Cargando…
Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity
BACKGROUND: Activity monitoring devices may be used to facilitate goal-setting, self-monitoring, and feedback towards a step-based physical activity (PA) goal. This study examined the performance of the wrist-worn Fitbit Charge 3™ (FC3) and sought opinions on walking and stepping-in-place from women...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8188700/ https://www.ncbi.nlm.nih.gov/pubmed/34103002 http://dx.doi.org/10.1186/s12884-021-03900-8 |
_version_ | 1783705378191572992 |
---|---|
author | Ehrlich, Samantha F. Maples, Jill M. Barroso, Cristina S. Brown, Kathleen C. Bassett, David R. Zite, Nikki B. Fortner, Kimberly B. |
author_facet | Ehrlich, Samantha F. Maples, Jill M. Barroso, Cristina S. Brown, Kathleen C. Bassett, David R. Zite, Nikki B. Fortner, Kimberly B. |
author_sort | Ehrlich, Samantha F. |
collection | PubMed |
description | BACKGROUND: Activity monitoring devices may be used to facilitate goal-setting, self-monitoring, and feedback towards a step-based physical activity (PA) goal. This study examined the performance of the wrist-worn Fitbit Charge 3™ (FC3) and sought opinions on walking and stepping-in-place from women with gestational diabetes (GDM). METHODS: Participants completed six 2-min metronome-assisted over ground bouts that varied by cadence (67, 84, or 100 steps per minute) and mode (walking or stepping-in-place; N = 15), with the sequence randomized. Steps were estimated by FC3 and measured, in duplicate, by direct observation (hand-tally device, criterion). Equivalence testing by the two one-sided tests (TOST) method assessed agreement within ± 15%. Mean absolute percent error (MAPE) of steps were compared to 10%, the accuracy standard of the Consumer Technology Association (CTA)™. A subset (n = 10) completed a timed, 200-m self-paced walk to assess natural walking pace and cadence. All participants completed semi-structured interviews, which were transcribed and analyzed using descriptive and interpretive coding. RESULTS: Mean age was 27.0 years (SD 4.2), prepregnancy BMI 29.4 kg/m(2) (8.3), and gestational age 32.8 weeks (SD 2.6). The FC3 was equivalent to hand-tally for bouts of metronome-assisted walking and stepping-in-place at 84 and 100 steps per minute (i.e., P < .05), although walking at 100 steps per minute (P = .01) was no longer equivalent upon adjustment for multiple comparisons (i.e., at P < .007). The FC3 was equivalent to hand-tally during the 200-m walk (i.e., P < .001), in which mean pace was 68.2 m per minute (SD 10.7), or 2.5 miles per hour, and mean cadence 108.5 steps per minute (SD 6.5). For walking at 84 and 100 steps per minute, stepping-in-place at 100 steps per minute, and the 200-m walk, MAPE was within 10%, the accuracy standard of the CTA™. Interviews revealed motivation for PA, that stepping-in-place was an acceptable alternative to walking, and competing responsibilities made it difficult to find time for PA. CONCLUSIONS: The FC3 appears to be a valid step counter during the third trimester, particularly when walking or stepping-in-place at or close to women’s preferred cadence. |
format | Online Article Text |
id | pubmed-8188700 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-81887002021-06-10 Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity Ehrlich, Samantha F. Maples, Jill M. Barroso, Cristina S. Brown, Kathleen C. Bassett, David R. Zite, Nikki B. Fortner, Kimberly B. BMC Pregnancy Childbirth Research BACKGROUND: Activity monitoring devices may be used to facilitate goal-setting, self-monitoring, and feedback towards a step-based physical activity (PA) goal. This study examined the performance of the wrist-worn Fitbit Charge 3™ (FC3) and sought opinions on walking and stepping-in-place from women with gestational diabetes (GDM). METHODS: Participants completed six 2-min metronome-assisted over ground bouts that varied by cadence (67, 84, or 100 steps