Monte-Carlo-Simulation biometrischer Effektgrößen und deren Einfluss auf das Übersetzungsverhältnis des Hornhautastigmatismus in den Zylinder torischer Intraokularlinsen

BACKGROUND AND OBJECTIVE: Toric intraocular lenses (IOL) provide a reliable and predictable option for permanent correction of corneal astigmatism. In order to determine the lens strength necessary for achieving the desired correction, the operator can either use the calculation mode implemented in...

Descripción completa

Detalles Bibliográficos
Autores principales: Langenbucher, Achim, Schrecker, Jens, Schwemm, Michael, Eppig, Timo, Schröder, S., Szentmáry, Nóra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Medizin 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8187219/
https://www.ncbi.nlm.nih.gov/pubmed/32767100
http://dx.doi.org/10.1007/s00347-020-01199-y
_version_ 1783705099734876160
author Langenbucher, Achim
Schrecker, Jens
Schwemm, Michael
Eppig, Timo
Schröder, S.
Szentmáry, Nóra
author_facet Langenbucher, Achim
Schrecker, Jens
Schwemm, Michael
Eppig, Timo
Schröder, S.
Szentmáry, Nóra
author_sort Langenbucher, Achim
collection PubMed
description BACKGROUND AND OBJECTIVE: Toric intraocular lenses (IOL) provide a reliable and predictable option for permanent correction of corneal astigmatism. In order to determine the lens strength necessary for achieving the desired correction, the operator can either use the calculation mode implemented in the biometry device or the calculation service offered by the lens manufacturer; however, in many cases a classical lens calculation from biometric data is not carried out but only a simplified estimation, which translates the corneal astigmatism into the torus of the toric IOL. This translational ratio, which is mostly used as an average standard value, can however show a substantial range of variation, so that in a worst case scenario an undercorrection of the refractive cylinder of up to 12.5 % or an overcorrection of up to 17 % can result. The purpose of this study was to elaborate the biometric effect sizes which determine the relationship between the corneal astigmatism to be corrected and the torus necessary for a full correction of an IOL. METHODS: A total of 16,744 datasets were extracted from the IOLCon web platform and initially the axial position of the IOL implant was derived independent of a formula, based on the preoperative biometric values and the postoperative spherical equivalent. Subsequently, based on a ray propagation strategy for spherocylindrical vergences, the corresponding refractive value of a full correcting toric IOL was calculated. The translational relationship as a ratio between lens toricity and corneal astigmatism was analyzed for potential biometric effect sizes with a Monte Carlo simulation. RESULTS: The Monte Carlo simulation showed that the ratio of lens toricity to corneal astigmatism cannot be assumed as being constant. The analyzed data revealed an average translational ratio of 1.3938 ± 0.0595 (median 1.3921) with a range from 1.2131 to 1.5974. The axial position of the IOL was found to have the greatest influence, whereby the more posterior the lens position the higher the ratio. Due to the correlation of axial eye length and axial lens position, the eye length can be assumed to be an indirect effect size. The corneal equivalent refractive strength and the corneal astigmatism have no noteworthy effect on the translational ratio. CONCLUSION: Many calculation tools on the market simplify toric IOL power calculation by assuming a constant ratio of lens toricity to corneal astigmatism; however, the present simulation study showed that such a simplification can lead to clearly incorrect results. Accordingly, an individual calculation of IOL toricity based on biometric parameters (e.g. based on vergence propagation matrices or full aperture ray tracing) is recommended.
format Online
Article
Text
id pubmed-8187219
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Medizin
record_format MEDLINE/PubMed
spelling pubmed-81872192021-06-11 Monte-Carlo-Simulation biometrischer Effektgrößen und deren Einfluss auf das Übersetzungsverhältnis des Hornhautastigmatismus in den Zylinder torischer Intraokularlinsen Langenbucher, Achim Schrecker, Jens Schwemm, Michael Eppig, Timo Schröder, S. Szentmáry, Nóra Ophthalmologe Originalien BACKGROUND AND OBJECTIVE: Toric intraocular lenses (IOL) provide a reliable and predictable option for permanent correction of corneal astigmatism. In order to determine the lens strength necessary for achieving the desired correction, the operator can either use the calculation mode implemented in the biometry device or the calculation service offered by the lens manufacturer; however, in many cases a classical lens calculation from biometric data is not carried out but only a simplified estimation, which translates the corneal astigmatism into the torus of the toric IOL. This translational ratio, which is mostly used as an average standard value, can however show a substantial range of variation, so that in a worst case scenario an undercorrection of the refractive cylinder of up to 12.5 % or an overcorrection of up to 17 % can result. The purpose of this study was to elaborate the biometric effect sizes which determine the relationship between the corneal astigmatism to be corrected and the torus necessary for a full correction of an IOL. METHODS: A total of 16,744 datasets were