Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces

Corneal biomechanical parameters were compared in 100 keratoconus eyes with abnormal elevation on the back corneal surface only (group 1), versus both the back and front surfaces (group 2). Scheimpflug tomography with Pentacam HR, corneal biomechanical assessments using Corvis ST and Ocular Response...

Descripción completa

Detalles Bibliográficos
Autores principales: Sedaghat, Mohammad-Reza, Momeni-Moghaddam, Hamed, Roberts, Cynthia J., Maddah, Nasim, Ambrósio, Renato, Hosseini, Seyed Rafi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8184812/
https://www.ncbi.nlm.nih.gov/pubmed/34099765
http://dx.doi.org/10.1038/s41598-021-91263-7
_version_ 1783704656020504576
author Sedaghat, Mohammad-Reza
Momeni-Moghaddam, Hamed
Roberts, Cynthia J.
Maddah, Nasim
Ambrósio, Renato
Hosseini, Seyed Rafi
author_facet Sedaghat, Mohammad-Reza
Momeni-Moghaddam, Hamed
Roberts, Cynthia J.
Maddah, Nasim
Ambrósio, Renato
Hosseini, Seyed Rafi
author_sort Sedaghat, Mohammad-Reza
collection PubMed
description Corneal biomechanical parameters were compared in 100 keratoconus eyes with abnormal elevation on the back corneal surface only (group 1), versus both the back and front surfaces (group 2). Scheimpflug tomography with Pentacam HR, corneal biomechanical assessments using Corvis ST and Ocular Response Analyzer (ORA) and corneal epithelium thickness maps using anterior segment optical coherence tomography were assessed. There were no significant differences in the IOP measured using Corvis ST and ORA, age or sex between the two groups. Statistically significant differences were found in all corneal shape parameters and all new parameters of Corvis ST: corneal stiffness parameter at first applanation (SP-A1), integrated inverse radius (IR) and deformation amplitude ratio (DAR)) between groups (p < 0.001). The classic parameters of ORA including corneal hysteresis (CH) and corneal resistance factor (CRF) were about 1.00 mmHg higher in group 1 (p < 0.001). In conclusion, keratoconus eyes with abnormal elevation limited to the back corneal surface have lower grade, stiffer corneal biomechanical parameters and less asymmetric shape. This is consistent with progressive biomechanical weakening from the first detectable back surface elevation to manifestation on the front surface as the severity overwhelms the ability of the epithelium to compensate.
format Online
Article
Text
id pubmed-8184812
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-81848122021-06-08 Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces Sedaghat, Mohammad-Reza Momeni-Moghaddam, Hamed Roberts, Cynthia J. Maddah, Nasim Ambrósio, Renato Hosseini, Seyed Rafi Sci Rep Article Corneal biomechanical parameters were compared in 100 keratoconus eyes with abnormal elevation on the back corneal surface only (group 1), versus both the back and front surfaces (group 2). Scheimpflug tomography with Pentacam HR, corneal biomechanical assessments using Corvis ST and Ocular Response Analyzer (ORA) and corneal epithelium thickness maps using anterior segment optical coherence tomography were assessed. There were no significant differences in the IOP measured using Corvis ST and ORA, age or sex between the two groups. Statistically significant differences were found in all corneal shape parameters and all new parameters of Corvis ST: corneal stiffness parameter at first applanation (SP-A1), integrated inverse radius (IR) and deformation amplitude ratio (DAR)) between groups (p < 0.001). The classic parameters of ORA including corneal hysteresis (CH) and corneal resistance factor (CRF) were about 1.00 mmHg higher in group 1 (p < 0.001). In conclusion, keratoconus eyes with abnormal elevation limited to the back corneal surface have lower grade, stiffer corneal biomechanical parameters and less asymmetric shape. This is consistent with progressive biomechanical weakening from the first detectable back surface elevation to manifestation on the front surface as the severity overwhelms the ability of the epithelium to compensate. Nature Publishing Group UK 2021-06-07 /pmc/articles/PMC8184812/ /pubmed/34099765 http://dx.doi.org/10.1038/s41598-021-91263-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Sedaghat, Mohammad-Reza
Momeni-Moghaddam, Hamed
Roberts, Cynthia J.
Maddah, Nasim
Ambrósio, Renato
Hosseini, Seyed Rafi
Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces
title Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces
title_full Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces
title_fullStr Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces
title_full_unstemmed Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces
title_short Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces
title_sort corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8184812/
https://www.ncbi.nlm.nih.gov/pubmed/34099765
http://dx.doi.org/10.1038/s41598-021-91263-7
work_keys_str_mv AT sedaghatmohammadreza cornealbiomechanicalparametersinkeratoconuseyeswithabnormalelevationonthebackcornealsurfaceonlyversusbothbackandfrontsurfaces
AT momenimoghaddamhamed cornealbiomechanicalparametersinkeratoconuseyeswithabnormalelevationonthebackcornealsurfaceonlyversusbothbackandfrontsurfaces
AT robertscynthiaj cornealbiomechanicalparametersinkeratoconuseyeswithabnormalelevationonthebackcornealsurfaceonlyversusbothbackandfrontsurfaces
AT maddahnasim cornealbiomechanicalparametersinkeratoconuseyeswithabnormalelevationonthebackcornealsurfaceonlyversusbothbackandfrontsurfaces
AT ambrosiorenato cornealbiomechanicalparametersinkeratoconuseyeswithabnormalelevationonthebackcornealsurfaceonlyversusbothbackandfrontsurfaces
AT hosseiniseyedrafi cornealbiomechanicalparametersinkeratoconuseyeswithabnormalelevationonthebackcornealsurfaceonlyversusbothbackandfrontsurfaces