Cargando…

Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma

PURPOSE: The aim of this study was to compare the diagnostic ability of macular ganglion cell layer (GCL) analysis using spectral domain optical coherence tomography against retinal nerve fiber layer analysis (RNFL), short-wavelength automated perimetry (SWAP), and standard automated perimetry (SAP)...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalyani, VKS, Bharucha, Khurshed M, Goyal, Nikhil, Deshpande, Madan M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8186634/
https://www.ncbi.nlm.nih.gov/pubmed/33913843
http://dx.doi.org/10.4103/ijo.IJO_2409_20
_version_ 1783704984917901312
author Kalyani, VKS
Bharucha, Khurshed M
Goyal, Nikhil
Deshpande, Madan M
author_facet Kalyani, VKS
Bharucha, Khurshed M
Goyal, Nikhil
Deshpande, Madan M
author_sort Kalyani, VKS
collection PubMed
description PURPOSE: The aim of this study was to compare the diagnostic ability of macular ganglion cell layer (GCL) analysis using spectral domain optical coherence tomography against retinal nerve fiber layer analysis (RNFL), short-wavelength automated perimetry (SWAP), and standard automated perimetry (SAP) in early detection of glaucoma. METHODS: Participants fulfilling the inclusion criteria were consecutively enrolled from the glaucoma clinic of tertiary care eye hospital in Western India from November 2015 to October 2016. The subjects underwent a detailed evaluation by trained glaucoma specialists. On suspicion of glaucoma, the patients underwent SAP, SWAP, and SD-OCT for GCL and RNFL analysis. RESULTS: There were 91 patients in total of which experts classified 54 eyes into GON and 37 eyes into nonglaucomatous group. Sensitivity of SAP (42.59%) was significantly lower (P < 0.05) than that of average GCL thickness (79.63%) and average RNFL thickness (72.22%). Specificity and positive LR of SWAP (97.3% and 19.19, respectively) and SAP (94.6% and 7.88, respectively) were greater than those of GCL (81.08% and 4.21) and RNFL (67.57% and 2.23) parameters. Negative LR of average GCL thickness (0.25) was superior to that of average RNFL thickness (0.411), SWAP (0.495), and SAP (0.607). CONCLUSION: Macular GCL parameters perform better than RNFL parameters in patients with early glaucomatous damage. There is superior ability of SWAP over SAP in detecting glaucomatous changes in glaucoma suspect group. GCL thickness analysis has higher sensitivity and negative likelihood ratio, whereas SWAP had higher specificity and positive likelihood ratio. Thus, combining both tests can lead to better diagnostic ability for early glaucomatous damage.
format Online
Article
Text
id pubmed-8186634
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-81866342021-06-10 Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma Kalyani, VKS Bharucha, Khurshed M Goyal, Nikhil Deshpande, Madan M Indian J Ophthalmol Original Article PURPOSE: The aim of this study was to compare the diagnostic ability of macular ganglion cell layer (GCL) analysis using spectral domain optical coherence tomography against retinal nerve fiber layer analysis (RNFL), short-wavelength automated perimetry (SWAP), and standard automated perimetry (SAP) in early detection of glaucoma. METHODS: Participants fulfilling the inclusion criteria were consecutively enrolled from the glaucoma clinic of tertiary care eye hospital in Western India from November 2015 to October 2016. The subjects underwent a detailed evaluation by trained glaucoma specialists. On suspicion of glaucoma, the patients underwent SAP, SWAP, and SD-OCT for GCL and RNFL analysis. RESULTS: There were 91 patients in total of which experts classified 54 eyes into GON and 37 eyes into nonglaucomatous group. Sensitivity of SAP (42.59%) was significantly lower (P < 0.05) than that of average GCL thickness (79.63%) and average RNFL thickness (72.22%). Specificity and positive LR of SWAP (97.3% and 19.19, respectively) and SAP (94.6% and 7.88, respectively) were greater than those of GCL (81.08% and 4.21) and RNFL (67.57% and 2.23) parameters. Negative LR of average GCL thickness (0.25) was superior to that of average RNFL thickness (0.411), SWAP (0.495), and SAP (0.607). CONCLUSION: Macular GCL parameters perform better than RNFL parameters in patients with early glaucomatous damage. There is superior ability of SWAP over SAP in detecting glaucomatous changes in glaucoma suspect group. GCL thickness analysis has higher sensitivity and negative likelihood ratio, whereas SWAP had higher specificity and positive likelihood ratio. Thus, combining both tests can lead to better diagnostic ability for early glaucomatous damage. Wolters Kluwer - Medknow 2021-05 2021-04-30 /pmc/articles/PMC8186634/ /pubmed/33913843 http://dx.doi.org/10.4103/ijo.IJO_2409_20 Text en Copyright: © 2021 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kalyani, VKS
Bharucha, Khurshed M
Goyal, Nikhil
Deshpande, Madan M
Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma
title Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma
title_full Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma
title_fullStr Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma
title_full_unstemmed Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma
title_short Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma
title_sort comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8186634/
https://www.ncbi.nlm.nih.gov/pubmed/33913843
http://dx.doi.org/10.4103/ijo.IJO_2409_20
work_keys_str_mv AT kalyanivks comparisonofdiagnosticabilityofstandardautomatedperimetryshortwavelengthautomatedperimetryretinalnervefiberlayerthicknessanalysisandganglioncelllayerthicknessanalysisinearlydetectionofglaucoma
AT bharuchakhurshedm comparisonofdiagnosticabilityofstandardautomatedperimetryshortwavelengthautomatedperimetryretinalnervefiberlayerthicknessanalysisandganglioncelllayerthicknessanalysisinearlydetectionofglaucoma
AT goyalnikhil comparisonofdiagnosticabilityofstandardautomatedperimetryshortwavelengthautomatedperimetryretinalnervefiberlayerthicknessanalysisandganglioncelllayerthicknessanalysisinearlydetectionofglaucoma
AT deshpandemadanm comparisonofdiagnosticabilityofstandardautomatedperimetryshortwavelengthautomatedperimetryretinalnervefiberlayerthicknessanalysisandganglioncelllayerthicknessanalysisinearlydetectionofglaucoma