Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation

Purpose To determine the appropriateness of implementing Mobius3D/FX (Varian Medical Systems, Inc., Palo Alto, CA, USA) as not only a pretreatment secondary check but as an alternative to measurement-based patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods...

Descripción completa

Detalles Bibliográficos
Autores principales: Basavatia, Amar K, Fiedler, Derek A, Ritter, Johannes, Brodin, Patrik, Goddard, Lee C, Jeong, Kyoungkeun, Hsu, Shu-Hui, Mynampati, Dinesh K, Yaparpalvi, Ravindra, Tomé, Wolfgang A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8184160/
https://www.ncbi.nlm.nih.gov/pubmed/34113520
http://dx.doi.org/10.7759/cureus.14910
_version_ 1783704533102231552
author Basavatia, Amar K
Fiedler, Derek A
Ritter, Johannes
Brodin, Patrik
Goddard, Lee C
Jeong, Kyoungkeun
Hsu, Shu-Hui
Mynampati, Dinesh K
Yaparpalvi, Ravindra
Tomé, Wolfgang A
author_facet Basavatia, Amar K
Fiedler, Derek A
Ritter, Johannes
Brodin, Patrik
Goddard, Lee C
Jeong, Kyoungkeun
Hsu, Shu-Hui
Mynampati, Dinesh K
Yaparpalvi, Ravindra
Tomé, Wolfgang A
author_sort Basavatia, Amar K
collection PubMed
description Purpose To determine the appropriateness of implementing Mobius3D/FX (Varian Medical Systems, Inc., Palo Alto, CA, USA) as not only a pretreatment secondary check but as an alternative to measurement-based patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods Mobius3D/FX was commissioned and stock beam models were tweaked so that an independent recalculated 3D dose distribution can be obtained. Then, 50 patient-specific treatment plans for various indications were delivered across a 2D ion chamber array, radiochromic film setup, and electronic portal imager and analyzed with MobiusFX and gamma analysis. The concordance of plans scored as passing between MobiusFX and the conventional methods of QA was determined. Results All analyzed treatment plans passed with a gamma passing rate >90% across all conventional QA methods, most commonly using a 3%/3mm gamma criterion except for film measurements where a 5%/3mm criterion was applied. There was good agreement and concordance between MobiusFX and conventional methods when using a 3%/3mm criteria for MobiusFX, whereas a 2%/2mm criteria appeared too stringent as it failed treatment plans deemed clinically acceptable using conventional methods. Conclusions Using a 50-sample subset of clinically delivered treatment plans this non-inferiority-type comparison shows Mobius3D/FX based on log file analysis to be a suitable alternative to conventional QA methods when utilizing the 3%/3mm gamma criterion. Methods based on log file analysis can provide an opportunity for resource sparing, improving the efficiency, and workflow for evaluating IMRT treatment plans.
format Online
Article
Text
id pubmed-8184160
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-81841602021-06-09 Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation Basavatia, Amar K Fiedler, Derek A Ritter, Johannes Brodin, Patrik Goddard, Lee C Jeong, Kyoungkeun Hsu, Shu-Hui Mynampati, Dinesh K Yaparpalvi, Ravindra Tomé, Wolfgang A Cureus Medical Physics Purpose To determine the appropriateness of implementing Mobius3D/FX (Varian Medical Systems, Inc., Palo Alto, CA, USA) as not only a pretreatment secondary check but as an alternative to measurement-based patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods Mobius3D/FX was commissioned and stock beam models were tweaked so that an independent recalculated 3D dose distribution can be obtained. Then, 50 patient-specific treatment plans for various indications were delivered across a 2D ion chamber array, radiochromic film setup, and electronic portal imager and analyzed with MobiusFX and gamma analysis. The concordance of plans scored as passing between MobiusFX and the conventional methods of QA was determined. Results All analyzed treatment plans passed with a gamma passing rate >90% across all conventional QA methods, most commonly using a 3%/3mm gamma criterion except for film measurements where a 5%/3mm criterion was applied. There was good agreement and concordance between MobiusFX and conventional methods when using a 3%/3mm criteria for MobiusFX, whereas a 2%/2mm criteria appeared too stringent as it failed treatment plans deemed clinically acceptable using conventional methods. Conclusions Using a 50-sample subset of clinically delivered treatment plans this non-inferiority-type comparison shows Mobius3D/FX based on log file analysis to be a suitable alternative to conventional QA methods when utilizing the 3%/3mm gamma criterion. Methods based on log file analysis can provide an opportunity for resource sparing, improving the efficiency, and workflow for evaluating IMRT treatment plans. Cureus 2021-05-08 /pmc/articles/PMC8184160/ /pubmed/34113520 http://dx.doi.org/10.7759/cureus.14910 Text en Copyright © 2021, Basavatia et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Physics
Basavatia, Amar K
Fiedler, Derek A
Ritter, Johannes
Brodin, Patrik
Goddard, Lee C
Jeong, Kyoungkeun
Hsu, Shu-Hui
Mynampati, Dinesh K
Yaparpalvi, Ravindra
Tomé, Wolfgang A
Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation
title Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation
title_full Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation
title_fullStr Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation
title_full_unstemmed Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation
title_short Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation
title_sort comprehensive patient-specific intensity-modulated radiation therapy quality assurance comparing mobius3d/fx to conventional methods of evaluation
topic Medical Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8184160/
https://www.ncbi.nlm.nih.gov/pubmed/34113520
http://dx.doi.org/10.7759/cureus.14910
work_keys_str_mv AT basavatiaamark comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT fiedlerdereka comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT ritterjohannes comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT brodinpatrik comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT goddardleec comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT jeongkyoungkeun comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT hsushuhui comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT mynampatidineshk comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT yaparpalviravindra comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation
AT tomewolfganga comprehensivepatientspecificintensitymodulatedradiationtherapyqualityassurancecomparingmobius3dfxtoconventionalmethodsofevaluation