Cargando…

Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation

Tibial plateau fractures occur in both old and young patients and may be caused by low-energy trauma, as well as high-energy trauma. Owing to the variety of injury mechanisms and fracture patterns, tibial plateau fractures are very challenging to treat. One of the most demanding fractures is the typ...

Descripción completa

Detalles Bibliográficos
Autores principales: Hermanowicz, Krzysztof, Mrozek, Tomasz, Góralczyk, Adrian, Malinowski, Konrad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8185522/
https://www.ncbi.nlm.nih.gov/pubmed/34141531
http://dx.doi.org/10.1016/j.eats.2021.01.014
_version_ 1783704805889277952
author Hermanowicz, Krzysztof
Mrozek, Tomasz
Góralczyk, Adrian
Malinowski, Konrad
author_facet Hermanowicz, Krzysztof
Mrozek, Tomasz
Góralczyk, Adrian
Malinowski, Konrad
author_sort Hermanowicz, Krzysztof
collection PubMed
description Tibial plateau fractures occur in both old and young patients and may be caused by low-energy trauma, as well as high-energy trauma. Owing to the variety of injury mechanisms and fracture patterns, tibial plateau fractures are very challenging to treat. One of the most demanding fractures is the type III fracture according to the Schatzker classification, which is a pure depression of the lateral tibial plateau. Treatment with open surgical procedures is associated with vast soft-tissue trauma and prolonged recovery after surgery. Although soft-tissue trauma is minimized and visual control is improved throughout arthroscopy-assisted surgical procedures, internal fixation using buttress plates or lag screws is still required to reduce and fix the depressed plateau. We present an arthroscopy-assisted technique of reduction and fixation of the lateral tibial plateau fracture with 3 BioComposite interference screws (Arthrex, Munich, Germany) that provides a high amount of stability and reduces patient immobilization, allowing for faster rehabilitation.
format Online
Article
Text
id pubmed-8185522
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-81855222021-06-16 Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation Hermanowicz, Krzysztof Mrozek, Tomasz Góralczyk, Adrian Malinowski, Konrad Arthrosc Tech Technical Note Tibial plateau fractures occur in both old and young patients and may be caused by low-energy trauma, as well as high-energy trauma. Owing to the variety of injury mechanisms and fracture patterns, tibial plateau fractures are very challenging to treat. One of the most demanding fractures is the type III fracture according to the Schatzker classification, which is a pure depression of the lateral tibial plateau. Treatment with open surgical procedures is associated with vast soft-tissue trauma and prolonged recovery after surgery. Although soft-tissue trauma is minimized and visual control is improved throughout arthroscopy-assisted surgical procedures, internal fixation using buttress plates or lag screws is still required to reduce and fix the depressed plateau. We present an arthroscopy-assisted technique of reduction and fixation of the lateral tibial plateau fracture with 3 BioComposite interference screws (Arthrex, Munich, Germany) that provides a high amount of stability and reduces patient immobilization, allowing for faster rehabilitation. Elsevier 2021-04-03 /pmc/articles/PMC8185522/ /pubmed/34141531 http://dx.doi.org/10.1016/j.eats.2021.01.014 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Technical Note
Hermanowicz, Krzysztof
Mrozek, Tomasz
Góralczyk, Adrian
Malinowski, Konrad
Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation
title Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation
title_full Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation
title_fullStr Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation
title_full_unstemmed Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation
title_short Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation
title_sort arthroscopy-assisted management of schatzker type iii lateral tibial plateau fracture with interference screw fixation
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8185522/
https://www.ncbi.nlm.nih.gov/pubmed/34141531
http://dx.doi.org/10.1016/j.eats.2021.01.014
work_keys_str_mv AT hermanowiczkrzysztof arthroscopyassistedmanagementofschatzkertypeiiilateraltibialplateaufracturewithinterferencescrewfixation
AT mrozektomasz arthroscopyassistedmanagementofschatzkertypeiiilateraltibialplateaufracturewithinterferencescrewfixation
AT goralczykadrian arthroscopyassistedmanagementofschatzkertypeiiilateraltibialplateaufracturewithinterferencescrewfixation
AT malinowskikonrad arthroscopyassistedmanagementofschatzkertypeiiilateraltibialplateaufracturewithinterferencescrewfixation