Cargando…
Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region
BACKGROUND: We investigated the geometric and dosimetric impact of three-dimensional (3D) generative adversarial network (GAN)-based metal artifact reduction (MAR) algorithms on volumetric-modulated arc therapy (VMAT) and intensity-modulated proton therapy (IMPT) for the head and neck region, based...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182914/ https://www.ncbi.nlm.nih.gov/pubmed/34092240 http://dx.doi.org/10.1186/s13014-021-01827-0 |
_version_ | 1783704281986105344 |
---|---|
author | Nakamura, Mitsuhiro Nakao, Megumi Imanishi, Keiho Hirashima, Hideaki Tsuruta, Yusuke |
author_facet | Nakamura, Mitsuhiro Nakao, Megumi Imanishi, Keiho Hirashima, Hideaki Tsuruta, Yusuke |
author_sort | Nakamura, Mitsuhiro |
collection | PubMed |
description | BACKGROUND: We investigated the geometric and dosimetric impact of three-dimensional (3D) generative adversarial network (GAN)-based metal artifact reduction (MAR) algorithms on volumetric-modulated arc therapy (VMAT) and intensity-modulated proton therapy (IMPT) for the head and neck region, based on artifact-free computed tomography (CT) volumes with dental fillings. METHODS: Thirteen metal-free CT volumes of the head and neck regions were obtained from The Cancer Imaging Archive. To simulate metal artifacts on CT volumes, we defined 3D regions of the teeth for pseudo-dental fillings from the metal-free CT volumes. HU values of 4000 HU were assigned to the selected teeth region of interest. Two different CT volumes, one with four (m4) and the other with eight (m8) pseudo-dental fillings, were generated for each case. These CT volumes were used as the Reference. CT volumes with metal artifacts were then generated from the Reference CT volumes (Artifacts). On the Artifacts CT volumes, metal artifacts were manually corrected for using the water density override method with a value of 1.0 g/cm(3) (Water). By contrast, the CT volumes with reduced metal artifacts using 3D GAN model extension of CycleGAN were also generated (GAN-MAR). The structural similarity (SSIM) index within the planning target volume was calculated as quantitative error metric between the Reference CT volumes and the other volumes. After creating VMAT and IMPT plans on the Reference CT volumes, the reference plans were recalculated for the remaining CT volumes. RESULTS: The time required to generate a single GAN-MAR CT volume was approximately 30 s. The median SSIMs were lower in the m8 group than those in the m4 group, and ANOVA showed a significant difference in the SSIM for the m8 group (p < 0.05). Although the median differences in D(98%), D(50%) and D(2%) were larger in the m8 group than the m4 group, those from the reference plans were within 3% for VMAT and 1% for IMPT. CONCLUSIONS: The GAN-MAR CT volumes generated in a short time were closer to the Reference CT volumes than the Water and Artifacts CT volumes. The observed dosimetric differences compared to the reference plan were clinically acceptable. |
format | Online Article Text |
id | pubmed-8182914 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-81829142021-06-09 Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region Nakamura, Mitsuhiro Nakao, Megumi Imanishi, Keiho Hirashima, Hideaki Tsuruta, Yusuke Radiat Oncol Research BACKGROUND: We investigated the geometric and dosimetric impact of three-dimensional (3D) generative adversarial network (GAN)-based metal artifact reduction (MAR) algorithms on volumetric-modulated arc therapy (VMAT) and intensity-modulated proton therapy (IMPT) for the head and neck region, based on artifact-free computed tomography (CT) volumes with dental fillings. METHODS: Thirteen metal-free CT volumes of the head and neck regions were obtained from The Cancer Imaging Archive. To simulate metal artifacts on CT volumes, we defined 3D regions of the teeth for pseudo-dental fillings from the metal-free CT volumes. HU values of 4000 HU were assigned to the selected teeth region of interest. Two different CT volumes, one with four (m4) and the other with eight (m8) pseudo-dental fillings, were generated for each case. These CT volumes were used as the Reference. CT volumes with metal artifacts were then generated from the Reference CT volumes (Artifacts). On the Artifacts CT volumes, metal artifacts were manually corrected for using the water density override method with a value of 1.0 g/cm(3) (Water). By contrast, the CT volumes with reduced metal artifacts using 3D GAN model extension of CycleGAN were also generated (GAN-MAR). The structural similarity (SSIM) index within the planning target volume was calculated as quantitative error metric between the Reference CT volumes and the other volumes. After creating VMAT and IMPT plans on the Reference CT volumes, the reference plans were recalculated for the remaining CT volumes. RESULTS: The time required to generate a single GAN-MAR CT volume was approximately 30 s. The median SSIMs were lower in the m8 group than those in the m4 group, and ANOVA showed a significant difference in the SSIM for the m8 group (p < 0.05). Although the median differences in D(98%), D(50%) and D(2%) were larger in the m8 group than the m4 group, those from the reference plans were within 3% for VMAT and 1% for IMPT. CONCLUSIONS: The GAN-MAR CT volumes generated in a short time were closer to the Reference CT volumes than the Water and Artifacts CT volumes. The observed dosimetric differences compared to the reference plan were clinically acceptable. BioMed Central 2021-06-06 /pmc/articles/PMC8182914/ /pubmed/34092240 http://dx.doi.org/10.1186/s13014-021-01827-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Nakamura, Mitsuhiro Nakao, Megumi Imanishi, Keiho Hirashima, Hideaki Tsuruta, Yusuke Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region |
title | Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region |
title_full | Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region |
title_fullStr | Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region |
title_full_unstemmed | Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region |
title_short | Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region |
title_sort | geometric and dosimetric impact of 3d generative adversarial network-based metal artifact reduction algorithm on vmat and impt for the head and neck region |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182914/ https://www.ncbi.nlm.nih.gov/pubmed/34092240 http://dx.doi.org/10.1186/s13014-021-01827-0 |
work_keys_str_mv | AT nakamuramitsuhiro geometricanddosimetricimpactof3dgenerativeadversarialnetworkbasedmetalartifactreductionalgorithmonvmatandimptfortheheadandneckregion AT nakaomegumi geometricanddosimetricimpactof3dgenerativeadversarialnetworkbasedmetalartifactreductionalgorithmonvmatandimptfortheheadandneckregion AT imanishikeiho geometricanddosimetricimpactof3dgenerativeadversarialnetworkbasedmetalartifactreductionalgorithmonvmatandimptfortheheadandneckregion AT hirashimahideaki geometricanddosimetricimpactof3dgenerativeadversarialnetworkbasedmetalartifactreductionalgorithmonvmatandimptfortheheadandneckregion AT tsurutayusuke geometricanddosimetricimpactof3dgenerativeadversarialnetworkbasedmetalartifactreductionalgorithmonvmatandimptfortheheadandneckregion |