Cargando…
Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience
Background: Ischemia injury affects the recovery of liver allograft function. We propose a novel technique aimed at avoiding a second ischemic injury: transplanting an extended criteria donor (ECD) liver directly under normothermic machine perfusion (NMP) without recooling. We studied two cases to e...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8180843/ https://www.ncbi.nlm.nih.gov/pubmed/34109206 http://dx.doi.org/10.3389/fsurg.2021.638090 |
_version_ | 1783704036204085248 |
---|---|
author | Chen, Zhitao Hong, Xitao Huang, Shanzhou Wang, Tielong Ma, Yihao Guo, Yiwen Huang, Changjun Zhao, Qiang Guo, Zhiyong He, Xiaoshun Ju, Weiqiang Chen, Maogen |
author_facet | Chen, Zhitao Hong, Xitao Huang, Shanzhou Wang, Tielong Ma, Yihao Guo, Yiwen Huang, Changjun Zhao, Qiang Guo, Zhiyong He, Xiaoshun Ju, Weiqiang Chen, Maogen |
author_sort | Chen, Zhitao |
collection | PubMed |
description | Background: Ischemia injury affects the recovery of liver allograft function. We propose a novel technique aimed at avoiding a second ischemic injury: transplanting an extended criteria donor (ECD) liver directly under normothermic machine perfusion (NMP) without recooling. We studied two cases to evaluate the efficacy and safety of this technique. Methods: The perioperative characteristics and postoperative outcomes of two recipients of ECD livers were analyzed. Both transplantations were performed with continuous normothermic machine perfusion without recooling. Result: In case 1, the cause of donor death was anoxia, and the donor liver had hypernatremia before procurement. The recipient was diagnosed with decompensated cirrhosis. His model for end-stage liver disease (MELD) score was 38. In case 2, the donor liver was from a donor after cardiac death (DCD), and the donor had elevated aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels. The recipient was diagnosed with acute hepatic failure. His MELD score was 35. Both donor livers were maintained under NMP and then transplanted without recooling. The peak ALT and AST levels after surgery were 452 and 770 U/L in case 1 and 100 and 592 U/L in case 2. Neither early allograft dysfunction (EAD) nor primary graft non-function (PNF) was present in these two cases. Conclusion: In conclusion, our results demonstrate that continuous NMP without recooling is efficacious and safe for LT with extended criteria donor livers. Further investigations of this technique will be performed to confirm these promising results. |
format | Online Article Text |
id | pubmed-8180843 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-81808432021-06-08 Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience Chen, Zhitao Hong, Xitao Huang, Shanzhou Wang, Tielong Ma, Yihao Guo, Yiwen Huang, Changjun Zhao, Qiang Guo, Zhiyong He, Xiaoshun Ju, Weiqiang Chen, Maogen Front Surg Surgery Background: Ischemia injury affects the recovery of liver allograft function. We propose a novel technique aimed at avoiding a second ischemic injury: transplanting an extended criteria donor (ECD) liver directly under normothermic machine perfusion (NMP) without recooling. We studied two cases to evaluate the efficacy and safety of this technique. Methods: The perioperative characteristics and postoperative outcomes of two recipients of ECD livers were analyzed. Both transplantations were performed with continuous normothermic machine perfusion without recooling. Result: In case 1, the cause of donor death was anoxia, and the donor liver had hypernatremia before procurement. The recipient was diagnosed with decompensated cirrhosis. His model for end-stage liver disease (MELD) score was 38. In case 2, the donor liver was from a donor after cardiac death (DCD), and the donor had elevated aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels. The recipient was diagnosed with acute hepatic failure. His MELD score was 35. Both donor livers were maintained under NMP and then transplanted without recooling. The peak ALT and AST levels after surgery were 452 and 770 U/L in case 1 and 100 and 592 U/L in case 2. Neither early allograft dysfunction (EAD) nor primary graft non-function (PNF) was present in these two cases. Conclusion: In conclusion, our results demonstrate that continuous NMP without recooling is efficacious and safe for LT with extended criteria donor livers. Further investigations of this technique will be performed to confirm these promising results. Frontiers Media S.A. 2021-05-24 /pmc/articles/PMC8180843/ /pubmed/34109206 http://dx.doi.org/10.3389/fsurg.2021.638090 Text en Copyright © 2021 Chen, Hong, Huang, Wang, Ma, Guo, Huang, Zhao, Guo, He, Ju and Chen. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Chen, Zhitao Hong, Xitao Huang, Shanzhou Wang, Tielong Ma, Yihao Guo, Yiwen Huang, Changjun Zhao, Qiang Guo, Zhiyong He, Xiaoshun Ju, Weiqiang Chen, Maogen Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience |
title | Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience |
title_full | Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience |
title_fullStr | Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience |
title_full_unstemmed | Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience |
title_short | Continuous Normothermic Machine Perfusion for Renovation of Extended Criteria Donor Livers Without Recooling in Liver Transplantation: A Pilot Experience |
title_sort | continuous normothermic machine perfusion for renovation of extended criteria donor livers without recooling in liver transplantation: a pilot experience |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8180843/ https://www.ncbi.nlm.nih.gov/pubmed/34109206 http://dx.doi.org/10.3389/fsurg.2021.638090 |
work_keys_str_mv | AT chenzhitao continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT hongxitao continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT huangshanzhou continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT wangtielong continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT mayihao continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT guoyiwen continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT huangchangjun continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT zhaoqiang continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT guozhiyong continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT hexiaoshun continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT juweiqiang continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience AT chenmaogen continuousnormothermicmachineperfusionforrenovationofextendedcriteriadonorliverswithoutrecoolinginlivertransplantationapilotexperience |