Cargando…
Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported
BACKGROUND: CORKNOT® facilitates a reduction in cardiopulmonary bypass (CPB) time, aortic cross clamp (ACC) time and operative time, but reported to be associated with other complications. We aim to quantify the incidence of valvular complications related to CORKNOT® and determine the feasibility of...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8186203/ https://www.ncbi.nlm.nih.gov/pubmed/34099017 http://dx.doi.org/10.1186/s13019-021-01512-z |
_version_ | 1783704914208227328 |
---|---|
author | Sazzad, Faizus Xian, Ong Zhi Ler, Ashlynn Guohao, Chang Swee, Kang Giap Kofidis, Theo |
author_facet | Sazzad, Faizus Xian, Ong Zhi Ler, Ashlynn Guohao, Chang Swee, Kang Giap Kofidis, Theo |
author_sort | Sazzad, Faizus |
collection | PubMed |
description | BACKGROUND: CORKNOT® facilitates a reduction in cardiopulmonary bypass (CPB) time, aortic cross clamp (ACC) time and operative time, but reported to be associated with other complications. We aim to quantify the incidence of valvular complications related to CORKNOT® and determine the feasibility of its use between different valvular surgeries. METHODS: Patients who underwent heart valve repair or replacement surgery via the use of automated titanium suture fasteners (CORKNOT®) in a tertiary care hospital were included in the study. This single-centre retrospective study was conducted on 132 patients between January 2016 and June 2018. RESULTS: In our study, the overall mean operative time was 320.0 ± 97.0 min, mean CPB time was 171.4 ± 76.0 min and the calculated mean ACC time was 105.9 ± 54.0 min. Fifty-eight patients (43.9%) underwent minimally invasive valve replacement or repair surgery and 66 patients (50.0%) underwent concomitant procedures. A total of 157 valves were operated on, with 112 (84.8%) single valve surgeries, 15 (11.4%) double valve surgeries and 5 (3.8%) triple valve surgeries. After reviewed by the cardiologist blinded towards the study, we report trivial and/or mild paravalvular leak (PVL) in immediate post-operative echocardiography was found in 1 (1.01%) patients. There were no reported cases of valvular thrombosis, leaflet perforation, device dislodgement or embolization, moderate and/or severe PVL during hospitalization and follow-up echocardiography within 1 year. Single mitral valve and aortic surgeries had comparable incidences of post surgical complications. CONCLUSION: We conclude the feasibility of CORKNOT® utilisation in mitral and aortic valve surgeries. Additionally, incidence of CORKNOT® related complications in heart valve repair or replacement surgery is less usual in our setting than previously reported. These results motivate the use of CORKNOT® as a valid alternative with complete commitment. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13019-021-01512-z. |
format | Online Article Text |
id | pubmed-8186203 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-81862032021-06-10 Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported Sazzad, Faizus Xian, Ong Zhi Ler, Ashlynn Guohao, Chang Swee, Kang Giap Kofidis, Theo J Cardiothorac Surg Research Article BACKGROUND: CORKNOT® facilitates a reduction in cardiopulmonary bypass (CPB) time, aortic cross clamp (ACC) time and operative time, but reported to be associated with other complications. We aim to quantify the incidence of valvular complications related to CORKNOT® and determine the feasibility of its use between different valvular surgeries. METHODS: Patients who underwent heart valve repair or replacement surgery via the use of automated titanium suture fasteners (CORKNOT®) in a tertiary care hospital were included in the study. This single-centre retrospective study was conducted on 132 patients between January 2016 and June 2018. RESULTS: In our study, the overall mean operative time was 320.0 ± 97.0 min, mean CPB time was 171.4 ± 76.0 min and the calculated mean ACC time was 105.9 ± 54.0 min. Fifty-eight patients (43.9%) underwent minimally invasive valve replacement or repair surgery and 66 patients (50.0%) underwent concomitant procedures. A total of 157 valves were operated on, with 112 (84.8%) single valve surgeries, 15 (11.4%) double valve surgeries and 5 (3.8%) triple valve surgeries. After reviewed by the cardiologist blinded towards the study, we report trivial and/or mild paravalvular leak (PVL) in immediate post-operative echocardiography was found in 1 (1.01%) patients. There were no reported cases of valvular thrombosis, leaflet perforation, device dislodgement or embolization, moderate and/or severe PVL during hospitalization and follow-up echocardiography within 1 year. Single mitral valve and aortic surgeries had comparable incidences of post surgical complications. CONCLUSION: We conclude the feasibility of CORKNOT® utilisation in mitral and aortic valve surgeries. Additionally, incidence of CORKNOT® related complications in heart valve repair or replacement surgery is less usual in our setting than previously reported. These results motivate the use of CORKNOT® as a valid alternative with complete commitment. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13019-021-01512-z. BioMed Central 2021-06-07 /pmc/articles/PMC8186203/ /pubmed/34099017 http://dx.doi.org/10.1186/s13019-021-01512-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Sazzad, Faizus Xian, Ong Zhi Ler, Ashlynn Guohao, Chang Swee, Kang Giap Kofidis, Theo Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported |
title | Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported |
title_full | Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported |
title_fullStr | Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported |
title_full_unstemmed | Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported |
title_short | Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported |
title_sort | incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (corknot®) in heart valve repair or replacement: less usual than reported |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8186203/ https://www.ncbi.nlm.nih.gov/pubmed/34099017 http://dx.doi.org/10.1186/s13019-021-01512-z |
work_keys_str_mv | AT sazzadfaizus incidenceofvalvularregurgitationandleafletperforationbyusingautomatedtitaniumfastenerscorknotinheartvalverepairorreplacementlessusualthanreported AT xianongzhi incidenceofvalvularregurgitationandleafletperforationbyusingautomatedtitaniumfastenerscorknotinheartvalverepairorreplacementlessusualthanreported AT lerashlynn incidenceofvalvularregurgitationandleafletperforationbyusingautomatedtitaniumfastenerscorknotinheartvalverepairorreplacementlessusualthanreported AT guohaochang incidenceofvalvularregurgitationandleafletperforationbyusingautomatedtitaniumfastenerscorknotinheartvalverepairorreplacementlessusualthanreported AT sweekanggiap incidenceofvalvularregurgitationandleafletperforationbyusingautomatedtitaniumfastenerscorknotinheartvalverepairorreplacementlessusualthanreported AT kofidistheo incidenceofvalvularregurgitationandleafletperforationbyusingautomatedtitaniumfastenerscorknotinheartvalverepairorreplacementlessusualthanreported |