Cargando…
Clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer
BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration is recommended for lymph node (LN) staging in lung cancer. Although 22-gauge needles are widely used, they may make some stations difficult to puncture owing to an acute angle. A thinner 25-gauge needle was introduced in Ja...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182540/ https://www.ncbi.nlm.nih.gov/pubmed/34164194 http://dx.doi.org/10.21037/jtd-20-3383 |
_version_ | 1783704228185767936 |
---|---|
author | Okubo, Yu Matsumoto, Yuji Tanaka, Midori Imabayashi, Tatsuya Uezono, Yasuhito Watanabe, Shun-ichi Tsuchida, Takaaki |
author_facet | Okubo, Yu Matsumoto, Yuji Tanaka, Midori Imabayashi, Tatsuya Uezono, Yasuhito Watanabe, Shun-ichi Tsuchida, Takaaki |
author_sort | Okubo, Yu |
collection | PubMed |
description | BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration is recommended for lymph node (LN) staging in lung cancer. Although 22-gauge needles are widely used, they may make some stations difficult to puncture owing to an acute angle. A thinner 25-gauge needle was introduced in Japan at the end of 2016 and offered structural advantages such as improved flexibility and penetrability. We aimed to validate the clinical utility of the 25-gauge needle in LN staging. METHODS: Patients who underwent endobronchial ultrasound-guided transbronchial needle aspiration for LN staging of lung cancer using the 25-gauge needle at our institution between November 2016 and March 2019 were included. Patient characteristics, staging procedures, pathology findings, and genetic testing success rates were assessed. RESULTS: Data of 130 patients were included in the analysis. The sampling rate was 87.6% (589/672 lesions). In addition to stations #4R, #7, and #11, which are generally easy to puncture, multiple stations (40.1%) were sampled. The diagnostic accuracy of combined computed tomography and fluorodeoxyglucose positron emission tomography was 82.3% and that of additional endobronchial ultrasound-guided transbronchial needle aspiration was 96.9%. The overall sensitivity, specificity, and positive and negative predictive values validated using resected specimens were 97.1% (34/35), 100% (41/41), 100% (34/34), and 97.6% (41/42), respectively. The success rate of genetic testing was 100% (34/34). CONCLUSIONS: The new 25-gauge needle enabled us to approach a wide range of LNs with a desirable sampling rate and diagnostic accuracy in LN staging using endobronchial ultrasound-guided transbronchial needle aspiration, while providing enough tissue for genetic testing. |
format | Online Article Text |
id | pubmed-8182540 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-81825402021-06-22 Clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer Okubo, Yu Matsumoto, Yuji Tanaka, Midori Imabayashi, Tatsuya Uezono, Yasuhito Watanabe, Shun-ichi Tsuchida, Takaaki J Thorac Dis Original Article BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration is recommended for lymph node (LN) staging in lung cancer. Although 22-gauge needles are widely used, they may make some stations difficult to puncture owing to an acute angle. A thinner 25-gauge needle was introduced in Japan at the end of 2016 and offered structural advantages such as improved flexibility and penetrability. We aimed to validate the clinical utility of the 25-gauge needle in LN staging. METHODS: Patients who underwent endobronchial ultrasound-guided transbronchial needle aspiration for LN staging of lung cancer using the 25-gauge needle at our institution between November 2016 and March 2019 were included. Patient characteristics, staging procedures, pathology findings, and genetic testing success rates were assessed. RESULTS: Data of 130 patients were included in the analysis. The sampling rate was 87.6% (589/672 lesions). In addition to stations #4R, #7, and #11, which are generally easy to puncture, multiple stations (40.1%) were sampled. The diagnostic accuracy of combined computed tomography and fluorodeoxyglucose positron emission tomography was 82.3% and that of additional endobronchial ultrasound-guided transbronchial needle aspiration was 96.9%. The overall sensitivity, specificity, and positive and negative predictive values validated using resected specimens were 97.1% (34/35), 100% (41/41), 100% (34/34), and 97.6% (41/42), respectively. The success rate of genetic testing was 100% (34/34). CONCLUSIONS: The new 25-gauge needle enabled us to approach a wide range of LNs with a desirable sampling rate and diagnostic accuracy in LN staging using endobronchial ultrasound-guided transbronchial needle aspiration, while providing enough tissue for genetic testing. AME Publishing Company 2021-05 /pmc/articles/PMC8182540/ /pubmed/34164194 http://dx.doi.org/10.21037/jtd-20-3383 Text en 2021 Journal of Thoracic Disease. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Okubo, Yu Matsumoto, Yuji Tanaka, Midori Imabayashi, Tatsuya Uezono, Yasuhito Watanabe, Shun-ichi Tsuchida, Takaaki Clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer |
title | Clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer |
title_full | Clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer |
title_fullStr | Clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer |
title_full_unstemmed | Clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer |
title_short | Clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer |
title_sort | clinical validity of 25-gauge endobronchial ultrasound-guided transbronchial needle in lymph node staging of lung cancer |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182540/ https://www.ncbi.nlm.nih.gov/pubmed/34164194 http://dx.doi.org/10.21037/jtd-20-3383 |
work_keys_str_mv | AT okuboyu clinicalvalidityof25gaugeendobronchialultrasoundguidedtransbronchialneedleinlymphnodestagingoflungcancer AT matsumotoyuji clinicalvalidityof25gaugeendobronchialultrasoundguidedtransbronchialneedleinlymphnodestagingoflungcancer AT tanakamidori clinicalvalidityof25gaugeendobronchialultrasoundguidedtransbronchialneedleinlymphnodestagingoflungcancer AT imabayashitatsuya clinicalvalidityof25gaugeendobronchialultrasoundguidedtransbronchialneedleinlymphnodestagingoflungcancer AT uezonoyasuhito clinicalvalidityof25gaugeendobronchialultrasoundguidedtransbronchialneedleinlymphnodestagingoflungcancer AT watanabeshunichi clinicalvalidityof25gaugeendobronchialultrasoundguidedtransbronchialneedleinlymphnodestagingoflungcancer AT tsuchidatakaaki clinicalvalidityof25gaugeendobronchialultrasoundguidedtransbronchialneedleinlymphnodestagingoflungcancer |