Cargando…

Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study

BACKGROUND: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict...

Descripción completa

Detalles Bibliográficos
Autores principales: Lim, Joon-Ryul, Yoon, Tae-Hwan, Lee, Hwan-Mo, Chun, Yong-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Shoulder and Elbow Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8181839/
https://www.ncbi.nlm.nih.gov/pubmed/34078013
http://dx.doi.org/10.5397/cise.2021.00227
_version_ 1783704129201242112
author Lim, Joon-Ryul
Yoon, Tae-Hwan
Lee, Hwan-Mo
Chun, Yong-Min
author_facet Lim, Joon-Ryul
Yoon, Tae-Hwan
Lee, Hwan-Mo
Chun, Yong-Min
author_sort Lim, Joon-Ryul
collection PubMed
description BACKGROUND: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict the occurrence of anatomic fit mismatch. We hypothesized that the smaller the humerus size, the greater the anatomic fit mismatch with EADHP. METHODS: Twenty humeri were analyzed in this study. Humeral length and distal humeral width were used as parameters of humeral size. Plate protrusion was measured between the EADHP distal tip and the distal humerus. We set the level of unacceptable EADHP anatomic fit mismatch as ≥10 mm plate protrusion. RESULTS: A significant negative linear correlation was also confirmed between humeral size and plate protrusion, with a coefficient of determination of 0.477 for humeral length and 0.814 for distal humeral width. The cutoff value of humeral length to avoid ≥10 mm plate protrusion was 293.6 mm (sensitivity, 88.9%; specificity, 81.8%) and for distal humeral width was 60.5 mm (sensitivity, 100%; specificity, 81.8%). CONCLUSIONS: Anatomic fit mismatch in distal humeral fractures after EADHP fixation has a negative linear correlation with humeral length and distal humeral width. For patients with a distal humeral width <60.5 mm, ≥10 mm plate protrusion will occur when an EADHP is used, and an alternative implant or approach should be considered.
format Online
Article
Text
id pubmed-8181839
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Shoulder and Elbow Society
record_format MEDLINE/PubMed
spelling pubmed-81818392021-06-15 Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study Lim, Joon-Ryul Yoon, Tae-Hwan Lee, Hwan-Mo Chun, Yong-Min Clin Shoulder Elb Original Article BACKGROUND: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict the occurrence of anatomic fit mismatch. We hypothesized that the smaller the humerus size, the greater the anatomic fit mismatch with EADHP. METHODS: Twenty humeri were analyzed in this study. Humeral length and distal humeral width were used as parameters of humeral size. Plate protrusion was measured between the EADHP distal tip and the distal humerus. We set the level of unacceptable EADHP anatomic fit mismatch as ≥10 mm plate protrusion. RESULTS: A significant negative linear correlation was also confirmed between humeral size and plate protrusion, with a coefficient of determination of 0.477 for humeral length and 0.814 for distal humeral width. The cutoff value of humeral length to avoid ≥10 mm plate protrusion was 293.6 mm (sensitivity, 88.9%; specificity, 81.8%) and for distal humeral width was 60.5 mm (sensitivity, 100%; specificity, 81.8%). CONCLUSIONS: Anatomic fit mismatch in distal humeral fractures after EADHP fixation has a negative linear correlation with humeral length and distal humeral width. For patients with a distal humeral width <60.5 mm, ≥10 mm plate protrusion will occur when an EADHP is used, and an alternative implant or approach should be considered. Korean Shoulder and Elbow Society 2021-05-27 /pmc/articles/PMC8181839/ /pubmed/34078013 http://dx.doi.org/10.5397/cise.2021.00227 Text en Copyright © 2021 Korean Shoulder and Elbow Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lim, Joon-Ryul
Yoon, Tae-Hwan
Lee, Hwan-Mo
Chun, Yong-Min
Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study
title Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study
title_full Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study
title_fullStr Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study
title_full_unstemmed Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study
title_short Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study
title_sort anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8181839/
https://www.ncbi.nlm.nih.gov/pubmed/34078013
http://dx.doi.org/10.5397/cise.2021.00227
work_keys_str_mv AT limjoonryul anatomicfitofprecontouredextraarticulardistalhumerallockingplatesacadavericstudy
AT yoontaehwan anatomicfitofprecontouredextraarticulardistalhumerallockingplatesacadavericstudy
AT leehwanmo anatomicfitofprecontouredextraarticulardistalhumerallockingplatesacadavericstudy
AT chunyongmin anatomicfitofprecontouredextraarticulardistalhumerallockingplatesacadavericstudy