Cargando…

Ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: Clinical characteristics and management

BACKGROUND: Placement of a left ventricular assist device (LVAD) has been described to compromise implantable cardioverter-defibrillator (ICD) defibrillation threshold (DFT). Elevated DFT will have negative consequences and increases the risk of ineffective ICD shocks, morbidity, and mortality. DFT...

Descripción completa

Detalles Bibliográficos
Autores principales: Shehadeh, Malik, Brar, Vijaywant, Costello, John, Hadadi, Cyrus, O’Donoghue, Susan, Worley, Seth
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8183971/
https://www.ncbi.nlm.nih.gov/pubmed/34113891
http://dx.doi.org/10.1016/j.hroo.2020.11.001
_version_ 1783704493976715264
author Shehadeh, Malik
Brar, Vijaywant
Costello, John
Hadadi, Cyrus
O’Donoghue, Susan
Worley, Seth
author_facet Shehadeh, Malik
Brar, Vijaywant
Costello, John
Hadadi, Cyrus
O’Donoghue, Susan
Worley, Seth
author_sort Shehadeh, Malik
collection PubMed
description BACKGROUND: Placement of a left ventricular assist device (LVAD) has been described to compromise implantable cardioverter-defibrillator (ICD) defibrillation threshold (DFT). Elevated DFT will have negative consequences and increases the risk of ineffective ICD shocks, morbidity, and mortality. DFT testing is not routinely performed in clinical practice, despite this fact. OBJECTIVE: We describe the clinical characteristics of 7 LVAD patients who presented with multiple ineffective ICD shocks, along with the management strategy in such patients. METHODS: Seven patients (5 male, mean age 52.2 ± 9 years, 85.7% nonischemic cardiomyopathy) with an ICD in situ who progressed to NYHA class IV, ACC/AHA stage D chronic systolic congestive heart failure who underwent successful LVAD implantation presented to our institution in the setting of ventricular tachyarrhythmia and ineffective ICD shocks. Six patients underwent implantation of azygos and subclavian coils with subsequent DFT testing. The remaining patient was made comfort care. RESULTS: Five patients had successful DFT testing with azygos (n = 4) and subclavian (n = 1) defibrillation coil implantation. One patient had unsuccessful DFT testing despite evaluation of multiple shock vectors. There were no major or minor vascular complications in any of the cases. There were no procedural-related deaths. CONCLUSION: This case series highlights the need for a systematic approach to management of ICDs and DFT testing in LVAD patients. The addition of new shock vectors with azygos and subclavian coil implantation may reduce DFT, shock burden, morbidity, and mortality.
format Online
Article
Text
id pubmed-8183971
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-81839712021-06-09 Ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: Clinical characteristics and management Shehadeh, Malik Brar, Vijaywant Costello, John Hadadi, Cyrus O’Donoghue, Susan Worley, Seth Heart Rhythm O2 Clinical BACKGROUND: Placement of a left ventricular assist device (LVAD) has been described to compromise implantable cardioverter-defibrillator (ICD) defibrillation threshold (DFT). Elevated DFT will have negative consequences and increases the risk of ineffective ICD shocks, morbidity, and mortality. DFT testing is not routinely performed in clinical practice, despite this fact. OBJECTIVE: We describe the clinical characteristics of 7 LVAD patients who presented with multiple ineffective ICD shocks, along with the management strategy in such patients. METHODS: Seven patients (5 male, mean age 52.2 ± 9 years, 85.7% nonischemic cardiomyopathy) with an ICD in situ who progressed to NYHA class IV, ACC/AHA stage D chronic systolic congestive heart failure who underwent successful LVAD implantation presented to our institution in the setting of ventricular tachyarrhythmia and ineffective ICD shocks. Six patients underwent implantation of azygos and subclavian coils with subsequent DFT testing. The remaining patient was made comfort care. RESULTS: Five patients had successful DFT testing with azygos (n = 4) and subclavian (n = 1) defibrillation coil implantation. One patient had unsuccessful DFT testing despite evaluation of multiple shock vectors. There were no major or minor vascular complications in any of the cases. There were no procedural-related deaths. CONCLUSION: This case series highlights the need for a systematic approach to management of ICDs and DFT testing in LVAD patients. The addition of new shock vectors with azygos and subclavian coil implantation may reduce DFT, shock burden, morbidity, and mortality. Elsevier 2020-11-06 /pmc/articles/PMC8183971/ /pubmed/34113891 http://dx.doi.org/10.1016/j.hroo.2020.11.001 Text en © 2020 Heart Rhythm Society. Published by Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Clinical
Shehadeh, Malik
Brar, Vijaywant
Costello, John
Hadadi, Cyrus
O’Donoghue, Susan
Worley, Seth
Ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: Clinical characteristics and management
title Ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: Clinical characteristics and management
title_full Ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: Clinical characteristics and management
title_fullStr Ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: Clinical characteristics and management
title_full_unstemmed Ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: Clinical characteristics and management
title_short Ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: Clinical characteristics and management
title_sort ineffective implantable cardioverter-defibrillator shocks among patients on continuous left ventricular assist device support: clinical characteristics and management
topic Clinical
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8183971/
https://www.ncbi.nlm.nih.gov/pubmed/34113891
http://dx.doi.org/10.1016/j.hroo.2020.11.001
work_keys_str_mv AT shehadehmalik ineffectiveimplantablecardioverterdefibrillatorshocksamongpatientsoncontinuousleftventricularassistdevicesupportclinicalcharacteristicsandmanagement
AT brarvijaywant ineffectiveimplantablecardioverterdefibrillatorshocksamongpatientsoncontinuousleftventricularassistdevicesupportclinicalcharacteristicsandmanagement
AT costellojohn ineffectiveimplantablecardioverterdefibrillatorshocksamongpatientsoncontinuousleftventricularassistdevicesupportclinicalcharacteristicsandmanagement
AT hadadicyrus ineffectiveimplantablecardioverterdefibrillatorshocksamongpatientsoncontinuousleftventricularassistdevicesupportclinicalcharacteristicsandmanagement
AT odonoghuesusan ineffectiveimplantablecardioverterdefibrillatorshocksamongpatientsoncontinuousleftventricularassistdevicesupportclinicalcharacteristicsandmanagement
AT worleyseth ineffectiveimplantablecardioverterdefibrillatorshocksamongpatientsoncontinuousleftventricularassistdevicesupportclinicalcharacteristicsandmanagement