per minute) and mode (walking or stepping-in-place; N = 15), with the sequence randomized. Steps were estimated by FC3 and measured, in duplicate, by direct observation (hand-tally device, criterion). Equivalence testing by the two one-sided tests (TOST) method assessed agreement within ± 15%. Mean absolute percent error (MAPE) of steps were compared to 10%, the accuracy standard of the Consumer Technology Association (CTA)™. A subset (n = 10) completed a timed, 200-m self-paced walk to assess natural walking pace and cadence. All participants completed semi-structured interviews, which were transcribed and analyzed using descriptive and interpretive coding. RESULTS: Mean age was 27.0 years (SD 4.2), prepregnancy BMI 29.4 kg/m(2) (8.3), and gestational age 32.8 weeks (SD 2.6). The FC3 was equivalent to hand-tally for bouts of metronome-assisted walking and stepping-in-place at 84 and 100 steps per minute (i.e., P < .05), although walking at 100 steps per minute (P = .01) was no longer equivalent upon adjustment for multiple comparisons (i.e., at P < .007). The FC3 was equivalent to hand-tally during the 200-m walk (i.e., P < .001), in which mean pace was 68.2 m per minute (SD 10.7), or 2.5 miles per hour, and mean cadence 108.5 steps per minute (SD 6.5). For walking at 84 and 100 steps per minute, stepping-in-place at 100 steps per minute, and the 200-m walk, MAPE was within 10%, the accuracy standard of the CTA™. Interviews revealed motivation for PA, that stepping-in-place was an acceptable alternative to walking, and competing responsibilities made it difficult to find time for PA. CONCLUSIONS: The FC3 appears to be a valid step counter during the third trimester, particularly when walking or stepping-in-place at or close to women’s preferred cadence. BioMed Central 2021-06-08 /pmc/articles/PMC8188700/ /pubmed/34103002 http://dx.doi.org/10.1186/s12884-021-03900-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ehrlich, Samantha F. Maples, Jill M. Barroso, Cristina S. Brown, Kathleen C. Bassett, David R. Zite, Nikki B. Fortner, Kimberly B. Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity |
title | Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity |
title_full | Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity |
title_fullStr | Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity |
title_full_unstemmed | Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity |
title_short | Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity |
title_sort | using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8188700/ https://www.ncbi.nlm.nih.gov/pubmed/34103002 http://dx.doi.org/10.1186/s12884-021-03900-8 |
work_keys_str_mv | AT ehrlichsamanthaf usingaconsumerbasedwearableactivitytrackerforphysicalactivitygoalsettingandmeasuringstepsinpregnantwomenwithgestationaldiabetesmellitusexploringacceptanceandvalidity AT maplesjillm usingaconsumerbasedwearableactivitytrackerforphysicalactivitygoalsettingandmeasuringstepsinpregnantwomenwithgestationaldiabetesmellitusexploringacceptanceandvalidity AT barrosocristinas usingaconsumerbasedwearableactivitytrackerforphysicalactivitygoalsettingandmeasuringstepsinpregnantwomenwithgestationaldiabetesmellitusexploringacceptanceandvalidity AT brownkathleenc usingaconsumerbasedwearableactivitytrackerforphysicalactivitygoalsettingandmeasuringstepsinpregnantwomenwithgestationaldiabetesmellitusexploringacceptanceandvalidity AT bassettdavidr usingaconsumerbasedwearableactivitytrackerforphysicalactivitygoalsettingandmeasuringstepsinpregnantwomenwithgestationaldiabetesmellitusexploringacceptanceandvalidity AT zitenikkib usingaconsumerbasedwearableactivitytrackerforphysicalactivitygoalsettingandmeasuringstepsinpregnantwomenwithgestationaldiabetesmellitusexploringacceptanceandvalidity AT fortnerkimberlyb usingaconsumerbasedwearableactivitytrackerforphysicalactivitygoalsettingandmeasuringstepsinpregnantwomenwithgestationaldiabetesmellitusexploringacceptanceandvalidity |