Cargando…

Clinical Ocular Diagnostic Model of Marfan Syndrome in Patients With Congenital Ectopia Lentis by Pentacam AXL System

PURPOSE: To construct an ocular diagnostic model of Marfan syndrome (MFS) distinguishing MFS from congenital ectopia lentis by the Pentacam AXL system. METHODS: Multivariable logistic regression was performed for the MFS ocular model. Furthermore, discrimination and calibration were validated extern...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Tianhui, Chen, Jiahui, Jin, Guangming, Zhang, Min, Chen, Zexu, Zheng, Danying, Jiang, Yongxiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8185401/
https://www.ncbi.nlm.nih.gov/pubmed/34061947
http://dx.doi.org/10.1167/tvst.10.7.3
_version_ 1783704780809437184
author Chen, Tianhui
Chen, Jiahui
Jin, Guangming
Zhang, Min
Chen, Zexu
Zheng, Danying
Jiang, Yongxiang
author_facet Chen, Tianhui
Chen, Jiahui
Jin, Guangming
Zhang, Min
Chen, Zexu
Zheng, Danying
Jiang, Yongxiang
author_sort Chen, Tianhui
collection PubMed
description PURPOSE: To construct an ocular diagnostic model of Marfan syndrome (MFS) distinguishing MFS from congenital ectopia lentis by the Pentacam AXL system. METHODS: Multivariable logistic regression was performed for the MFS ocular model. Furthermore, discrimination and calibration were validated externally. Data for 96 patients with ectopia lentis were assigned to the training cohort. Eighty patients with ectopia lentis were assigned to the test cohort. Diagnosis of MFS was based on the Ghent-2 criteria and diagnosis of congenital ectopia lentis in the control did not comply with the Ghent-2 criteria. RESULTS: The clinical model was based on the axial length/total corneal refractive power ratio. In the training cohort, the area under the receiver operating characteristic curve was 0.816 (95% confidence interval, 0.754–0.878) in the final model, which showed better performance than the previous minor criteria for diagnosis MFS of myopia of more than 3 diopters. In the test cohort, the area under the receiver operating characteristic curve was 0.818 (95% confidence interval, 0.718–0.918). In decision curve analysis, the net benefit of the model was better between threshold probabilities of 40% to 80%. CONCLUSIONS: We demonstrated the value of the axial length/total corneal refractive power ratio as a potential diagnostic marker of MFS and clinical performance of diagnostic models, which may assist ophthalmologists in rapid identification of the patients at high risk of MFS. TRANSLATIONAL RELEVANCE: This clinical ocular diagnostic model can be easily applied using the Pentacam AXL system. This model aids in the early differential diagnosis of MFS from other forms of congenital ectopia lentis, which may decrease the risk of developing severe ocular symptoms.
format Online
Article
Text
id pubmed-8185401
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-81854012021-06-16 Clinical Ocular Diagnostic Model of Marfan Syndrome in Patients With Congenital Ectopia Lentis by Pentacam AXL System Chen, Tianhui Chen, Jiahui Jin, Guangming Zhang, Min Chen, Zexu Zheng, Danying Jiang, Yongxiang Transl Vis Sci Technol Article PURPOSE: To construct an ocular diagnostic model of Marfan syndrome (MFS) distinguishing MFS from congenital ectopia lentis by the Pentacam AXL system. METHODS: Multivariable logistic regression was performed for the MFS ocular model. Furthermore, discrimination and calibration were validated externally. Data for 96 patients with ectopia lentis were assigned to the training cohort. Eighty patients with ectopia lentis were assigned to the test cohort. Diagnosis of MFS was based on the Ghent-2 criteria and diagnosis of congenital ectopia lentis in the control did not comply with the Ghent-2 criteria. RESULTS: The clinical model was based on the axial length/total corneal refractive power ratio. In the training cohort, the area under the receiver operating characteristic curve was 0.816 (95% confidence interval, 0.754–0.878) in the final model, which showed better performance than the previous minor criteria for diagnosis MFS of myopia of more than 3 diopters. In the test cohort, the area under the receiver operating characteristic curve was 0.818 (95% confidence interval, 0.718–0.918). In decision curve analysis, the net benefit of the model was better between threshold probabilities of 40% to 80%. CONCLUSIONS: We demonstrated the value of the axial length/total corneal refractive power ratio as a potential diagnostic marker of MFS and clinical performance of diagnostic models, which may assist ophthalmologists in rapid identification of the patients at high risk of MFS. TRANSLATIONAL RELEVANCE: This clinical ocular diagnostic model can be easily applied using the Pentacam AXL system. This model aids in the early differential diagnosis of MFS from other forms of congenital ectopia lentis, which may decrease the risk of developing severe ocular symptoms. The Association for Research in Vision and Ophthalmology 2021-06-01 /pmc/articles/PMC8185401/ /pubmed/34061947 http://dx.doi.org/10.1167/tvst.10.7.3 Text en Copyright 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Chen, Tianhui
Chen, Jiahui
Jin, Guangming
Zhang, Min
Chen, Zexu
Zheng, Danying
Jiang, Yongxiang
Clinical Ocular Diagnostic Model of Marfan Syndrome in Patients With Congenital Ectopia Lentis by Pentacam AXL System
title Clinical Ocular Diagnostic Model of Marfan Syndrome in Patients With Congenital Ectopia Lentis by Pentacam AXL System
title_full Clinical Ocular Diagnostic Model of Marfan Syndrome in Patients With Congenital Ectopia Lentis by Pentacam AXL System
title_fullStr Clinical Ocular Diagnostic Model of Marfan Syndrome in Patients With Congenital Ectopia Lentis by Pentacam AXL System
title_full_unstemmed Clinical Ocular Diagnostic Model of Marfan Syndrome in Patients With Congenital Ectopia Lentis by Pentacam AXL System
title_short Clinical Ocular Diagnostic Model of Marfan Syndrome in Patients With Congenital Ectopia Lentis by Pentacam AXL System
title_sort clinical ocular diagnostic model of marfan syndrome in patients with congenital ectopia lentis by pentacam axl system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8185401/
https://www.ncbi.nlm.nih.gov/pubmed/34061947
http://dx.doi.org/10.1167/tvst.10.7.3
work_keys_str_mv AT chentianhui clinicaloculardiagnosticmodelofmarfansyndromeinpatientswithcongenitalectopialentisbypentacamaxlsystem
AT chenjiahui clinicaloculardiagnosticmodelofmarfansyndromeinpatientswithcongenitalectopialentisbypentacamaxlsystem
AT jinguangming clinicaloculardiagnosticmodelofmarfansyndromeinpatientswithcongenitalectopialentisbypentacamaxlsystem
AT zhangmin clinicaloculardiagnosticmodelofmarfansyndromeinpatientswithcongenitalectopialentisbypentacamaxlsystem
AT chenzexu clinicaloculardiagnosticmodelofmarfansyndromeinpatientswithcongenitalectopialentisbypentacamaxlsystem
AT zhengdanying clinicaloculardiagnosticmodelofmarfansyndromeinpatientswithcongenitalectopialentisbypentacamaxlsystem
AT jiangyongxiang clinicaloculardiagnosticmodelofmarfansyndromeinpatientswithcongenitalectopialentisbypentacamaxlsystem