extracted from the IOLCon web platform and initially the axial position of the IOL implant was derived independent of a formula, based on the preoperative biometric values and the postoperative spherical equivalent. Subsequently, based on a ray propagation strategy for spherocylindrical vergences, the corresponding refractive value of a full correcting toric IOL was calculated. The translational relationship as a ratio between lens toricity and corneal astigmatism was analyzed for potential biometric effect sizes with a Monte Carlo simulation. RESULTS: The Monte Carlo simulation showed that the ratio of lens toricity to corneal astigmatism cannot be assumed as being constant. The analyzed data revealed an average translational ratio of 1.3938 ± 0.0595 (median 1.3921) with a range from 1.2131 to 1.5974. The axial position of the IOL was found to have the greatest influence, whereby the more posterior the lens position the higher the ratio. Due to the correlation of axial eye length and axial lens position, the eye length can be assumed to be an indirect effect size. The corneal equivalent refractive strength and the corneal astigmatism have no noteworthy effect on the translational ratio. CONCLUSION: Many calculation tools on the market simplify toric IOL power calculation by assuming a constant ratio of lens toricity to corneal astigmatism; however, the present simulation study showed that such a simplification can lead to clearly incorrect results. Accordingly, an individual calculation of IOL toricity based on biometric parameters (e.g. based on vergence propagation matrices or full aperture ray tracing) is recommended. Springer Medizin 2020-08-07 2021 /pmc/articles/PMC8187219/ /pubmed/32767100 http://dx.doi.org/10.1007/s00347-020-01199-y Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open Access. Dieser Artikel wird unter der Creative Commons Namensnennung 4.0 International Lizenz veröffentlicht, welche die Nutzung, Vervielfältigung, Bearbeitung, Verbreitung und Wiedergabe in jeglichem Medium und Format erlaubt, sofern Sie den/die ursprünglichen Autor(en) und die Quelle ordnungsgemäß nennen, einen Link zur Creative Commons Lizenz beifügen und angeben, ob Änderungen vorgenommen wurden. Die in diesem Artikel enthaltenen Bilder und sonstiges Drittmaterial unterliegen ebenfalls der genannten Creative Commons Lizenz, sofern sich aus der Abbildungslegende nichts anderes ergibt. Sofern das betreffende Material nicht unter der genannten Creative Commons Lizenz steht und die betreffende Handlung nicht nach gesetzlichen Vorschriften erlaubt ist, ist für die oben aufgeführten Weiterverwendungen des Materials die Einwilligung des jeweiligen Rechteinhabers einzuholen. Weitere Details zur Lizenz entnehmen Sie bitte der Lizenzinformation auf http://creativecommons.org/licenses/by/4.0/deed.de (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Originalien
Langenbucher, Achim
Schrecker, Jens
Schwemm, Michael
Eppig, Timo
Schröder, S.
Szentmáry, Nóra
Monte-Carlo-Simulation biometrischer Effektgrößen und deren Einfluss auf das Übersetzungsverhältnis des Hornhautastigmatismus in den Zylinder torischer Intraokularlinsen
title Monte-Carlo-Simulation biometrischer Effektgrößen und deren Einfluss auf das Übersetzungsverhältnis des Hornhautastigmatismus in den Zylinder torischer Intraokularlinsen
title_full Monte-Carlo-Simulation biometrischer Effektgrößen und deren Einfluss auf das Übersetzungsverhältnis des Hornhautastigmatismus in den Zylinder torischer Intraokularlinsen
title_fullStr Monte-Carlo-Simulation biometrischer Effektgrößen und deren Einfluss auf das Übersetzungsverhältnis des Hornhautastigmatismus in den Zylinder torischer Intraokularlinsen
title_full_unstemmed Monte-Carlo-Simulation biometrischer Effektgrößen und deren Einfluss auf das Übersetzungsverhältnis des Hornhautastigmatismus in den Zylinder torischer Intraokularlinsen
title_short Monte-Carlo-Simulation biometrischer Effektgrößen und deren Einfluss auf das Übersetzungsverhältnis des Hornhautastigmatismus in den Zylinder torischer Intraokularlinsen
title_sort monte-carlo-simulation biometrischer effektgrößen und deren einfluss auf das übersetzungsverhältnis des hornhautastigmatismus in den zylinder torischer intraokularlinsen
topic Originalien
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8187219/
https://www.ncbi.nlm.nih.gov/pubmed/32767100
http://dx.doi.org/10.1007/s00347-020-01199-y
work_keys_str_mv AT langenbucherachim montecarlosimulationbiometrischereffektgroßenunddereneinflussaufdasubersetzungsverhaltnisdeshornhautastigmatismusindenzylindertorischerintraokularlinsen
AT schreckerjens montecarlosimulationbiometrischereffektgroßenunddereneinflussaufdasubersetzungsverhaltnisdeshornhautastigmatismusindenzylindertorischerintraokularlinsen
AT schwemmmichael montecarlosimulationbiometrischereffektgroßenunddereneinflussaufdasubersetzungsverhaltnisdeshornhautastigmatismusindenzylindertorischerintraokularlinsen
AT eppigtimo montecarlosimulationbiometrischereffektgroßenunddereneinflussaufdasubersetzungsverhaltnisdeshornhautastigmatismusindenzylindertorischerintraokularlinsen
AT schroders montecarlosimulationbiometrischereffektgroßenunddereneinflussaufdasubersetzungsverhaltnisdeshornhautastigmatismusindenzylindertorischerintraokularlinsen
AT szentmarynora montecarlosimulationbiometrischereffektgroßenunddereneinflussaufdasubersetzungsverhaltnisdeshornhautastigmatismusindenzylindertorischerintraokularlinsen