Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients
INTRODUCTION: In this research, we used a volumetric absorptive microsampling (VAMS) technique to collect blood samples from the patients. A rapid and simple sample preparation method and LC-MS.MS assay was then developed and validated for the simultaneous analysis of tamoxifen and its three active...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8187001/ https://www.ncbi.nlm.nih.gov/pubmed/34113081 http://dx.doi.org/10.2147/DDDT.S286409 |
_version_ | 1783705056384647168 |
---|---|
author | Maggadani, Baitha Palanggatan Harmita, Haryono, Samuel J Rinaldi, Marcellino Ryan Harahap, Yahdiana |
author_facet | Maggadani, Baitha Palanggatan Harmita, Haryono, Samuel J Rinaldi, Marcellino Ryan Harahap, Yahdiana |
author_sort | Maggadani, Baitha Palanggatan |
collection | PubMed |
description | INTRODUCTION: In this research, we used a volumetric absorptive microsampling (VAMS) technique to collect blood samples from the patients. A rapid and simple sample preparation method and LC-MS.MS assay was then developed and validated for the simultaneous analysis of tamoxifen and its three active metabolites. METHODS: VAMS extraction was performed in methanol by sonication-assisted extraction method for 25 min after 2 hof VAMS drying. Separation was carried out using Acquity UPLC BEH C(18) column (2.1 x 100 mm; 1.7 µm), with a flow rate of 0.2 mL/min, and the mobile phase gradient of formic acid 0.1% and formic acid 0.1% in acetonitrile for 5 min. The multiple reaction monitoring (MRM) values were set at m/z 358.31>58.27 for N-desmethyltamoxifen, m/z 372.33>72.28 for tamoxifen, m/z 388.22>72.28 for 4-hydroxytamoxifen, m/z 374.25>58.25 for endoxifen, and m/z 260.26>116.12 for propranolol. RESULTS AND DISCUSSION: The lower limit of quantification value (LLOQ) was 2.50 ng/mL for tamoxifen, 2.50 ng/mL for endoxifen, 1.50 ng/mL for 4-hydroxitamoxifen, and 2.00 ng/mL for N-desmethyltamoxifen. Accuracy (%bias) and precision (%CV) were within 20% for LLOQ and 15% for other concentrations. There were no interference responses >20% of the LLOQ and 5% of the internal standard. The level of ion suppression in all analytes was less than 7%. The preparation system developed in this study successfully extracted more than 90% of analytes from the matrix with precision below 15%. Carryover was shown to be below 6% in all analytes. Stability of analytes in VAMS was demonstrated for up to 30 days, under room temperature storage in a sealed plastic bag with desiccant. This method was successfully applied to analyze tamoxifen and the metabolites level in 30 ER+ breast cancer patients. |
format | Online Article Text |
id | pubmed-8187001 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-81870012021-06-09 Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients Maggadani, Baitha Palanggatan Harmita, Haryono, Samuel J Rinaldi, Marcellino Ryan Harahap, Yahdiana Drug Des Devel Ther Original Research INTRODUCTION: In this research, we used a volumetric absorptive microsampling (VAMS) technique to collect blood samples from the patients. A rapid and simple sample preparation method and LC-MS.MS assay was then developed and validated for the simultaneous analysis of tamoxifen and its three active metabolites. METHODS: VAMS extraction was performed in methanol by sonication-assisted extraction method for 25 min after 2 hof VAMS drying. Separation was carried out using Acquity UPLC BEH C(18) column (2.1 x 100 mm; 1.7 µm), with a flow rate of 0.2 mL/min, and the mobile phase gradient of formic acid 0.1% and formic acid 0.1% in acetonitrile for 5 min. The multiple reaction monitoring (MRM) values were set at m/z 358.31>58.27 for N-desmethyltamoxifen, m/z 372.33>72.28 for tamoxifen, m/z 388.22>72.28 for 4-hydroxytamoxifen, m/z 374.25>58.25 for endoxifen, and m/z 260.26>116.12 for propranolol. RESULTS AND DISCUSSION: The lower limit of quantification value (LLOQ) was 2.50 ng/mL for tamoxifen, 2.50 ng/mL for endoxifen, 1.50 ng/mL for 4-hydroxitamoxifen, and 2.00 ng/mL for N-desmethyltamoxifen. Accuracy (%bias) and precision (%CV) were within 20% for LLOQ and 15% for other concentrations. There were no interference responses >20% of the LLOQ and 5% of the internal standard. The level of ion suppression in all analytes was less than 7%. The preparation system developed in this study successfully extracted more than 90% of analytes from the matrix with precision below 15%. Carryover was shown to be below 6% in all analytes. Stability of analytes in VAMS was demonstrated for up to 30 days, under room temperature storage in a sealed plastic bag with desiccant. This method was successfully applied to analyze tamoxifen and the metabolites level in 30 ER+ breast cancer patients. Dove 2021-06-04 /pmc/articles/PMC8187001/ /pubmed/34113081 http://dx.doi.org/10.2147/DDDT.S286409 Text en © 2021 Maggadani et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Maggadani, Baitha Palanggatan Harmita, Haryono, Samuel J Rinaldi, Marcellino Ryan Harahap, Yahdiana Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients |
title | Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients |
title_full | Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients |
title_fullStr | Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients |
title_full_unstemmed | Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients |
title_short | Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients |
title_sort | volumetric absorptive microsampling as a new biosampling tool for monitoring of tamoxifen, endoxifen, 4-oh tamoxifen and n-desmethyltamoxifen in breast cancer patients |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8187001/ https://www.ncbi.nlm.nih.gov/pubmed/34113081 http://dx.doi.org/10.2147/DDDT.S286409 |
work_keys_str_mv | AT maggadanibaithapalanggatan volumetricabsorptivemicrosamplingasanewbiosamplingtoolformonitoringoftamoxifenendoxifen4ohtamoxifenandndesmethyltamoxifeninbreastcancerpatients AT harmita volumetricabsorptivemicrosamplingasanewbiosamplingtoolformonitoringoftamoxifenendoxifen4ohtamoxifenandndesmethyltamoxifeninbreastcancerpatients AT haryonosamuelj volumetricabsorptivemicrosamplingasanewbiosamplingtoolformonitoringoftamoxifenendoxifen4ohtamoxifenandndesmethyltamoxifeninbreastcancerpatients AT rinaldimarcellinoryan volumetricabsorptivemicrosamplingasanewbiosamplingtoolformonitoringoftamoxifenendoxifen4ohtamoxifenandndesmethyltamoxifeninbreastcancerpatients AT harahapyahdiana volumetricabsorptivemicrosamplingasanewbiosamplingtoolformonitoringoftamoxifenendoxifen4ohtamoxifenandndesmethyltamoxifeninbreastcancerpatients |