Cargando…

Effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (HemiSPAIRE): protocol for a randomised controlled trial

INTRODUCTION: Currently National Institute for Health and Care Excellence clinical guidelines in the UK suggest that surgeons performing partial hip replacements (hemiarthroplasty) should consider using the lateral approach. Alternatively, a newer, modified posterior approach using a muscle sparing...

Descripción completa

Detalles Bibliográficos
Autores principales: Price, Anna, Ball, Susan, Rhodes, Shelley, Wickins, Robert, Gordon, Elizabeth, Aylward, Alex, Cockcroft, Emma, Morgan-Trimmer, Sarah, Powell, Roy, Timperley, John, Charity, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8190059/
https://www.ncbi.nlm.nih.gov/pubmed/34103316
http://dx.doi.org/10.1136/bmjopen-2020-045652
_version_ 1783705613832814592
author Price, Anna
Ball, Susan
Rhodes, Shelley
Wickins, Robert
Gordon, Elizabeth
Aylward, Alex
Cockcroft, Emma
Morgan-Trimmer, Sarah
Powell, Roy
Timperley, John
Charity, John
author_facet Price, Anna
Ball, Susan
Rhodes, Shelley
Wickins, Robert
Gordon, Elizabeth
Aylward, Alex
Cockcroft, Emma
Morgan-Trimmer, Sarah
Powell, Roy
Timperley, John
Charity, John
author_sort Price, Anna
collection PubMed
description INTRODUCTION: Currently National Institute for Health and Care Excellence clinical guidelines in the UK suggest that surgeons performing partial hip replacements (hemiarthroplasty) should consider using the lateral approach. Alternatively, a newer, modified posterior approach using a muscle sparing technique named ‘Save Piriformis and Internus, Repairing Externus’ (SPAIRE) can be used leaving the major muscles intact. This randomised controlled trial (RCT) aims to compare the SPAIRE approach to the standard lateral approach, to determine if it allows patients to mobilise better and experience improved function after surgery. METHODS AND ANALYSIS: HemiSPAIRE is a two-arm, assessor-blinded, definitive pragmatic RCT with nested pilot and qualitative studies. Two hundred and twenty-eight participants with displaced intracapsular fractures requiring hip hemiarthroplasty will be individually randomised 1:1 to either the SPAIRE, or control (standard lateral approach) surgical procedure. Outcomes will be assessed at postoperative day 3 (POD3) and 120 (POD120). The primary outcome measure will be level of function and mobility using the Oxford Hip Score at POD120. Secondary outcomes include: De Morton Mobility Index (DEMMI), Cumulated Ambulatory Score and Numeric Pain Rating Scale (NPRS) at POD3; DEMMI, NPRS and EQ-5D-5L at POD120, complications, acute and total length of hospital stay, and mortality. Primary analysis will be on an intention-to-treat basis. Participant experiences of the impact of surgery and recovery period will be examined via up to 20 semi-structured telephone interviews. ETHICS AND DISSEMINATION: The protocol has been approved by Yorkshire and the Humber—Bradford Leeds Research Ethics Committee. Recruitment commenced in November 2019. Findings will be disseminated via research articles in peer-reviewed journals, presentations at conferences, public involvement events, patient groups and media releases. A summary of the trial findings will be shared with participants at the end of the study. TRIAL REGISTRATION NUMBER: NCT04095611.
format Online
Article
Text
id pubmed-8190059
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-81900592021-06-25 Effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (HemiSPAIRE): protocol for a randomised controlled trial Price, Anna Ball, Susan Rhodes, Shelley Wickins, Robert Gordon, Elizabeth Aylward, Alex Cockcroft, Emma Morgan-Trimmer, Sarah Powell, Roy Timperley, John Charity, John BMJ Open Surgery INTRODUCTION: Currently National Institute for Health and Care Excellence clinical guidelines in the UK suggest that surgeons performing partial hip replacements (hemiarthroplasty) should consider using the lateral approach. Alternatively, a newer, modified posterior approach using a muscle sparing technique named ‘Save Piriformis and Internus, Repairing Externus’ (SPAIRE) can be used leaving the major muscles intact. This randomised controlled trial (RCT) aims to compare the SPAIRE approach to the standard lateral approach, to determine if it allows patients to mobilise better and experience improved function after surgery. METHODS AND ANALYSIS: HemiSPAIRE is a two-arm, assessor-blinded, definitive pragmatic RCT with nested pilot and qualitative studies. Two hundred and twenty-eight participants with displaced intracapsular fractures requiring hip hemiarthroplasty will be individually randomised 1:1 to either the SPAIRE, or control (standard lateral approach) surgical procedure. Outcomes will be assessed at postoperative day 3 (POD3) and 120 (POD120). The primary outcome measure will be level of function and mobility using the Oxford Hip Score at POD120. Secondary outcomes include: De Morton Mobility Index (DEMMI), Cumulated Ambulatory Score and Numeric Pain Rating Scale (NPRS) at POD3; DEMMI, NPRS and EQ-5D-5L at POD120, complications, acute and total length of hospital stay, and mortality. Primary analysis will be on an intention-to-treat basis. Participant experiences of the impact of surgery and recovery period will be examined via up to 20 semi-structured telephone interviews. ETHICS AND DISSEMINATION: The protocol has been approved by Yorkshire and the Humber—Bradford Leeds Research Ethics Committee. Recruitment commenced in November 2019. Findings will be disseminated via research articles in peer-reviewed journals, presentations at conferences, public involvement events, patient groups and media releases. A summary of the trial findings will be shared with participants at the end of the study. TRIAL REGISTRATION NUMBER: NCT04095611. BMJ Publishing Group 2021-06-08 /pmc/articles/PMC8190059/ /pubmed/34103316 http://dx.doi.org/10.1136/bmjopen-2020-045652 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY. Published by BMJ. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/.
spellingShingle Surgery
Price, Anna
Ball, Susan
Rhodes, Shelley
Wickins, Robert
Gordon, Elizabeth
Aylward, Alex
Cockcroft, Emma
Morgan-Trimmer, Sarah
Powell, Roy
Timperley, John
Charity, John
Effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (HemiSPAIRE): protocol for a randomised controlled trial
title Effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (HemiSPAIRE): protocol for a randomised controlled trial
title_full Effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (HemiSPAIRE): protocol for a randomised controlled trial
title_fullStr Effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (HemiSPAIRE): protocol for a randomised controlled trial
title_full_unstemmed Effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (HemiSPAIRE): protocol for a randomised controlled trial
title_short Effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (HemiSPAIRE): protocol for a randomised controlled trial
title_sort effects of a modified muscle sparing posterior technique in hip hemiarthroplasty for displaced intracapsular fractures on postoperative function compared to a standard lateral approach (hemispaire): protocol for a randomised controlled trial
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8190059/
https://www.ncbi.nlm.nih.gov/pubmed/34103316
http://dx.doi.org/10.1136/bmjopen-2020-045652
work_keys_str_mv AT priceanna effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT ballsusan effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT rhodesshelley effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT wickinsrobert effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT gordonelizabeth effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT aylwardalex effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT cockcroftemma effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT morgantrimmersarah effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT powellroy effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT timperleyjohn effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial
AT charityjohn effectsofamodifiedmusclesparingposteriortechniqueinhiphemiarthroplastyfordisplacedintracapsularfracturesonpostoperativefunctioncomparedtoastandardlateralapproachhemispaireprotocolforarandomisedcontrolledtrial