CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution

BACKGROUND: Rate-varying S1S2 stimulation protocols can be used for restitution studies to characterize atrial substrate, ionic remodeling, and atrial fibrillation risk. Clinical restitution studies with numerous patients create large amounts of these data. Thus, an automated pipeline to evaluate cl...

Descripción completa

Detalles Bibliográficos
Autores principales: Nothstein, Mark, Luik, Armin, Jadidi, Amir, Sánchez, Jorge, Unger, Laura A., Wülfers, Eike M., Dössel, Olaf, Seemann, Gunnar, Schmitt, Claus, Loewe, Axel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8181407/
https://www.ncbi.nlm.nih.gov/pubmed/34108887
http://dx.doi.org/10.3389/fphys.2021.673047
_version_ 1783704089436094464
author Nothstein, Mark
Luik, Armin
Jadidi, Amir
Sánchez, Jorge
Unger, Laura A.
Wülfers, Eike M.
Dössel, Olaf
Seemann, Gunnar
Schmitt, Claus
Loewe, Axel
author_facet Nothstein, Mark
Luik, Armin
Jadidi, Amir
Sánchez, Jorge
Unger, Laura A.
Wülfers, Eike M.
Dössel, Olaf
Seemann, Gunnar
Schmitt, Claus
Loewe, Axel
author_sort Nothstein, Mark
collection PubMed
description BACKGROUND: Rate-varying S1S2 stimulation protocols can be used for restitution studies to characterize atrial substrate, ionic remodeling, and atrial fibrillation risk. Clinical restitution studies with numerous patients create large amounts of these data. Thus, an automated pipeline to evaluate clinically acquired S1S2 stimulation protocol data necessitates consistent, robust, reproducible, and precise evaluation of local activation times, electrogram amplitude, and conduction velocity. Here, we present the CVAR-Seg pipeline, developed focusing on three challenges: (i) No previous knowledge of the stimulation parameters is available, thus, arbitrary protocols are supported. (ii) The pipeline remains robust under different noise conditions. (iii) The pipeline supports segmentation of atrial activities in close temporal proximity to the stimulation artifact, which is challenging due to larger amplitude and slope of the stimulus compared to the atrial activity. METHODS AND RESULTS: The S1 basic cycle length was estimated by time interval detection. Stimulation time windows were segmented by detecting synchronous peaks in different channels surpassing an amplitude threshold and identifying time intervals between detected stimuli. Elimination of the stimulation artifact by a matched filter allowed detection of local activation times in temporal proximity. A non-linear signal energy operator was used to segment periods of atrial activity. Geodesic and Euclidean inter electrode distances allowed approximation of conduction velocity. The automatic segmentation performance of the CVAR-Seg pipeline was evaluated on 37 synthetic datasets with decreasing signal-to-noise ratios. Noise was modeled by reconstructing the frequency spectrum of clinical noise. The pipeline retained a median local activation time error below a single sample (1 ms) for signal-to-noise ratios as low as 0 dB representing a high clinical noise level. As a proof of concept, the pipeline was tested on a CARTO case of a paroxysmal atrial fibrillation patient and yielded plausible restitution curves for conduction speed and amplitude. CONCLUSION: The proposed openly available CVAR-Seg pipeline promises fast, fully automated, robust, and accurate evaluations of atrial signals even with low signal-to-noise ratios. This is achieved by solving the proximity problem of stimulation and atrial activity to enable standardized evaluation without introducing human bias for large data sets.
format Online
Article
Text
id pubmed-8181407
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-81814072021-06-08 CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution Nothstein, Mark Luik, Armin Jadidi, Amir Sánchez, Jorge Unger, Laura A. Wülfers, Eike M. Dössel, Olaf Seemann, Gunnar Schmitt, Claus Loewe, Axel Front Physiol Physiology BACKGROUND: Rate-varying S1S2 stimulation protocols can be used for restitution studies to characterize atrial substrate, ionic remodeling, and atrial fibrillation risk. Clinical restitution studies with numerous patients create large amounts of these data. Thus, an automated pipeline to evaluate clinically acquired S1S2 stimulation protocol data necessitates consistent, robust, reproducible, and precise evaluation of local activation times, electrogram amplitude, and conduction velocity. Here, we present the CVAR-Seg pipeline, developed focusing on three challenges: (i) No previous knowledge of the stimulation parameters is available, thus, arbitrary protocols are supported. (ii) The pipeline remains robust under different noise conditions. (iii) The pipeline supports segmentation of atrial activities in close temporal proximity to the stimulation artifact, which is challenging due to larger amplitude and slope of the stimulus compared to the atrial activity. METHODS AND RESULTS: The S1 basic cycle length was estimated by time interval detection. Stimulation time windows were segmented by detecting synchronous peaks in different channels surpassing an amplitude threshold and identifying time intervals between detected stimuli. Elimination of the stimulation artifact by a matched filter allowed detection of local activation times in temporal proximity. A non-linear signal energy operator was used to segment periods of atrial activity. Geodesic and Euclidean inter electrode distances allowed approximation of conduction velocity. The automatic segmentation performance of the CVAR-Seg pipeline was evaluated on 37 synthetic datasets with decreasing signal-to-noise ratios. Noise was modeled by reconstructing the frequency spectrum of clinical noise. The pipeline retained a median local activation time error below a single sample (1 ms) for signal-to-noise ratios as low as 0 dB representing a high clinical noise level. As a proof of concept, the pipeline was tested on a CARTO case of a paroxysmal atrial fibrillation patient and yielded plausible restitution curves for conduction speed and amplitude. CONCLUSION: The proposed openly available CVAR-Seg pipeline promises fast, fully automated, robust, and accurate evaluations of atrial signals even with low signal-to-noise ratios. This is achieved by solving the proximity problem of stimulation and atrial activity to enable standardized evaluation without introducing human bias for large data sets. Frontiers Media S.A. 2021-05-24 /pmc/articles/PMC8181407/ /pubmed/34108887 http://dx.doi.org/10.3389/fphys.2021.673047 Text en Copyright © 2021 Nothstein, Luik, Jadidi, Sánchez, Unger, Wülfers, Dössel, Seemann, Schmitt and Loewe. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Nothstein, Mark
Luik, Armin
Jadidi, Amir
Sánchez, Jorge
Unger, Laura A.
Wülfers, Eike M.
Dössel, Olaf
Seemann, Gunnar
Schmitt, Claus
Loewe, Axel
CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution
title CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution
title_full CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution
title_fullStr CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution
title_full_unstemmed CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution
title_short CVAR-Seg: An Automated Signal Segmentation Pipeline for Conduction Velocity and Amplitude Restitution
title_sort cvar-seg: an automated signal segmentation pipeline for conduction velocity and amplitude restitution
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8181407/
https://www.ncbi.nlm.nih.gov/pubmed/34108887
http://dx.doi.org/10.3389/fphys.2021.673047
work_keys_str_mv AT nothsteinmark cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT luikarmin cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT jadidiamir cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT sanchezjorge cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT ungerlauraa cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT wulferseikem cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT dosselolaf cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT seemanngunnar cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT schmittclaus cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution
AT loeweaxel cvarseganautomatedsignalsegmentationpipelineforconductionvelocityandamplituderestitution