Cargando…

Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists

BACKGROUND: Despite the decreasing relevance of chest radiography in lung cancer screening, chest radiography is still frequently applied to assess for lung nodules. The aim of the current study was to determine the accuracy of a commercial AI based CAD system for the detection of artificial lung no...

Descripción completa

Detalles Bibliográficos
Autores principales: Peters, Alan A., Decasper, Amanda, Munz, Jaro, Klaus, Jeremias, Loebelenz, Laura I., Hoffner, Maximilian Korbinian Michael, Hourscht, Cynthia, Heverhagen, Johannes T., Christe, Andreas, Ebner, Lukas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182550/
https://www.ncbi.nlm.nih.gov/pubmed/34164165
http://dx.doi.org/10.21037/jtd-20-3522
_version_ 1783704230571278336
author Peters, Alan A.
Decasper, Amanda
Munz, Jaro
Klaus, Jeremias
Loebelenz, Laura I.
Hoffner, Maximilian Korbinian Michael
Hourscht, Cynthia
Heverhagen, Johannes T.
Christe, Andreas
Ebner, Lukas
author_facet Peters, Alan A.
Decasper, Amanda
Munz, Jaro
Klaus, Jeremias
Loebelenz, Laura I.
Hoffner, Maximilian Korbinian Michael
Hourscht, Cynthia
Heverhagen, Johannes T.
Christe, Andreas
Ebner, Lukas
author_sort Peters, Alan A.
collection PubMed
description BACKGROUND: Despite the decreasing relevance of chest radiography in lung cancer screening, chest radiography is still frequently applied to assess for lung nodules. The aim of the current study was to determine the accuracy of a commercial AI based CAD system for the detection of artificial lung nodules on chest radiograph phantoms and compare the performance to radiologists in training. METHODS: Sixty-one anthropomorphic lung phantoms were equipped with 140 randomly deployed artificial lung nodules (5, 8, 10, 12 mm). A random generator chose nodule size and distribution before a two-plane chest X-ray (CXR) of each phantom was performed. Seven blinded radiologists in training (2 fellows, 5 residents) with 2 to 5 years of experience in chest imaging read the CXRs on a PACS-workstation independently. Results of the software were recorded separately. McNemar test was used to compare each radiologist’s results to the AI-computer-aided-diagnostic (CAD) software in a per-nodule and a per-phantom approach and Fleiss-Kappa was applied for inter-rater and intra-observer agreements. RESULTS: Five out of seven readers showed a significantly higher accuracy than the AI algorithm. The pooled accuracies of the radiologists in a nodule-based and a phantom-based approach were 0.59 and 0.82 respectively, whereas the AI-CAD showed accuracies of 0.47 and 0.67, respectively. Radiologists’ average sensitivity for 10 and 12 mm nodules was 0.80 and dropped to 0.66 for 8 mm (P=0.04) and 0.14 for 5 mm nodules (P<0.001). The radiologists and the algorithm both demonstrated a significant higher sensitivity for peripheral compared to central nodules (0.66 vs. 0.48; P=0.004 and 0.64 vs. 0.094; P=0.025, respectively). Inter-rater agreements were moderate among the radiologists and between radiologists and AI-CAD software (K’=0.58±0.13 and 0.51±0.1). Intra-observer agreement was calculated for two readers and was almost perfect for the phantom-based (K’=0.85±0.05; K’=0.80±0.02); and substantial to almost perfect for the nodule-based approach (K’=0.83±0.02; K’=0.78±0.02). CONCLUSIONS: The AI based CAD system as a primary reader acts inferior to radiologists regarding lung nodule detection in chest phantoms. Chest radiography has reasonable accuracy in lung nodule detection if read by a radiologist alone and may be further optimized by an AI based CAD system as a second reader.
format Online
Article
Text
id pubmed-8182550
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-81825502021-06-22 Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists Peters, Alan A. Decasper, Amanda Munz, Jaro Klaus, Jeremias Loebelenz, Laura I. Hoffner, Maximilian Korbinian Michael Hourscht, Cynthia Heverhagen, Johannes T. Christe, Andreas Ebner, Lukas J Thorac Dis Original Article BACKGROUND: Despite the decreasing relevance of chest radiography in lung cancer screening, chest radiography is still frequently applied to assess for lung nodules. The aim of the current study was to determine the accuracy of a commercial AI based CAD system for the detection of artificial lung nodules on chest radiograph phantoms and compare the performance to radiologists in training. METHODS: Sixty-one anthropomorphic lung phantoms were equipped with 140 randomly deployed artificial lung nodules (5, 8, 10, 12 mm). A random generator chose nodule size and distribution before a two-plane chest X-ray (CXR) of each phantom was performed. Seven blinded radiologists in training (2 fellows, 5 residents) with 2 to 5 years of experience in chest imaging read the CXRs on a PACS-workstation independently. Results of the software were recorded separately. McNemar test was used to compare each radiologist’s results to the AI-computer-aided-diagnostic (CAD) software in a per-nodule and a per-phantom approach and Fleiss-Kappa was applied for inter-rater and intra-observer agreements. RESULTS: Five out of seven readers showed a significantly higher accuracy than the AI algorithm. The pooled accuracies of the radiologists in a nodule-based and a phantom-based approach were 0.59 and 0.82 respectively, whereas the AI-CAD showed accuracies of 0.47 and 0.67, respectively. Radiologists’ average sensitivity for 10 and 12 mm nodules was 0.80 and dropped to 0.66 for 8 mm (P=0.04) and 0.14 for 5 mm nodules (P<0.001). The radiologists and the algorithm both demonstrated a significant higher sensitivity for peripheral compared to central nodules (0.66 vs. 0.48; P=0.004 and 0.64 vs. 0.094; P=0.025, respectively). Inter-rater agreements were moderate among the radiologists and between radiologists and AI-CAD software (K’=0.58±0.13 and 0.51±0.1). Intra-observer agreement was calculated for two readers and was almost perfect for the phantom-based (K’=0.85±0.05; K’=0.80±0.02); and substantial to almost perfect for the nodule-based approach (K’=0.83±0.02; K’=0.78±0.02). CONCLUSIONS: The AI based CAD system as a primary reader acts inferior to radiologists regarding lung nodule detection in chest phantoms. Chest radiography has reasonable accuracy in lung nodule detection if read by a radiologist alone and may be further optimized by an AI based CAD system as a second reader. AME Publishing Company 2021-05 /pmc/articles/PMC8182550/ /pubmed/34164165 http://dx.doi.org/10.21037/jtd-20-3522 Text en 2021 Journal of Thoracic Disease. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Peters, Alan A.
Decasper, Amanda
Munz, Jaro
Klaus, Jeremias
Loebelenz, Laura I.
Hoffner, Maximilian Korbinian Michael
Hourscht, Cynthia
Heverhagen, Johannes T.
Christe, Andreas
Ebner, Lukas
Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists
title Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists
title_full Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists
title_fullStr Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists
title_full_unstemmed Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists
title_short Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists
title_sort performance of an ai based cad system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182550/
https://www.ncbi.nlm.nih.gov/pubmed/34164165
http://dx.doi.org/10.21037/jtd-20-3522
work_keys_str_mv AT petersalana performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT decasperamanda performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT munzjaro performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT klausjeremias performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT loebelenzlaurai performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT hoffnermaximiliankorbinianmichael performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT hourschtcynthia performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT heverhagenjohannest performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT christeandreas performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists
AT ebnerlukas performanceofanaibasedcadsysteminsolidlungnoduledetectiononchestphantomradiographscomparedtoradiologyresidentsandfellowradiologists