Association Between Aneurysmal Haemodynamics and Device Microstructural Characteristics After Flow-Diversion Treatments With Dual Stents of Different Sizes: A Numerical Study

OBJECTIVES: Treating intracranial aneurysms with flow-diverting stents sometimes requires deployment of a second device. Herein we quantify the sizing effects of devices in dual-stent treatments upon the final stent microstructure and the post-treatment aneurysmal haemodynamics. METHODS: Fifteen sid...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Mingzi, Tupin, Simon, Li, Yujie, Ohta, Makoto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8185279/
https://www.ncbi.nlm.nih.gov/pubmed/34113263
http://dx.doi.org/10.3389/fphys.2021.663668
_version_ 1783704756180484096
author Zhang, Mingzi
Tupin, Simon
Li, Yujie
Ohta, Makoto
author_facet Zhang, Mingzi
Tupin, Simon
Li, Yujie
Ohta, Makoto
author_sort Zhang, Mingzi
collection PubMed
description OBJECTIVES: Treating intracranial aneurysms with flow-diverting stents sometimes requires deployment of a second device. Herein we quantify the sizing effects of devices in dual-stent treatments upon the final stent microstructure and the post-treatment aneurysmal haemodynamics. METHODS: Fifteen sidewall ICA aneurysm geometries were included. Using a virtual stenting technique, we implanted either one or two stents for each aneurysm treatment considered, with each stent specified as one of two different sizes, yielding a total of two single-stent and fouir dual-stent treatment scenarios for each aneurysm. Three stent microstructural parameters and nine aneurysmal haemodynamic parameters were quantified and systematically compared across the 90 treatment scenarios. RESULTS: Deployment of a second stent further reduced the aneurysmal inflow rate (IR) and energy loss (EL) by, respectively, 14 ± 11% (p = 0.001) and 9 ± 12% (p = 0.056), relative to the untreated condition. Sizing effects of the earlier-deployed stent led to largest differences of 6.9% for the final IR reduction and 11.1% for the EL, whereas sizing effects from the later-deployed stent were minor (≤2.1%). The change in stent pore size was the only microstructural parameter demonstrating a strong correlation with the reduction in the post-treatment aneurysmal haemodynamics, in terms of the IR (r = 0.50, p < 0.001) and pressure drop (r = 0.63, p < 0.001). CONCLUSION: Size of the earlier-deployed stent has substantial effects on the final haemodynamic outcomes after dual-stent treatment. The average pore size of stent wires at the aneurysm orifice shows promise as a potential index for predicting the efficacy of flow-diversion treatments.
format Online
Article
Text
id pubmed-8185279
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-81852792021-06-09 Association Between Aneurysmal Haemodynamics and Device Microstructural Characteristics After Flow-Diversion Treatments With Dual Stents of Different Sizes: A Numerical Study Zhang, Mingzi Tupin, Simon Li, Yujie Ohta, Makoto Front Physiol Physiology OBJECTIVES: Treating intracranial aneurysms with flow-diverting stents sometimes requires deployment of a second device. Herein we quantify the sizing effects of devices in dual-stent treatments upon the final stent microstructure and the post-treatment aneurysmal haemodynamics. METHODS: Fifteen sidewall ICA aneurysm geometries were included. Using a virtual stenting technique, we implanted either one or two stents for each aneurysm treatment considered, with each stent specified as one of two different sizes, yielding a total of two single-stent and fouir dual-stent treatment scenarios for each aneurysm. Three stent microstructural parameters and nine aneurysmal haemodynamic parameters were quantified and systematically compared across the 90 treatment scenarios. RESULTS: Deployment of a second stent further reduced the aneurysmal inflow rate (IR) and energy loss (EL) by, respectively, 14 ± 11% (p = 0.001) and 9 ± 12% (p = 0.056), relative to the untreated condition. Sizing effects of the earlier-deployed stent led to largest differences of 6.9% for the final IR reduction and 11.1% for the EL, whereas sizing effects from the later-deployed stent were minor (≤2.1%). The change in stent pore size was the only microstructural parameter demonstrating a strong correlation with the reduction in the post-treatment aneurysmal haemodynamics, in terms of the IR (r = 0.50, p < 0.001) and pressure drop (r = 0.63, p < 0.001). CONCLUSION: Size of the earlier-deployed stent has substantial effects on the final haemodynamic outcomes after dual-stent treatment. The average pore size of stent wires at the aneurysm orifice shows promise as a potential index for predicting the efficacy of flow-diversion treatments. Frontiers Media S.A. 2021-05-25 /pmc/articles/PMC8185279/ /pubmed/34113263 http://dx.doi.org/10.3389/fphys.2021.663668 Text en Copyright © 2021 Zhang, Tupin, Li and Ohta. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Zhang, Mingzi
Tupin, Simon
Li, Yujie
Ohta, Makoto
Association Between Aneurysmal Haemodynamics and Device Microstructural Characteristics After Flow-Diversion Treatments With Dual Stents of Different Sizes: A Numerical Study
title Association Between Aneurysmal Haemodynamics and Device Microstructural Characteristics After Flow-Diversion Treatments With Dual Stents of Different Sizes: A Numerical Study
title_full Association Between Aneurysmal Haemodynamics and Device Microstructural Characteristics After Flow-Diversion Treatments With Dual Stents of Different Sizes: A Numerical Study
title_fullStr Association Between Aneurysmal Haemodynamics and Device Microstructural Characteristics After Flow-Diversion Treatments With Dual Stents of Different Sizes: A Numerical Study
title_full_unstemmed Association Between Aneurysmal Haemodynamics and Device Microstructural Characteristics After Flow-Diversion Treatments With Dual Stents of Different Sizes: A Numerical Study
title_short Association Between Aneurysmal Haemodynamics and Device Microstructural Characteristics After Flow-Diversion Treatments With Dual Stents of Different Sizes: A Numerical Study
title_sort association between aneurysmal haemodynamics and device microstructural characteristics after flow-diversion treatments with dual stents of different sizes: a numerical study
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8185279/
https://www.ncbi.nlm.nih.gov/pubmed/34113263
http://dx.doi.org/10.3389/fphys.2021.663668
work_keys_str_mv AT zhangmingzi associationbetweenaneurysmalhaemodynamicsanddevicemicrostructuralcharacteristicsafterflowdiversiontreatmentswithdualstentsofdifferentsizesanumericalstudy
AT tupinsimon associationbetweenaneurysmalhaemodynamicsanddevicemicrostructuralcharacteristicsafterflowdiversiontreatmentswithdualstentsofdifferentsizesanumericalstudy
AT liyujie associationbetweenaneurysmalhaemodynamicsanddevicemicrostructuralcharacteristicsafterflowdiversiontreatmentswithdualstentsofdifferentsizesanumericalstudy
AT ohtamakoto associationbetweenaneurysmalhaemodynamicsanddevicemicrostructuralcharacteristicsafterflowdiversiontreatmentswithdualstentsofdifferentsizesanumericalstudy