. In case 2, the donor liver was from a donor after cardiac death (DCD), and the donor had elevated aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels. The recipient was diagnosed with acute hepatic failure. His MELD score was 35. Both donor livers were maintained under NMP and then transplanted without recooling. The peak ALT and AST levels after surgery were 452 and 770 U/L in case 1 and 100 and 592 U/L in case 2. Neither early allograft dysfunction (EAD) nor primary graft non-function (PNF) was present in these two cases. Conclusion: In conclusion, our results demonstrate that continuous NMP without recooling is efficacious and safe for LT with extended criteria donor livers. Further investigations of this technique will be performed to confirm these promising results.
format Online
Article
Text
id pubmed-8180843
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-81808432021-06-08 Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience Chen, Zhitao Hong, Xitao Huang, Shanzhou Wang, Tielong Ma, Yihao Guo, Yiwen Huang, Changjun Zhao, Qiang Guo, Zhiyong He, Xiaoshun Ju, Weiqiang Chen, Maogen Front Surg Surgery Background: Ischemia injury affects the recovery of liver allograft function. We propose a novel technique aimed at avoiding a second ischemic injury: transplanting an extended criteria donor (ECD) liver directly under normothermic machine perfusion (NMP) without recooling. We studied two cases to evaluate the efficacy and safety of this technique. Methods: The perioperative characteristics and postoperative outcomes of two recipients of ECD livers were analyzed. Both transplantations were performed with continuous normothermic machine perfusion without recooling. Result: In case 1, the cause of donor death was anoxia, and the donor liver had hypernatremia before procurement. The recipient was diagnosed with decompensated cirrhosis. His model for end-stage liver disease (MELD) score was 38. In case 2, the donor liver was from a donor after cardiac death (DCD), and the donor had elevated aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels. The recipient was diagnosed with acute hepatic failure. His MELD score was 35. Both donor livers were maintained under NMP and then transplanted without recooling. The peak ALT and AST levels after surgery were 452 and 770 U/L in case 1 and 100 and 592 U/L in case 2. Neither early allograft dysfunction (EAD) nor primary graft non-function (PNF) was present in these two cases. Conclusion: In conclusion, our results demonstrate that continuous NMP without recooling is efficacious and safe for LT with extended criteria donor livers. Further investigations of this technique will be performed to confirm these promising results. Frontiers Media S.A. 2021-05-24 /pmc/articles/PMC8180843/ /pubmed/34109206 http://dx.doi.org/10.3389/fsurg.2021.638090 Text en Copyright © 2021 Chen, Hong, Huang, Wang, Ma, Guo, Huang, Zhao, Guo, He, Ju and Chen. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Chen, Zhitao
Hong, Xitao
Huang, Shanzhou
Wang, Tielong
Ma, Yihao
Guo, Yiwen
Huang, Changjun
Zhao, Qiang
Guo, Zhiyong
He, Xiaoshun
Ju, Weiqiang
Chen, Maogen
Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience
title Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience
title_full Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience
title_fullStr Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience
title_full_unstemmed Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience
title_short Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience
title_sort continuous normothermic machine perfusion for renovation of extended criteria donor livers without recooling in liver transplantation: a pilot experience
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8180843/
https://www.ncbi.nlm.nih.gov/pubmed/34109206
http://dx.doi.org/10.3389/fsurg.2021.638090
work_keys_str_mv AT chenzhitao continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT hongxitao continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT huangshanzhou continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT wangtielong continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT mayihao continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT guoyiwen continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT huangchangjun continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT zhaoqiang continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT guozhiyong continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT hexiaoshun continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT juweiqiang continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience
AT chenmaogen continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience