Cargando…
Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity
BACKGROUND: Activity monitoring devices may be used to facilitate goal-setting, self-monitoring, and feedback towards a step-based physical activity (PA) goal. This study examined the performance of the wrist-worn Fitbit Charge 3™ (FC3) and sought opinions on walking and stepping-in-place from women...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8188700/ https://www.ncbi.nlm.nih.gov/pubmed/34103002 http://dx.doi.org/10.1186/s12884-021-03900-8 |
Sumario: | BACKGROUND: Activity monitoring devices may be used to facilitate goal-setting, self-monitoring, and feedback towards a step-based physical activity (PA) goal. This study examined the performance of the wrist-worn Fitbit Charge 3™ (FC3) and sought opinions on walking and stepping-in-place from women with gestational diabetes (GDM). METHODS: Participants completed six 2-min metronome-assisted over ground bouts that varied by cadence (67, 84, or 100 steps per minute) and mode (walking or stepping-in-place; N = 15), with the sequence randomized. Steps were estimated by FC3 and measured, in duplicate, by direct observation (hand-tally device, criterion). Equivalence testing by the two one-sided tests (TOST) method assessed agreement within ± 15%. Mean absolute percent error (MAPE) of steps were compared to 10%, the accuracy standard of the Consumer Technology Association (CTA)™. A subset (n = 10) completed a timed, 200-m self-paced walk to assess natural walking pace and cadence. All participants completed semi-structured interviews, which were transcribed and analyzed using descriptive and interpretive coding. RESULTS: Mean age was 27.0 years (SD 4.2), prepregnancy BMI 29.4 kg/m(2) (8.3), and gestational age 32.8 weeks (SD 2.6). The FC3 was equivalent to hand-tally for bouts of metronome-assisted walking and stepping-in-place at 84 and 100 steps per minute (i.e., P < .05), although walking at 100 steps per minute (P = .01) was no longer equivalent upon adjustment for multiple comparisons (i.e., at P < .007). The FC3 was equivalent to hand-tally during the 200-m walk (i.e., P < .001), in which mean pace was 68.2 m per minute (SD 10.7), or 2.5 miles per hour, and mean cadence 108.5 steps per minute (SD 6.5). For walking at 84 and 100 steps per minute, stepping-in-place at 100 steps per minute, and the 200-m walk, MAPE was within 10%, the accuracy standard of the CTA™. Interviews revealed motivation for PA, that stepping-in-place was an acceptable alternative to walking, and competing responsibilities made it difficult to find time for PA. CONCLUSIONS: The FC3 appears to be a valid step counter during the third trimester, particularly when walking or stepping-in-place at or close to women’s preferred cadence. |
---|