Cargando…

Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced

Users of a cochlear implant (CI) in one ear, who are provided with a hearing aid (HA) in the contralateral ear, so-called bimodal listeners, are typically affected by a constant and relatively large interaural time delay offset due to differences in signal processing and differences in stimulation....

Descripción completa

Detalles Bibliográficos
Autores principales: Angermeier, Julian, Hemmert, Werner, Zirn, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182625/
https://www.ncbi.nlm.nih.gov/pubmed/34057366
http://dx.doi.org/10.1177/23312165211016165
_version_ 1783704248341495808
author Angermeier, Julian
Hemmert, Werner
Zirn, Stefan
author_facet Angermeier, Julian
Hemmert, Werner
Zirn, Stefan
author_sort Angermeier, Julian
collection PubMed
description Users of a cochlear implant (CI) in one ear, who are provided with a hearing aid (HA) in the contralateral ear, so-called bimodal listeners, are typically affected by a constant and relatively large interaural time delay offset due to differences in signal processing and differences in stimulation. For HA stimulation, the cochlear travelling wave delay is added to the processing delay, while for CI stimulation, the auditory nerve fibers are stimulated directly. In case of MED-EL CI systems in combination with different HA types, the CI stimulation precedes the acoustic HA stimulation by 3 to 10 ms. A self-designed, battery-powered, portable, and programmable delay line was applied to the CI to reduce the device delay mismatch in nine bimodal listeners. We used an A-B-B-A test design and determined if sound source localization improves when the device delay mismatch is reduced by delaying the CI stimulation by the HA processing delay (τ(HA)). Results revealed that every subject in our group of nine bimodal listeners benefited from the approach. The root-mean-square error of sound localization improved significantly from 52.6° to 37.9°. The signed bias also improved significantly from 25.2° to 10.5°, with positive values indicating a bias toward the CI. Furthermore, two other delay values (τ(HA) –1 ms and τ(HA) +1 ms) were applied, and with the latter value, the signed bias was further reduced in some test subjects. We conclude that sound source localization accuracy in bimodal listeners improves instantaneously and sustainably when the device delay mismatch is reduced.
format Online
Article
Text
id pubmed-8182625
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-81826252021-06-21 Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced Angermeier, Julian Hemmert, Werner Zirn, Stefan Trends Hear Original Article Users of a cochlear implant (CI) in one ear, who are provided with a hearing aid (HA) in the contralateral ear, so-called bimodal listeners, are typically affected by a constant and relatively large interaural time delay offset due to differences in signal processing and differences in stimulation. For HA stimulation, the cochlear travelling wave delay is added to the processing delay, while for CI stimulation, the auditory nerve fibers are stimulated directly. In case of MED-EL CI systems in combination with different HA types, the CI stimulation precedes the acoustic HA stimulation by 3 to 10 ms. A self-designed, battery-powered, portable, and programmable delay line was applied to the CI to reduce the device delay mismatch in nine bimodal listeners. We used an A-B-B-A test design and determined if sound source localization improves when the device delay mismatch is reduced by delaying the CI stimulation by the HA processing delay (τ(HA)). Results revealed that every subject in our group of nine bimodal listeners benefited from the approach. The root-mean-square error of sound localization improved significantly from 52.6° to 37.9°. The signed bias also improved significantly from 25.2° to 10.5°, with positive values indicating a bias toward the CI. Furthermore, two other delay values (τ(HA) –1 ms and τ(HA) +1 ms) were applied, and with the latter value, the signed bias was further reduced in some test subjects. We conclude that sound source localization accuracy in bimodal listeners improves instantaneously and sustainably when the device delay mismatch is reduced. SAGE Publications 2021-05-31 /pmc/articles/PMC8182625/ /pubmed/34057366 http://dx.doi.org/10.1177/23312165211016165 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Creative Commons CC BY: This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Angermeier, Julian
Hemmert, Werner
Zirn, Stefan
Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced
title Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced
title_full Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced
title_fullStr Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced
title_full_unstemmed Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced
title_short Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced
title_sort sound localization bias and error in bimodal listeners improve instantaneously when the device delay mismatch is reduced
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182625/
https://www.ncbi.nlm.nih.gov/pubmed/34057366
http://dx.doi.org/10.1177/23312165211016165
work_keys_str_mv AT angermeierjulian soundlocalizationbiasanderrorinbimodallistenersimproveinstantaneouslywhenthedevicedelaymismatchisreduced
AT hemmertwerner soundlocalizationbiasanderrorinbimodallistenersimproveinstantaneouslywhenthedevicedelaymismatchisreduced
AT zirnstefan soundlocalizationbiasanderrorinbimodallistenersimproveinstantaneouslywhenthedevicedelaymismatchisreduced