CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution
BACKGROUND: Rate-varying S1S2 stimulation protocols can be used for restitution studies to characterize atrial substrate, ionic remodeling, and atrial fibrillation risk. Clinical restitution studies with numerous patients create large amounts of these data. Thus, an automated pipeline to evaluate cl...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8181407/ https://www.ncbi.nlm.nih.gov/pubmed/34108887 http://dx.doi.org/10.3389/fphys.2021.673047 |
_version_ | 1783704089436094464 |
---|---|
author | Nothstein, Mark Luik, Armin Jadidi, Amir Sánchez, Jorge Unger, Laura A. Wülfers, Eike M. Dössel, Olaf Seemann, Gunnar Schmitt, Claus Loewe, Axel |
author_facet | Nothstein, Mark Luik, Armin Jadidi, Amir Sánchez, Jorge Unger, Laura A. Wülfers, Eike M. Dössel, Olaf Seemann, Gunnar Schmitt, Claus Loewe, Axel |
author_sort | Nothstein, Mark |
collection | PubMed |
description | BACKGROUND: Rate-varying S1S2 stimulation protocols can be used for restitution studies to characterize atrial substrate, ionic remodeling, and atrial fibrillation risk. Clinical restitution studies with numerous patients create large amounts of these data. Thus, an automated pipeline to evaluate clinically acquired S1S2 stimulation protocol data necessitates consistent, robust, reproducible, and precise evaluation of local activation times, electrogram amplitude, and conduction velocity. Here, we present the CVAR-Seg pipeline, developed focusing on three challenges: (i) No previous knowledge of the stimulation parameters is available, thus, arbitrary protocols are supported. (ii) The pipeline remains robust under different noise conditions. (iii) The pipeline supports segmentation of atrial activities in close temporal proximity to the stimulation artifact, which is challenging due to larger amplitude and slope of the stimulus compared to the atrial activity. METHODS AND RESULTS: The S1 basic cycle length was estimated by time interval detection. Stimulation time windows were segmented by detecting synchronous peaks in different channels surpassing an amplitude threshold and identifying time intervals between detected stimuli. Elimination of the stimulation artifact by a matched filter allowed detection of local activation times in temporal proximity. A non-linear signal energy operator was used to segment periods of atrial activity. Geodesic and Euclidean inter electrode distances allowed approximation of conduction velocity. The automatic segmentation performance of the CVAR-Seg pipeline was evaluated on 37 synthetic datasets with decreasing signal-to-noise ratios. Noise was modeled by reconstructing the frequency spectrum of clinical noise. The pipeline retained a median local activation time error below a single sample (1 ms) for signal-to-noise ratios as low as 0 dB representing a high clinical noise level. As a proof of concept, the pipeline was tested on a CARTO case of a paroxysmal atrial fibrillation patient and yielded plausible restitution curves for conduction speed and amplitude. CONCLUSION: The proposed openly available CVAR-Seg pipeline promises fast, fully automated, robust, and accurate evaluations of atrial signals even with low signal-to-noise ratios. This is achieved by solving the proximity problem of stimulation and atrial activity to enable standardized evaluation without introducing human bias for large data sets. |
format | Online Article Text |
id | pubmed-8181407 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-81814072021-06-08 CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution Nothstein, Mark Luik, Armin Jadidi, Amir Sánchez, Jorge Unger, Laura A. Wülfers, Eike M. Dössel, Olaf Seemann, Gunnar Schmitt, Claus Loewe, Axel Front Physiol Physiology BACKGROUND: Rate-varying S1S2 stimulation protocols can be used for restitution studies to characterize atrial substrate, ionic remodeling, and atrial fibrillation risk. Clinical restitution studies with numerous patients create large amounts of these data. Thus, an automated pipeline to evaluate clinically acquired S1S2 stimulation protocol data necessitates consistent, robust, reproducible, and precise evaluation of local activation times, electrogram amplitude, and conduction velocity. Here, we present the CVAR-Seg pipeline, developed focusing on three challenges: (i) No previous knowledge of the stimulation parameters is available, thus, arbitrary protocols are supported. (ii) The pipeline remains robust under different noise conditions. (iii) The pipeline supports segmentation of atrial activities in close temporal proximity to the stimulation artifact, which is challenging due to larger amplitude and slope of the stimulus compared to the atrial activity. METHODS AND RESULTS: The S1 basic cycle length was estimated by time interval detection. Stimulation time windows were segmented by detecting synchronous peaks in different channels surpassing an amplitude threshold and identifying time intervals between detected stimuli. Elimination of the stimulation artifact by a matched filter allowed detection of local activation times in temporal proximity. A non-linear signal energy operator was used to segment periods of atrial activity. Geodesic and Euclidean inter electrode distances allowed approximation of conduction velocity. The automatic segmentation performance of the CVAR-Seg pipeline was evaluated on 37 synthetic datasets with decreasing signal-to-noise ratios. Noise was modeled by reconstructing the frequency spectrum of clinical noise. The pipeline retained a median local activation time error below a single sample (1 ms) for signal-to-noise ratios as low as 0 dB representing a high clinical noise level. As a proof of concept, the pipeline was tested on a CARTO case of a paroxysmal atrial fibrillation patient and yielded plausible restitution curves for conduction speed and amplitude. CONCLUSION: The proposed openly available CVAR-Seg pipeline promises fast, fully automated, robust, and accurate evaluations of atrial signals even with low signal-to-noise ratios. This is achieved by solving the proximity problem of stimulation and atrial activity to enable standardized evaluation without introducing human bias for large data sets. Frontiers Media S.A. 2021-05-24 /pmc/articles/PMC8181407/ /pubmed/34108887 http://dx.doi.org/10.3389/fphys.2021.673047 Text en Copyright © 2021 Nothstein, Luik, Jadidi, Sánchez, Unger, Wülfers, Dössel, Seemann, Schmitt and Loewe. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Nothstein, Mark Luik, Armin Jadidi, Amir Sánchez, Jorge Unger, Laura A. Wülfers, Eike M. Dössel, Olaf Seemann, Gunnar Schmitt, Claus Loewe, Axel CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution |
title | CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution |
title_full | CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution |
title_fullStr | CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution |
title_full_unstemmed | CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution |
title_short | CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution |
title_sort | cvar-seg: an automated signal segmentation pipeline for conduction velocity and amplitude restitution |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8181407/ https://www.ncbi.nlm.nih.gov/pubmed/34108887 http://dx.doi.org/10.3389/fphys.2021.673047 |
work_keys_str_mv | AT nothsteinmark cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT luikarmin cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT jadidiamir cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT sanchezjorge cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT ungerlauraa cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT wulferseikem cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT dosselolaf cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT seemanngunnar cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT schmittclaus cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution AT loeweaxel cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution |