Cargando…
Sensitive Formaldehyde Detection with QCM Sensor Based on PAAm/MWCNTs and PVAm/MWCNTs†
[Image: see text] Two formaldehyde detection methods are proposed by applying composite film quartz crystal microbalance (QCM) sensors. QCM sensor coated with PAAm/MWCNTs and PVAm/MWCNTs shows excellent characteristics of lower limit and high sensitivity. The lower limit of PVAm/MWCNTs is 0.5 ppm, a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8190811/ https://www.ncbi.nlm.nih.gov/pubmed/34124425 http://dx.doi.org/10.1021/acsomega.0c05987 |
_version_ | 1783705760370262016 |
---|---|
author | Feng, Lihui Feng, Liying Li, Qi Cui, Jianmin Guo, Junqiang |
author_facet | Feng, Lihui Feng, Liying Li, Qi Cui, Jianmin Guo, Junqiang |
author_sort | Feng, Lihui |
collection | PubMed |
description | [Image: see text] Two formaldehyde detection methods are proposed by applying composite film quartz crystal microbalance (QCM) sensors. QCM sensor coated with PAAm/MWCNTs and PVAm/MWCNTs shows excellent characteristics of lower limit and high sensitivity. The lower limit of PVAm/MWCNTs is 0.5 ppm, and its detection sensitivity is 0.74 ppm/Hz. Upon working at different concentrations of formaldehyde and fabricating in different proportions, the reuse performance, gas selectivity, and response at room temperature show contrasting results. The main advantages of the two sensors presented are fast reaction, low cost, and easy manufacture. Compared to other formaldehyde sensors based on QCM, the PAAm/MWCNT- and PVAm/MWCNT-coated QCM sensors are able to concurrently show excellent selectivity, reuse performance, and high sensitivity, which is of great significance to detect the environmental quality. |
format | Online Article Text |
id | pubmed-8190811 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-81908112021-06-11 Sensitive Formaldehyde Detection with QCM Sensor Based on PAAm/MWCNTs and PVAm/MWCNTs† Feng, Lihui Feng, Liying Li, Qi Cui, Jianmin Guo, Junqiang ACS Omega [Image: see text] Two formaldehyde detection methods are proposed by applying composite film quartz crystal microbalance (QCM) sensors. QCM sensor coated with PAAm/MWCNTs and PVAm/MWCNTs shows excellent characteristics of lower limit and high sensitivity. The lower limit of PVAm/MWCNTs is 0.5 ppm, and its detection sensitivity is 0.74 ppm/Hz. Upon working at different concentrations of formaldehyde and fabricating in different proportions, the reuse performance, gas selectivity, and response at room temperature show contrasting results. The main advantages of the two sensors presented are fast reaction, low cost, and easy manufacture. Compared to other formaldehyde sensors based on QCM, the PAAm/MWCNT- and PVAm/MWCNT-coated QCM sensors are able to concurrently show excellent selectivity, reuse performance, and high sensitivity, which is of great significance to detect the environmental quality. American Chemical Society 2021-05-24 /pmc/articles/PMC8190811/ /pubmed/34124425 http://dx.doi.org/10.1021/acsomega.0c05987 Text en © 2021 The Authors. Published by American Chemical Society Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Feng, Lihui Feng, Liying Li, Qi Cui, Jianmin Guo, Junqiang Sensitive Formaldehyde Detection with QCM Sensor Based on PAAm/MWCNTs and PVAm/MWCNTs† |
title | Sensitive Formaldehyde Detection with QCM Sensor Based
on PAAm/MWCNTs and PVAm/MWCNTs† |
title_full | Sensitive Formaldehyde Detection with QCM Sensor Based
on PAAm/MWCNTs and PVAm/MWCNTs† |
title_fullStr | Sensitive Formaldehyde Detection with QCM Sensor Based
on PAAm/MWCNTs and PVAm/MWCNTs† |
title_full_unstemmed | Sensitive Formaldehyde Detection with QCM Sensor Based
on PAAm/MWCNTs and PVAm/MWCNTs† |
title_short | Sensitive Formaldehyde Detection with QCM Sensor Based
on PAAm/MWCNTs and PVAm/MWCNTs† |
title_sort | sensitive formaldehyde detection with qcm sensor based
on paam/mwcnts and pvam/mwcnts† |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8190811/ https://www.ncbi.nlm.nih.gov/pubmed/34124425 http://dx.doi.org/10.1021/acsomega.0c05987 |
work_keys_str_mv | AT fenglihui sensitiveformaldehydedetectionwithqcmsensorbasedonpaammwcntsandpvammwcnts AT fengliying sensitiveformaldehydedetectionwithqcmsensorbasedonpaammwcntsandpvammwcnts AT liqi sensitiveformaldehydedetectionwithqcmsensorbasedonpaammwcntsandpvammwcnts AT cuijianmin sensitiveformaldehydedetectionwithqcmsensorbasedonpaammwcntsandpvammwcnts AT guojunqiang sensitiveformaldehydedetectionwithqcmsensorbasedonpaammwcntsandpvammwcnts |